PURPOSE: The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS: Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. RESULTS: An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p < .05). Concomitantly, the Aadva macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p < .05), and resulted in an overall impaired implant osseointegration at the initial healing stage (total implant length; 1-month healing; p < .05). CONCLUSION: Although the Aadva implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment.
PURPOSE: The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS:Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. RESULTS: An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p < .05). Concomitantly, the Aadva macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p < .05), and resulted in an overall impaired implant osseointegration at the initial healing stage (total implant length; 1-month healing; p < .05). CONCLUSION: Although the Aadva implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment.
Authors: J V Ríos-Santos; A M Menjívar-Galán; M Herrero-Climent; B Ríos-Carrasco; A Fernández-Palacín; R A Perez; F J Gil Journal: J Mater Sci Mater Med Date: 2018-06-26 Impact factor: 3.896
Authors: Oded Bahat; Xing Yin; Stefan Holst; Ion Zabalegui; Eva Berroeta; Javier Pérez; Peter Wöhrle; Norbert Sörgel; John Brunski; Jill A Helms Journal: J Clin Med Date: 2022-04-30 Impact factor: 4.964
Authors: Helder H M Menezes; Marina M Naves; Henara L Costa; Tarsis P Barbosa; Jéssica A Ferreira; Denildo Magalhães; Elizabeth F Martinez Journal: Int J Dent Date: 2018-10-17
Authors: Andrea Cirera; Maria Cristina Manzanares; Pablo Sevilla; Monica Ortiz-Hernandez; Pablo Galindo-Moreno; Javier Gil Journal: Materials (Basel) Date: 2019-09-27 Impact factor: 3.623
Authors: Eugenio Velasco-Ortega; Alvaro Jimenez-Guerra; Loreto Monsalve-Guil; Ivan Ortiz-Garcia; Ana I Nicolas-Silvente; Juan J Segura-Egea; Jose Lopez-Lopez Journal: Materials (Basel) Date: 2020-03-27 Impact factor: 3.623