Literature DB >> 24222594

A low voltage ion transport system for external ionization fourier transform mass spectrometry.

C F Ijames1, S P Markey.   

Abstract

An efficient ion transport system that interfaces external ion sources with a commercial dual-cell Fourier transform mass spectrometry (FTMS) system so as to retain maximum experimental flexibility has been constructed. Electrostatic lenses were used for ion transfer with potentials less than 200 V to preclude discharges. Spectra were recorded by thermal ionization and by electrospray ionization. Other high pressure ionization methods can be easily added to the external ion source chamber, making this a general solution for ion transport into an FTMS system. The efficiency of ion transfer was measured to be approximately 30%. A pressure ratio of 10(5) between the external ion source chamber and the second cell has been demonstrated. The system incorporates a computer-controlled gate valve to isolate the cell regions from the external ion source chamber, permitting optimal conditions for ion injection and accumulation, and then after closing the valve, recording spectra at low pressure with high resolution. Spectra of Gramicidin S (resolution 90,000 at m/z 1164), aprotinin (resolution 410,000 at m/z 1304), and horse heart cytochrome c (resolution 50,000 at m/z 1546) are shown.

Entities:  

Year:  1994        PMID: 24222594     DOI: 10.1016/1044-0305(94)85055-0

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Fourier-transform electrospray instrumentation for tandem high-resolution mass spectrometry of large molecules.

Authors:  S C Beu; M W Senko; J P Quinn; F M Wampler; F W McLafferty
Journal:  J Am Soc Mass Spectrom       Date:  1993-07       Impact factor: 3.109

2.  Electrospray interface for liquid chromatographs and mass spectrometers.

Authors:  C M Whitehouse; R N Dreyer; M Yamashita; J B Fenn
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

3.  Ionization and mass analysis of nonvolatile compounds by particle bombardment tandem-quadrupole Fourier transform mass spectrometry.

Authors:  D F Hunt; J Shabanowitz; R T McIver; R L Hunter; J E Syka
Journal:  Anal Chem       Date:  1985-03       Impact factor: 6.986

  3 in total
  4 in total

1.  Ion trajectories in an electrostatic ion guide for external ion source fourier transform ion cyclotron resonance mass spectrometry.

Authors:  J A Marto; A G Marshall; M A May; P A Limbach
Journal:  J Am Soc Mass Spectrom       Date:  1995-10       Impact factor: 3.109

2.  Ion kinetic energy modulation for improved ion trapping in electrospray ionization fourier transform ion cyclotron resonance mass spectrometry.

Authors:  C L Hendrickson; J J Drader; D A Laude
Journal:  J Am Soc Mass Spectrom       Date:  1995-01       Impact factor: 3.109

3.  Stacked-ring electrostatic ion guide.

Authors:  S Guan; A G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  1996-01       Impact factor: 3.109

4.  Iron carboxylate oxygen-centered-triangle complexes detected during electrospray use of organic acid modifiers with a comment on the finnigan TSQ-700 electrospray inlet system.

Authors:  C F Ijames; R C Dutky; H M Fales
Journal:  J Am Soc Mass Spectrom       Date:  1995-12       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.