Literature DB >> 24236957

Transmission mode desorption electrospray ionization (TM-DESI) for simultaneous analysis of potential inorganic and organic components of radiological dispersion devices (RDDs).

Kenyon M Evans-Nguyen1, Amanda Quinto, Tiffanie Hargraves, Hilary Brown, Jennifer Speer, David Glatter.   

Abstract

Transmission mode desorption electrospray ionization (TM-DESI) coupled to an ion trap mass spectrometer capable of source collision-induced dissociation (CID) was used to completely analyze radiological dispersion device components. Source CID significantly enhanced the signal for metal ions by reducing adducts while eliminating chemical noise from background molecules through extensive fragmentation. Source CID spectra yielded reasonably accurate isotopic ratios for the metals studied. By switching the source CID on and off between scans, all major constituents in mixtures of simulated radionuclides and explosives were simultaneously observed. These results indicate that TM-DESI/ion trap technology could be a powerful on-site tool for nuclear forensics.

Entities:  

Year:  2013        PMID: 24236957     DOI: 10.1021/ac402386m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Forensic Analysis and Differentiation of Black Powder and Black Powder Substitute Chemical Signatures by Infrared Thermal Desorption-DART-MS.

Authors:  Thomas P Forbes; Jennifer R Verkouteren
Journal:  Anal Chem       Date:  2018-12-14       Impact factor: 6.986

2.  Detection of Nonvolatile Inorganic Oxidizer-Based Explosives from Wipe Collections by Infrared Thermal Desorption-Direct Analysis in Real Time Mass Spectrometry.

Authors:  Thomas P Forbes; Edward Sisco; Matthew Staymates
Journal:  Anal Chem       Date:  2018-05-07       Impact factor: 6.986

3.  DART-MS analysis of inorganic explosives using high temperature thermal desorption.

Authors:  Thomas P Forbes; Edward Sisco; Matthew Staymates; Greg Gillen
Journal:  Anal Methods       Date:  2017-05-04       Impact factor: 2.896

4.  Multistage Reactive Transmission-Mode Desorption Electrospray Ionization Mass Spectrometry.

Authors:  Kevin C Peters; Troy J Comi; Richard H Perry
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-20       Impact factor: 3.109

5.  Automatic Analyte-Ion Recognition and Background Removal for Ambient Mass-Spectrometric Data Based on Cross-Correlation.

Authors:  Yi You; Sunil P Badal; Jacob T Shelley
Journal:  J Am Soc Mass Spectrom       Date:  2019-06-03       Impact factor: 3.109

6.  Considerations for uranium isotope ratio analysis by atmospheric pressure ionization mass spectrometry.

Authors:  Thomas P Forbes; Christopher Szakal
Journal:  Analyst       Date:  2018-12-17       Impact factor: 4.616

Review 7.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.