| Literature DB >> 24255873 |
Abstract
OBJECTIVES: The objective of this research is to find the factors associated with tinnitus masker from the literature, and by using the large amount of audiology data available from a large NHS (National Health Services, UK) hearing aid clinic. The factors evaluated were hearing impairment, age, gender, hearing aid type, mould and clinical comments.Entities:
Keywords: Age; Audiogram; Gender; ITE (in the ear)/BTE (behind the ear) hearing aids; Masker; Mould; Tinnitus
Year: 2013 PMID: 24255873 PMCID: PMC3830003 DOI: 10.1186/2193-1801-2-595
Source DB: PubMed Journal: Springerplus ISSN: 2193-1801
Class exemplars of each cluster of right ear air conduction frequencies for records recording the presence of tinnitus with or without a masker
| ac250 | ac500 | ac1K | ac2K | ac4K | ac8K | |
|---|---|---|---|---|---|---|
| C1 | 62.34 | 62.57 | 63.55 | 67.34 | 77.57 | 83.50 |
| C2 | 21.17 | 17.66 | 17.09 | 20.27 | 34.57 | 42.50 |
Class exemplars of each cluster of right ear air conduction frequencies for comments text
| ac250 | ac500 | ac1K | ac2K | ac4K | ac8K | |
|---|---|---|---|---|---|---|
| C1 | 73.66 | 73.00 | 74.99 | 80.48 | 91.08 | 108.21 |
| C2 | 35.17 | 33.56 | 35.87 | 43.26 | 55.90 | 66.50 |
Observed and expected frequencies for right ear tinnitus with/without masker
| Tinnitus | Cluster 1 | Cluster 2 | Row total |
|---|---|---|---|
| With masker | 40 | 391 | 431 |
| (65.58) | (365.42) | ||
| [654.27] | [654.27] | ||
| Without masker | 133 | 573 | 706 |
| (107.42) | (598.58) | ||
| [654.27] | [654.27] | ||
| Column Total | 173 | 964 | 1137 |
Overall
| Fields | Overall | Degrees of freedom (df) | P |
|---|---|---|---|
| Tinnitus with or without masker | 18.95 | 1 | P < 0.001 |
| Comments text | 4243.87 | 668 | P < 0.001 |
Clusters for the records with tinnitus with or without masker field with positive and negative keywords
| Positive keywords | Negative keywords | |
|---|---|---|
| C1 | Not found | Tinnitus with masker |
| C2 | Not found | Not found |
Clusters for the records with text field (comments text) with positive and negative keywords
| Positive keywords | Negative keywords | |
|---|---|---|
| C1 | audio, mould, be34, be52, be36, unmask, be54, sil, ref, tsa, gp, ca, OTHERS, rt, suitabl, be201 | masker, rev, tinnitu, appt, fta, help, review, aid, further, nfa, progress, 2000, ok, canc, counsel, cope, 2001, dna |
| C2 | masker, rev, tinnitu, appt, fta, help, review, aid, further, nfa | audio, mould, be34, be52, be36, unmask, be54, sil, ref |
Overall with tinnitus with/without masker
| Fields | Overall | Degrees of freedom (df) | P |
|---|---|---|---|
| Age | 11.31 | 1 | P < 0.001 |
| Comments text | 416.49 | 83 | P < 0.001 |
| Gender | 0.02 | 1 | P = 0.8875 |
| BTE/ITE aid | 17.16 | 1 | P < 0.001 |
| Mould | 93.16 | 2 | P < 0.001 |
Categories with positive and negative keywords in records with a tinnitus with/without masker
| Positive keywords | Negative keywords | |
|---|---|---|
| Age < =55 | * | * |
| Not found | Not found | |
| Age > 55 | * | * |
| Not found | Not found | |
| Tinnitus without masker | ** | ** |
| counsel, tinnitu | Not found | |
| *** | *** | |
| Not found | Not found | |
| **** | **** | |
| 2107 | N8 | |
| Tinnitus with masker | ** | ** |
| masker | counsel, tinnitu | |
| *** | *** | |
| Not found | BTE | |
| **** | **** | |
| N8 | 2107 | |
| Male | * | * |
| Not found | Not found | |
| Female | * | * |
| Not found | Not found |
Yule’s Q for tinnitus with/without masker and mild-to-moderate hearing loss cluster/normal or near-normal hearing loss cluster
| Tinnitus | Severe hearing loss cluster (P) | Normal or near-normal hearing loss cluster (P) | Severe hearing loss cluster (A) | Normal or near-normal hearing loss cluster (A) | Yule’s Q |
|---|---|---|---|---|---|
| With masker | 40 | 391 | 133 | 573 | −0.39 |
| Without masker | 133 | 573 | 40 | 391 | 0.39 |
Yule’s Q for ITE/BTE aid and tinnitus with/without masker
| Hearing aid type | With masker (P) | Without masker (P) | With masker (A) | Without masker (A) | Yule’s Q |
|---|---|---|---|---|---|
| ITE | 67 | 101 | 15 | 82 | 0.57 |
| BTE | 15 | 82 | 67 | 101 | −0.57 |
Yule’s Q for tinnitus with/without masker and age
| Tinnitus | Age < =55 (P) | Age > 55 (P) | Age < =55 (A) | Age > 55 (A) | Yule’s Q |
|---|---|---|---|---|---|
| With masker | 240 | 182 | 328 | 377 | 0.20 |
| Without masker | 328 | 377 | 240 | 182 | −0.20 |
Yule’s Q for tinnitus with/without masker and gender
| Tinnitus | Male (P) | Female (P) | Male (A) | Female (A) | Yule’s Q |
|---|---|---|---|---|---|
| With masker | 246 | 206 | 396 | 337 | 0.01 |
| Without masker | 396 | 337 | 246 | 206 | −0.01 |
Support and confidence for ITE/BTE aid and tinnitus with/without masker
| Tinnitus with masker | Tinnitus without masker | |||
|---|---|---|---|---|
| Hearing aid type | Support | Confidence | Support | Confidence |
| ITE | 0.25 | 0.82 | 0.38 | 0.55 |
| BTE | 0.06 | 0.18 | 0.31 | 0.45 |
Support and confidence for tinnitus with/without masker and age
| Age < =55 | Age > 55 | |||
|---|---|---|---|---|
| Tinnitus | Support | Confidence | Support | Confidence |
| With masker | 0.21 | 0.42 | 0.16 | 0.33 |
| Without masker | 0.29 | 0.58 | 0.33 | 0.67 |
Support and confidence for tinnitus with/without masker and gender
| Male | Female | |||
|---|---|---|---|---|
| Tinnitus | Support | Confidence | Support | Confidence |
| With masker | 0.21 | 0.38 | 0.17 | 0.38 |
| Without masker | 0.33 | 0.62 | 0.28 | 0.62 |
Candidate variables with their reason for association with research question: factors influencing the choice of tinnitus masker
| Variables found | Reason for choosing the variable(s) |
|---|---|
| Audiograms | Tinnitus maskers were found atypical with moderate to severe hearing loss cluster of audiograms in Table |
| Gender | Yule’s Q found very weak positive association of males with tinnitus masker in Table |
| ITE/BTE aid | Chi-squared test found BTE aids atypical of tinnitus maskers in Table |
| Age | Yule’s Q found weak positive association of tinnitus masker with Age < =55 in Table |
| Mould | Mould was found associated with tinnitus with masker using chi-squared test in Table |