Literature DB >> 24216683

Theoretical comparison of the iodine quantification accuracy of two spectral CT technologies.

Hans Bornefalk, Mats Persson.   

Abstract

We compare the theoretical limits of iodine quantification for the photon counting multibin and dual energy technologies. Dual energy systems by necessity have to make prior assumptions in order to quantify iodine. We explicitly allow the multibin system to make the same assumptions and also allow them to be wrong. We isolate the effect of technology from imperfections and implementation issues by assuming both technologies to be ideal, i.e., without scattered radiation, unity detection efficiency and perfect energy response functions, and by applying the Cramér-Rao lower bound methodology to assess the quantification accuracy. When priors are wrong the maximum likelihood estimates will be biased and the mean square error of the quantification error is a more appropriate figure of merit. The evaluation assumes identical X-ray spectra for both methodologies and for that reason a sensitivity analysis is performed with regard to the assumed X-ray spectrum. We show that when iodine is quantified over regions of interest larger than 6 cm(2), multibin systems benefit by independent estimation of three basis functions. For smaller regions of interest multibin systems can increase quantification accuracy by making the same prior assumptions as dual energy systems.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24216683     DOI: 10.1109/TMI.2013.2290198

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

2.  Impact of prior information on material decomposition in dual- and multienergy computed tomography.

Authors:  Liqiang Ren; Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  J Med Imaging (Bellingham)       Date:  2019-03-14

3.  Dual-source multienergy CT with triple or quadruple x-ray beams.

Authors:  Lifeng Yu; Liqiang Ren; Zhoubo Li; Shuai Leng; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2018-07-24

4.  Simultaneous dual-contrast imaging using energy-integrating detector multi-energy CT: An in vivo feasibility study.

Authors:  Zhongxing Zhou; Liqiang Ren; Kishore Rajendran; Felix E Diehn; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2022-01-27       Impact factor: 4.071

Review 5.  An introduction to photon-counting detector CT (PCD CT) for radiologists.

Authors:  Yuko Nakamura; Toru Higaki; Shota Kondo; Ikuo Kawashita; Isao Takahashi; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2022-10-18       Impact factor: 2.701

6.  Dual-Source Multi-Energy CT with Triple or Quadruple X-ray Beams.

Authors:  Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22