Comparative analysis of several detectors for the measurement of radiation transmission and leakage from a multileaf collimator.

J M Lárraga-Gutiérrez1, O O Galván de la Cruz2, O A García-Garduño3, P Ballesteros-Zebadúa3.   

Abstract

The multileaf collimator (MLC) is the standard device used to shape radiation beams for 3-d conformal and intensity-modulated radiation therapy (IMRT). Due to the inherent properties of MLC, there is a small amount of radiation transmitted through the leaves, called radiation transmission (RT). Accurate measurements of this radiation are required to commission and validate IMRT-capable treatment planning systems because this radiation may impact the dosimetry of IMRT-calculated dose distributions. This work compares several detectors in the measurement of RT for a micro-multileaf collimation system. The results show that there are statistically significant differences in the measured RT values between detectors from 3.5 to 12.5% for the same MLC model and less than 0.2% relative to the isocentre dose for an open reference field. However, although small in magnitude, these differences may impact the dosimetry of IMRT treatment planning by up to 1.78 Gy to the healthy tissue surrounding the target for a treatment of 60 Gy in 30 fractions. By the later, these differences must be included as a source of uncertainty in IMRT dose delivery. Also, it must be established which detector offers the most reliable results in the measurement of the RT by using Monte Carlo simulation methods.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Keywords:  Film dosimetry; IMRT; Multi-leaf collimator; Solid state dosimetry

Mesh:

Year:  2013        PMID: 24231753     DOI: 10.1016/j.ejmp.2013.10.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

1.  Statistical Analysis of Treatment Planning Parameters for Prediction of Delivery Quality Assurance Failure for Helical Tomotherapy.

Authors:  Kyung Hwan Chang; Young Hyun Lee; Byung Hun Park; Min Cheol Han; Jihun Kim; Hojin Kim; Min-Seok Cho; Hyokyeong Kang; Ho Lee; Dong Wook Kim; Kwangwoo Park; Jaeho Cho; Yong Bae Kim; Jin Sung Kim; Chae-Seon Hong
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec

2.  Determination of MLC model parameters for Monaco using commercial diode arrays.

Authors:  Paul Kinsella; Laura Shields; Patrick McCavana; Brendan McClean; Brian Langan
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.