Literature DB >> 24238310

Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

Marcio Vivan Cardoso1, Katleen Vandamme1, Amol Chaudhari1, Judith De Rycker1, Bart Van Meerbeek2, Ignace Naert1, Joke Duyck1.   

Abstract

PURPOSE: The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model.
MATERIALS AND METHODS: Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed.
RESULTS: An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p < .05). Concomitantly, the Aadva macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p < .05), and resulted in an overall impaired implant osseointegration at the initial healing stage (total implant length; 1-month healing; p < .05).
CONCLUSION: Although the Aadva implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  implant design; osseointegration; titanium

Mesh:

Substances:

Year:  2013        PMID: 24238310     DOI: 10.1111/cid.12178

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  Unravelling the effect of macro and microscopic design of dental implants on osseointegration: a randomised clinical study in minipigs.

Authors:  J V Ríos-Santos; A M Menjívar-Galán; M Herrero-Climent; B Ríos-Carrasco; A Fernández-Palacín; R A Perez; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2018-06-26       Impact factor: 3.896

2.  The effects of metformin on the bone filling ration around of TiAl6Va4 implants in non diabetic rats.

Authors:  Tuba Talo Yıldırım; Serkan Dündar; Alihan Bozoğlan; Tahir Karaman; Onur Evren Kahraman; Erhan Cahit Özcan
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-08

3.  An Osteotomy Tool That Preserves Bone Viability: Evaluation in Preclinical and Clinical Settings.

Authors:  Oded Bahat; Xing Yin; Stefan Holst; Ion Zabalegui; Eva Berroeta; Javier Pérez; Peter Wöhrle; Norbert Sörgel; John Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2022-04-30       Impact factor: 4.964

4.  Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.

Authors:  James Rudolph Collins; Brendha P Ogando; Houlin Hong; Wei Hou; Georgios E Romanos
Journal:  Dent J (Basel)       Date:  2022-06-16

5.  Effect of Surgical Installation of Dental Implants on Surface Topography and Its Influence on Osteoblast Proliferation.

Authors:  Helder H M Menezes; Marina M Naves; Henara L Costa; Tarsis P Barbosa; Jéssica A Ferreira; Denildo Magalhães; Elizabeth F Martinez
Journal:  Int J Dent       Date:  2018-10-17

6.  Biofunctionalization with a TGFβ-1 Inhibitor Peptide in the Osseointegration of Synthetic Bone Grafts: An In Vivo Study in Beagle Dogs.

Authors:  Andrea Cirera; Maria Cristina Manzanares; Pablo Sevilla; Monica Ortiz-Hernandez; Pablo Galindo-Moreno; Javier Gil
Journal:  Materials (Basel)       Date:  2019-09-27       Impact factor: 3.623

7.  Long-Term Clinical Outcomes of Treatment with Dental Implants with Acid Etched Surface.

Authors:  Eugenio Velasco-Ortega; Alvaro Jimenez-Guerra; Loreto Monsalve-Guil; Ivan Ortiz-Garcia; Ana I Nicolas-Silvente; Juan J Segura-Egea; Jose Lopez-Lopez
Journal:  Materials (Basel)       Date:  2020-03-27       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.