Literature DB >> 24210475

A 3D lower limb musculoskeletal model for simultaneous estimation of musculo-tendon, joint contact, ligament and bone forces during gait.

Florent Moissenet1, Laurence Chèze2, Raphaël Dumas2.   

Abstract

Musculo-tendon forces and joint reaction forces are typically estimated using a two-step method, computing first the musculo-tendon forces by a static optimization procedure and then deducing the joint reaction forces from the force equilibrium. However, this method does not allow studying the interactions between musculo-tendon forces and joint reaction forces in establishing this equilibrium and the joint reaction forces are usually overestimated. This study introduces a new 3D lower limb musculoskeletal model based on a one-step static optimization procedure allowing simultaneous musculo-tendon, joint contact, ligament and bone forces estimation during gait. It is postulated that this approach, by giving access to the forces transmitted by these musculoskeletal structures at hip, tibiofemoral, patellofemoral and ankle joints, modeled using anatomically consistent kinematic models, should ease the validation of the model using joint contact forces measured with instrumented prostheses. A blinded validation based on four datasets was made under two different minimization conditions (i.e., C1 - only musculo-tendon forces are minimized, and C2 - musculo-tendon, joint contact, ligament and bone forces are minimized while focusing more specifically on tibiofemoral joint contacts). The results show that the model is able to estimate in most cases the correct timing of musculo-tendon forces during normal gait (i.e., the mean coefficient of active/inactive state concordance between estimated musculo-tendon force and measured EMG envelopes was C1: 65.87% and C2: 60.46%). The results also showed that the model is potentially able to well estimate joint contact, ligament and bone forces and more specifically medial (i.e., the mean RMSE between estimated joint contact force and in vivo measurement was C1: 1.14BW and C2: 0.39BW) and lateral (i.e., C1: 0.65BW and C2: 0.28BW) tibiofemoral contact forces during normal gait. However, the results remain highly influenced by the optimization weights that can bring to somewhat aphysiological musculo-tendon forces.
© 2013 Published by Elsevier Ltd.

Entities:  

Keywords:  Bone force; Joint contact force; Ligament force; Model validation; Musculo-tendon force; Musculoskeletal modeling; Musculoskeletal structures interaction; Static optimization

Mesh:

Year:  2013        PMID: 24210475     DOI: 10.1016/j.jbiomech.2013.10.015

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  An Open-Source Toolbox for Surrogate Modeling of Joint Contact Mechanics.

Authors:  Ilan Eskinazi; Benjamin J Fregly
Journal:  IEEE Trans Biomed Eng       Date:  2015-07-13       Impact factor: 4.538

2.  Dependence of Muscle Moment Arms on In Vivo Three-Dimensional Kinematics of the Knee.

Authors:  Alessandro Navacchia; Vasiliki Kefala; Kevin B Shelburne
Journal:  Ann Biomed Eng       Date:  2016-09-12       Impact factor: 3.934

3.  A computational framework for simultaneous estimation of muscle and joint contact forces and body motion using optimization and surrogate modeling.

Authors:  Ilan Eskinazi; Benjamin J Fregly
Journal:  Med Eng Phys       Date:  2018-03-02       Impact factor: 2.242

4.  Insertion of a pressure sensing arrayminimally affects hindfoot bone kinematics.

Authors:  Tassos Natsakis; Josefien Burg; Greta Dereymaeker; Ilse Jonkers; Jos Vander Sloten
Journal:  J Foot Ankle Res       Date:  2015-06-24       Impact factor: 2.303

5.  Knee loading in OA subjects is correlated to flexion and adduction moments and to contact point locations.

Authors:  Ali Zeighami; Raphael Dumas; Rachid Aissaoui
Journal:  Sci Rep       Date:  2021-04-21       Impact factor: 4.379

6.  The development of a segment-based musculoskeletal model of the lower limb: introducing FreeBody.

Authors:  Daniel J Cleather; Anthony M J Bull
Journal:  R Soc Open Sci       Date:  2015-06-24       Impact factor: 2.963

7.  Tenosuspension of the Reflected Head of the Rectus Femoris in Hip Arthroscopy: Description of a Portal and a Surgical Maneuver.

Authors:  Bernardo Aguilera-Bohorquez; Eduardo Gil; John Fonseca; Miguel Fernandez; Miguel Sánchez
Journal:  Arthrosc Tech       Date:  2017-07-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.