Use of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter.

Andrew Wollowitz1, Polly E Bijur, David Esses, E John Gallagher.   

Abstract

OBJECTIVES: Hemolysis of blood samples drawn in the emergency department (ED) is a common problem that can interfere with timely diagnosis and appropriate treatment. The objective of this study was to identify the smallest number of remediable factors that independently increases the risk of hemolysis to design an effective strategy to address this issue.
METHODS: This was a prospective, observational, cross-sectional study of blood specimens obtained by ED staff in an urban, academic, adult ED in a tertiary care center. The staff member who drew the specimen recorded data on a standardized data collection instrument about device (intravenous [IV] catheter or butterfly needle), needle size, anatomic site, fullness of collection tube, tourniquet time, and difficulty of venipuncture. Specimens were sent to the laboratory by a vacuum-powered tube system. A standard automated process that measures free hemoglobin was used to identify hemolysis. A multivariable logistic regression and a tabular analysis stratified by device were performed. Ninety-five percent confidence intervals (CIs) were calculated around the odds ratios (ORs) and around the difference between hemolysis rates.
RESULTS: Data were collected on 5,118 blood specimens. There were 4,513 specimens with complete data on all characteristics of the blood draw included in the analyses. The overall hemolysis rate was 12.5% (95% CI = 11.6% to 13.5%), 14.6% in blood drawn from IV catheters and 2.7% from butterfly needles (difference = 11.9%; 95% CI = 10.2% to 13.4%). Device was the strongest independent predictor of hemolysis (OR = 7.7; 95% CI = 4.9 to 12.0). In specimens drawn by IV catheter, hemolysis was significantly higher when blood was drawn from locations other than the antecubital fossa, with small-gauge catheters, collection tubes ≤ half full, tourniquet time ≥ 1 minute, and difficult venipuncture. In contrast, none of these factors was associated with hemolysis when blood was drawn by butterfly needle.
CONCLUSIONS: The device used to collect blood was the strongest independent predictor of hemolysis in blood samples drawn in the ED in this study. This finding suggests that the most effective strategy to reduce the rate of hemolysis in the ED is to use butterfly needles for phlebotomy rather than IV catheters.
© 2013 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2013        PMID: 24238318     DOI: 10.1111/acem.12245

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  8 in total

Review 1.  Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review.

Authors:  Euan J McCaughey; Elia Vecellio; Rebecca Lake; Ling Li; Leslie Burnett; Douglas Chesher; Stephen Braye; Mark Mackay; Stephanie Gay; Tony C Badrick; Johanna I Westbrook; Andrew Georgiou
Journal:  Clin Biochem Rev       Date:  2016-12

Review 2.  Phlebotomy, a bridge between laboratory and patient.

Authors:  Cristiano Ialongo; Sergio Bernardini
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

3.  Repeated Blood Collection from Tail Vein of Non-Anesthetized Rats with a Vacuum Blood Collection System.

Authors:  Wusong Zou; Yanqun Yang; Ye Gu; Pengfei Zhu; Mingjing Zhang; Zhong Cheng; Xiaoyan Liu; Yijun Yu; Xiaohong Peng
Journal:  J Vis Exp       Date:  2017-12-10       Impact factor: 1.355

4.  ACVIM consensus statement on the diagnosis of immune-mediated hemolytic anemia in dogs and cats.

Authors:  Oliver A Garden; Linda Kidd; Angela M Mexas; Yu-Mei Chang; Unity Jeffery; Shauna L Blois; Jonathan E Fogle; Amy L MacNeill; George Lubas; Adam Birkenheuer; Simona Buoncompagni; Julien R S Dandrieux; Antonio Di Loria; Claire L Fellman; Barbara Glanemann; Robert Goggs; Jennifer L Granick; Dana N LeVine; Claire R Sharp; Saralyn Smith-Carr; James W Swann; Balazs Szladovits
Journal:  J Vet Intern Med       Date:  2019-02-26       Impact factor: 3.333

Review 5.  Errors within the total laboratory testing process, from test selection to medical decision-making - A review of causes, consequences, surveillance and solutions.

Authors:  Cornelia Mrazek; Giuseppe Lippi; Martin H Keppel; Thomas K Felder; Hannes Oberkofler; Elisabeth Haschke-Becher; Janne Cadamuro
Journal:  Biochem Med (Zagreb)       Date:  2020-06-15       Impact factor: 2.313

6.  Evaluation of a new venous catheter blood draw device and its impact on specimen hemolysis rates.

Authors:  Ruth Natali; Cara Wand; Kelly Doyle; Jaime H Noguez
Journal:  Pract Lab Med       Date:  2018-01-04

7.  The effect of blood sampling and preanalytical processing on human N-glycome.

Authors:  Tereza Dědová; Detlef Grunow; Kai Kappert; Dagmar Flach; Rudolf Tauber; Véronique Blanchard
Journal:  PLoS One       Date:  2018-07-11       Impact factor: 3.240

8.  Reverse pseudohyperkalemia is more than leukocytosis: a retrospective study.

Authors:  Osama El Shamy; Joshua L Rein; Siddhartha Kattamanchi; Jaime Uribarri; Joseph A Vassalotti
Journal:  Clin Kidney J       Date:  2020-09-07