Literature DB >> 24234568

Improved detection limits for fast atom bombardment mass spectrometry: A study of time-dependent desorption using a model pulsed bombardment ionization method.

A N Tyler1, L K Romo, M H Frey, B D Musselman, J Tamura, R B Cody.   

Abstract

Certain sample preparations for fast atom bombardment (FAB) yield an intense but brief pulse of sample ions at the onset of ionization. A model system is used to study this phenomenon. This system utilizes a conventional source of a constant flux of fast atoms and a probe that permits mechanical movement of the sample stage. This is used to simulate the effect of pulsing the atom beam. Experiments with model samples and selected ion monitoring detection show that, following bombardment initiation, sample ions are preferentially desorbed with respect to ions from the FAB matrix. Exhibition of preferential sample desorption depends upon the analyte behaving as a surfactant in the selected matrix. When used in conjunction with an array detector that permits data collection in a time-resolved manner, this system allows collection of useful mass spectra with significantly enhanced sensitivity compared to normal bombardment. When applied to the undecapeptide eledoisin (sequence pyro-EPSKDAFIGLM-NH2, MW 1187.6 Da) this novel methodology allows an improvement in detection limit of at least three to four orders of magnitude over that observed when using conventional continuous FAB and a point detector.

Entities:  

Year:  1992        PMID: 24234568     DOI: 10.1016/1044-0305(92)85005-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Tandem quadrupole Fourier-transform mass spectrometry of oligopeptides and small proteins.

Authors:  D F Hunt; J Shabanowitz; J R Yates; N Z Zhu; D H Russell; M E Castro
Journal:  Proc Natl Acad Sci U S A       Date:  1987-02       Impact factor: 11.205

2.  Liquid secondary ion time-of-flight mass spectrometry.

Authors:  J K Olthoff; J P Honovich; R J Cotter
Journal:  Anal Chem       Date:  1987-04-01       Impact factor: 6.986

3.  A NEW APPARATUS FOR MEASURING SURFACE TENSION.

Authors:  P L du Noüy
Journal:  J Gen Physiol       Date:  1919-05-20       Impact factor: 4.086

  3 in total
  2 in total

1.  Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

Authors:  R B Cody; J Tamura; J W Finch; B D Musselman
Journal:  J Am Soc Mass Spectrom       Date:  1994-03       Impact factor: 3.109

2.  Direct generation of ion beam images with a two-dimensional charge injection device.

Authors:  P R Cable; M Parker; R K Marcus; J M Pochkowski
Journal:  J Am Soc Mass Spectrom       Date:  1995-02       Impact factor: 3.109

  2 in total