Literature DB >> 24240352

Intraocular lens power calculation: a challenging case.

Nicola Rosa1, Maddalena De Bernardo, Stefania Iaccarino, Michela Cennamo.   

Abstract

PURPOSE: To highlight different methods in calculating intraocular lens (IOL) power in the case of undetectable keratometric (K) readings. CASE REPORT: A 54-year-old woman was referred to us for cataract surgery in her left eye. The slit lamp examination revealed the presence of corneal scars that did not allow us to take reliable K readings. To calculate them, the following regression formula was used: K= Rx-42.613/-0.0424*AL. The IOL power calculation was performed aiming at a postoperative error = -0.5 diopters. One month after surgery, the uncorrected visual acuity was 20/100 and the best spectacles corrected visual acuity was 20/25 with +1.0 -4 × 180 (-1.0 diopter spherical equivalent).
CONCLUSIONS: This seems to be a reliable method to calculate the IOL power when K readings are undetectable, but to make a definitive statement, prospective studies are needed.

Entities:  

Mesh:

Year:  2014        PMID: 24240352     DOI: 10.1097/OPX.0000000000000127

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

Review 1.  IOL power calculation after corneal refractive surgery.

Authors:  Maddalena De Bernardo; Luigi Capasso; Luisa Caliendo; Francesco Paolercio; Nicola Rosa
Journal:  Biomed Res Int       Date:  2014-07-21       Impact factor: 3.411

2.  Axial Length Shortening After Cataract Surgery: New Approach to Solve the Question.

Authors:  Maddalena De Bernardo; Giulio Salerno; Palmiro Cornetta; Nicola Rosa
Journal:  Transl Vis Sci Technol       Date:  2018-12-27       Impact factor: 3.283

3.  Calculation of the Real Corneal Refractive Power after Photorefractive Keratectomy Using Pentacam, When Only the Preoperative Refractive Error is Known.

Authors:  Maddalena De Bernardo; Maria Borrelli; Roberto Imparato; Nicola Rosa
Journal:  J Ophthalmol       Date:  2020-04-01       Impact factor: 1.909

4.  Intraocular Pressure Measurements in Standing Position with a Rebound Tonometer.

Authors:  Maddalena De Bernardo; Maria Borrelli; Giovanni Cembalo; Nicola Rosa
Journal:  Medicina (Kaunas)       Date:  2019-10-18       Impact factor: 2.430

5.  Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy.

Authors:  Maddalena De Bernardo; Palmiro Cornetta; Giuseppe Marotta; Giulio Salerno; Ilaria De Pascale; Nicola Rosa
Journal:  J Int Med Res       Date:  2019-12-26       Impact factor: 1.671

6.  Calculation of Unknown Preoperative K Readings in Postrefractive Surgery Patients.

Authors:  Nicola Rosa; Maddalena De Bernardo; Maria Borrelli
Journal:  J Ophthalmol       Date:  2018-02-11       Impact factor: 1.909

7.  Biometric Parameters and Corneal Astigmatism: Differences Between Male and Female Eyes.

Authors:  Maddalena De Bernardo; Lucio Zeppa; Lucia Zeppa; Palmiro Cornetta; Livio Vitiello; Nicola Rosa
Journal:  Clin Ophthalmol       Date:  2020-02-28