Literature DB >> 24227643

High-resolution accurate mass measurements of biomolecules using a new electrospray ionization ion cyclotron resonance mass spectrometer.

B E Winger1, S A Hofstadler, J E Bruce, H R Udseth, R D Smith.   

Abstract

A novel electrospray ionization/Fourier transform ion cyclotron resonance mass spectrometer based on a 7-T superconducting magnet was developed for high-resolution accurate mass measurements of large biomolecules. Ions formed at atmospheric pressure using electrospray ionization (ESI) were transmitted (through six differential pumping stages) to the trapped ion cell maintained below 10(-9) torr. The increased pumping speed attainable with cryopumping (> 10(5) L/s) allowed brief pressure excursions to above 10(-4) torr, with greatly enhanced trapping efficiencies and subsequent short pumpdown times, facilitating high-resolution mass measurements. A set of electromechanical shutters were also used to minimize the effect of the directed molecular beam produced by the ES1 source and were open only during ion injection. Coupled with the use of the pulsed-valve gas inlet, the trapped ion cell was generally filled to the space charge limit within 100 ms. The use of 10-25 ms ion injection times allowed mass spectra to be obtained from 4 fmol of bovine insulin (Mr 5734) and ubiquitin (Mr 8565, with resolution sufficient to easily resolve the isotopic envelopes and determine the charge states. The microheterogeneity of the glycoprotein ribonuclease B was examined, giving a measured mass of 14,898.74 Da for the most abundant peak in the isotopic envelope of the normally glycosylated protein (i.e., with five mannose and two N-acetylglucosamine residues (an error of approximately 2 ppm) and an average error of approximately 1 ppm for the higher glycosylated and various H3PO4 adducted forms of the protein. Time-domain signals lasting in excess of 80 s were obtained for smaller proteins, producing, for example, a mass resolution of more than 700,000 for the 4(+) charge state (m/z 1434) of insulin.

Entities:  

Year:  1993        PMID: 24227643     DOI: 10.1016/1044-0305(93)85018-S

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  9 in total

1.  Mass spectrometry in the integrated strategy for the structural analysis of protein variants.

Authors:  Y Wada
Journal:  Biol Mass Spectrom       Date:  1992-12

2.  Solvent-induced conformational changes of polypeptides probed by electrospray-ionization mass spectrometry.

Authors:  J A Loo; R R Loo; H R Udseth; C G Edmonds; R D Smith
Journal:  Rapid Commun Mass Spectrom       Date:  1991-03       Impact factor: 2.419

3.  Tandem mass spectrometry of very large molecules: serum albumin sequence information from multiply charged ions formed by electrospray ionization.

Authors:  J A Loo; C G Edmonds; R D Smith
Journal:  Anal Chem       Date:  1991-11-01       Impact factor: 6.986

4.  Trapping and detection of ions generated in a high magnetic field electrospray ionization fourier transform ion cyclotron resonance mass spectrometer.

Authors:  S A Hofstadler; D A Laude
Journal:  J Am Soc Mass Spectrom       Date:  1992-09       Impact factor: 3.109

5.  Structure of ubiquitin refined at 1.8 A resolution.

Authors:  S Vijay-Kumar; C E Bugg; W J Cook
Journal:  J Mol Biol       Date:  1987-04-05       Impact factor: 5.469

6.  Conformational changes in proteins probed by hydrogen-exchange electrospray-ionization mass spectrometry.

Authors:  V Katta; B T Chait
Journal:  Rapid Commun Mass Spectrom       Date:  1991-04       Impact factor: 2.419

7.  A "screened" electrostatic ion trap for enhanced mass resolution, mass accuracy, reproducibility, and upper mass limit in Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  M Wang; A G Marshall
Journal:  Anal Chem       Date:  1989-06-01       Impact factor: 6.986

8.  Stimulation of ATP-dependent proteolysis requires ubiquitin with the COOH-terminal sequence Arg-Gly-Gly.

Authors:  K D Wilkinson; T K Audhya
Journal:  J Biol Chem       Date:  1981-09-10       Impact factor: 5.157

9.  Gas-phase proton transfer reactions involving multiply charged cytochrome c ions and water under thermal conditions.

Authors:  B E Winger; K J Light-Wahl; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  1992-09       Impact factor: 3.109

  9 in total
  22 in total

1.  Electrospray ionization Fourier transform ion cyclotron resonance analysis of large polymerase chain reaction products.

Authors:  D S Wunschel; L P Tolić; B Feng; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2000-04       Impact factor: 3.109

2.  Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions.

Authors:  J E Bruce; G A Anderson; M D Brands; L Pasa-Tolic; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2000-05       Impact factor: 3.109

3.  Magnetic field focused ion accumulation for an internal bore liquid chromatography electrospray ionization Fourier transform ion cyclotron resonance mass spectrometer using a central trapping electrode

Authors: 
Journal:  J Am Soc Mass Spectrom       Date:  2000-06       Impact factor: 3.109

4.  Characterization of multipole storage assisted dissociation: implications for electrospray ionization mass spectrometry characterization of biomolecules.

Authors:  K A Sannes-Lowery; S A Hofstadler
Journal:  J Am Soc Mass Spectrom       Date:  2000-01       Impact factor: 3.109

5.  Direct mass spectrometric analysis of intact proteins of the yeast large ribosomal subunit using capillary LC/FTICR.

Authors:  Sang-Won Lee; Scott J Berger; Suzana Martinović; Ljiljana Pasa-Tolić; Gordon A Anderson; Yufeng Shen; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-04-30       Impact factor: 11.205

6.  Covalent modification of lipids and proteins in rat hepatocytes and in vitro by thioacetamide metabolites.

Authors:  Diganta Sarma; Heather Hajovsky; Yakov M Koen; Nadezhda A Galeva; Todd D Williams; Jeffrey L Staudinger; Robert P Hanzlik
Journal:  Chem Res Toxicol       Date:  2012-06-15       Impact factor: 3.739

7.  Relative information content and top-down proteomics by mass spectrometry: utility of ion/ion proton-transfer reactions in electrospray-based approaches.

Authors:  Jian Liu; Paul A Chrisman; David E Erickson; Scott A McLuckey
Journal:  Anal Chem       Date:  2007-02-01       Impact factor: 6.986

8.  Reduction of axial kinetic energy induced perturbations on observed cyclotron frequency.

Authors:  Nathan K Kaiser; Chad R Weisbrod; Brian N Webb; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2008-01-06       Impact factor: 3.109

9.  Dissociation of tetrameric ions of noncovalent streptavidin complexes formed by electrospray ionization.

Authors:  B L Schwartz; J E Bruce; G A Anderson; S A Hofstadler; A L Rockwood; R D Smith; A Chilkoti; P S Stayton
Journal:  J Am Soc Mass Spectrom       Date:  1995-06       Impact factor: 3.109

10.  Capillary electrophoresis fourier transform ion cyclotron resonance mass spectrometry with sustained off-resonance irradiation for the characterization of protein and peptide mixtures.

Authors:  S A Hofstadler; J H Wahl; R Bakhtiar; G A Anderson; J E Bruce; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  1994-10       Impact factor: 3.109