Literature DB >> 24231240

Trajectory modulated prone breast irradiation: a LINAC-based technique combining intensity modulated delivery and motion of the couch.

Benjamin Fahimian1, Victoria Yu, Kathleen Horst, Lei Xing, Dimitre Hristov.   

Abstract

PURPOSE: External beam radiation therapy (EBRT) provides a non-invasive treatment alternative for accelerated partial breast irradiation (APBI), however, limitations in achievable dose conformity of current EBRT techniques have been correlated to reported toxicity. To enhance the conformity of EBRT APBI, a technique for conventional LINACs is developed, which through combined motion of the couch, intensity modulated delivery, and a prone breast setup, enables wide-angular coronal arc irradiation of the ipsilateral breast without irradiating through the thorax and contralateral breast. METHODS AND MATERIALS: A couch trajectory optimization technique was developed to determine the trajectories that concurrently avoid collision with the LINAC and maintain the target within the MLC apertures. Inverse treatment planning was performed along the derived trajectory. The technique was experimentally implemented by programming the Varian TrueBeam™ STx in Developer Mode. The dosimetric accuracy of the delivery was evaluated by ion chamber and film measurements in phantom.
RESULTS: The resulting optimized trajectory was shown to be necessarily non-isocentric, and contain both translation and rotations of the couch. Film measurements resulted in 93% of the points in the measured two-dimensional dose maps passing the 3%/3mm Gamma criterion. Preliminary treatment plan comparison to 5-field 3D-conformal, IMRT, and VMAT demonstrated enhancement in conformity, and reduction of the normal tissue V50% and V100% parameters that have been correlated with EBRT toxicity.
CONCLUSIONS: The feasibility of wide-angular intensity modulated partial breast irradiation using motion of the couch has been demonstrated experimentally on a standard LINAC for the first time. For patients eligible for a prone setup, the technique may enable improvement of dose conformity and associated dose-volume parameters correlated with toxicity.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Accelerated partial breast irradiation (APBI); Couch motion; IMRT; Trajectory modulated arc therapy (TMAT)

Mesh:

Year:  2013        PMID: 24231240     DOI: 10.1016/j.radonc.2013.10.031

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  12 in total

1.  Dosimetric accuracy of dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) for primary brain tumours.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; Henry C Mandeville; A Rollo Moore; Liam C Welsh; Frank H Saran; James L Bedford
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

2.  Comparison of conventional and advanced radiotherapy techniques for left-sided breast cancer after breast conserving surgery.

Authors:  Yibo Xie; Daniel Bourgeois; Beibei Guo; Rui Zhang
Journal:  Med Dosim       Date:  2020-07-07       Impact factor: 1.482

3.  Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases.

Authors:  Tiago Ventura; Humberto Rocha; Brigida da Costa Ferreira; Joana Dias; Maria do Carmo Lopes
Journal:  Phys Eng Sci Med       Date:  2021-10-07

4.  The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery.

Authors:  Victoria Y Yu; Angelia Tran; Dan Nguyen; Minsong Cao; Dan Ruan; Daniel A Low; Ke Sheng
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

5.  The Influence of Treatment Position (Prone vs. Supine) on Clip Displacement, Seroma, Tumor Bed and Partial Breast Target Volumes: Comparative Study.

Authors:  Ferenc Lakosi; Akos Gulyban; Selma Ben-Mustapha Simoni; Paul Viet Nguyen; Séverine Cucchiaro; Laurence Seidel; Levente Janvary; Sophie Nicolas; Peter Vavassis; Philippe Coucke
Journal:  Pathol Oncol Res       Date:  2015-12-16       Impact factor: 3.201

6.  Verification of the delivered patient radiation dose for non-coplanar beam therapy.

Authors:  Ivan Kutuzov; Timothy Van Beek; Boyd M C McCurdy
Journal:  J Appl Clin Med Phys       Date:  2021-05-22       Impact factor: 2.102

Review 7.  Treatment techniques to reduce cardiac irradiation for breast cancer patients treated with breast-conserving surgery and radiation therapy: a review.

Authors:  Robert E Beck; Leonard Kim; Ning J Yue; Bruce G Haffty; Atif J Khan; Sharad Goyal
Journal:  Front Oncol       Date:  2014-11-14       Impact factor: 6.244

Review 8.  Critical appraisal of the role of volumetric modulated arc therapy in the radiation therapy management of breast cancer.

Authors:  Luca Cozzi; Frank Lohr; Antonella Fogliata; Davide Franceschini; Fiorenza De Rose; A R Filippi; Gabriele Guidi; Valentina Vanoni; Marta Scorsetti
Journal:  Radiat Oncol       Date:  2017-12-19       Impact factor: 3.481

9.  Commissioning and quality assurance of Dynamic WaveArc irradiation.

Authors:  Sayaka Sato; Yuki Miyabe; Kunio Takahashi; Masahiro Yamada; Mitsuhiro Nakamura; Yoshitomo Ishihara; Kenji Yokota; Shuji Kaneko; Takashi Mizowaki; Hajime Monzen; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

Review 10.  Recent developments in non-coplanar radiotherapy.

Authors:  Gregory Smyth; Philip M Evans; Jeffrey C Bamber; James L Bedford
Journal:  Br J Radiol       Date:  2019-02-01       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.