Literature DB >> 24238711

A novel stop-flow two-dimensional liquid chromatography-mass spectrometry method for lipid analysis.

Shuangyuan Wang1, Jia Li, Xianzhe Shi, Lizhen Qiao, Xin Lu, Guowang Xu.   

Abstract

A novel on-line two dimensional liquid chromatography (2D LC) based on stop-flow mode coupled with electrospray ionization mass spectrometry (ESI-MS) method was established to separate lipids in human plasma. Hydrophilic interaction liquid chromatography (HILIC) in the first dimension and reversed-phase liquid chromatography (RP LC) in the second dimension were used to separate the lipids into six fractions based on their polar head groups and further into peaks based on aliphatic chains, respectively. A new stop-flow interface with a trap column and an extra make-up flow was designed to construct this system and trap the components eluted from the first dimension. Moreover, the same length of analytical columns and similar flow rates were used in the first and second dimensions. Therefore, the new stop-flow 2D LC system can avoid the sensitivity decrease caused by the dilution effect, which is the shortcoming of comprehensive 2D LC. Three hundred and seventy-two lipids were identified from plasma extract using this 2D LC coupled with ESI-MS in positive mode, and 88 more lipids were detected than one-dimensional RP LC analysis. Peak capacity of this stop-flow 2D LC was 415, which is similar to that of comprehensive 2D LC. The linearity, repeatability and sensitivity of this method were satisfactory, which demonstrated that this method was also suitable for quantitative analysis. All these results indicated that this on-line 2D LC method is powerful for qualitative and quantitative analysis of complex lipids.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Lipid; MS; On-line; Stop-flow; Two-dimensional liquid chromatography

Mesh:

Substances:

Year:  2013        PMID: 24238711     DOI: 10.1016/j.chroma.2013.10.069

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  8 in total

1.  Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis.

Authors:  Mónica Narváez-Rivas; Ngoc Vu; Guan-Yuan Chen; Qibin Zhang
Journal:  Anal Chim Acta       Date:  2016-12-10       Impact factor: 6.558

2.  Integrating comprehensive two-dimensional gas chromatography mass spectrometry and parallel two-dimensional liquid chromatography mass spectrometry for untargeted metabolomics.

Authors:  Md Aminul Islam Prodhan; Biyun Shi; Ming Song; Liqing He; Fang Yuan; Xinmin Yin; Patrick Bohman; Craig J McClain; Xiang Zhang
Journal:  Analyst       Date:  2019-06-13       Impact factor: 4.616

3.  Characterization of complex lipid mixtures in contaminant exposed JEG-3 cells using liquid chromatography and high-resolution mass spectrometry.

Authors:  Eva Gorrochategui; Josefina Casas; Elisabet Pérez-Albaladejo; Olga Jáuregui; Cinta Porte; Sílvia Lacorte
Journal:  Environ Sci Pollut Res Int       Date:  2014-06-28       Impact factor: 4.223

Review 4.  Assessment of Isoprostanes in Human Plasma: Technical Considerations and the Use of Mass Spectrometry.

Authors:  Yiu Yiu Lee; Jean-Marie Galano; Camille Oger; Claire Vigor; Reversat Guillaume; Jérôme Roy; Jean-Yves Le Guennec; Thierry Durand; Jetty Chung-Yung Lee
Journal:  Lipids       Date:  2016-09-26       Impact factor: 1.880

5.  Comprehensive analysis of lipids in biological systems by liquid chromatography-mass spectrometry.

Authors:  Tomas Cajka; Oliver Fiehn
Journal:  Trends Analyt Chem       Date:  2014-10-01       Impact factor: 12.296

Review 6.  Mass spectrometry methodology in lipid analysis.

Authors:  Lin Li; Juanjuan Han; Zhenpeng Wang; Jian'an Liu; Jinchao Wei; Shaoxiang Xiong; Zhenwen Zhao
Journal:  Int J Mol Sci       Date:  2014-06-11       Impact factor: 5.923

7.  Evaluation of LC-MS and LC×LC-MS in analysis of zebrafish embryo samples for comprehensive lipid profiling.

Authors:  Mengmeng Xu; Jessica Legradi; Pim Leonards
Journal:  Anal Bioanal Chem       Date:  2020-04-29       Impact factor: 4.142

Review 8.  Recent advances in analytical strategies for mass spectrometry-based lipidomics.

Authors:  Tianrun Xu; Chunxiu Hu; Qiuhui Xuan; Guowang Xu
Journal:  Anal Chim Acta       Date:  2020-09-30       Impact factor: 6.558

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.