Literature DB >> 24201085

Automatic in vivo portal dosimetry of all treatments.

I Olaciregui-Ruiz, R Rozendaal, B Mijnheer, M van Herk, A Mans.   

Abstract

At our institution EPID (electronic portal imaging device) dosimetry is routinely applied to perform in vivo dose verification of all patient treatments with curative intent since January 2008. The major impediment of the method has been the amount of work required to produce and inspect the in vivo dosimetry reports (a time-consuming and labor-intensive process). In this paper we present an overview of the actions performed to implement an automated in vivo dosimetry solution clinically. We reimplemented the EPID dosimetry software and modified the acquisition software. Furthermore, we introduced new tools to periodically inspect the record-and-verify database and automatically run the EPID dosimetry software when needed. In 2012, 95% of our 3839 treatments scheduled for in vivo dosimetry were analyzed automatically (27,633 portal images of intensity-modulated radiotherapy (IMRT) fields, 5551 portal image data of VMAT arcs, and 2003 portal images of non-IMRT fields). The in vivo dosimetry verification results are available a few minutes after delivery and alerts are immediately raised when deviations outside tolerance levels are detected. After the clinical introduction of this automated solution, inspection of the detected deviations is the only remaining work. These newly developed tools are a major step forward towards full integration of in vivo EPID dosimetry in radiation oncology practice.

Entities:  

Mesh:

Year:  2013        PMID: 24201085     DOI: 10.1088/0031-9155/58/22/8253

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

2.  In vivo dosimetry in UK external beam radiotherapy: current and future usage.

Authors:  Niall D MacDougall; Michael Graveling; Vibeke N Hansen; Kevin Brownsword; Andrew Morgan
Journal:  Br J Radiol       Date:  2017-02-16       Impact factor: 3.039

3.  An evaluation of techniques for dose calculation on cone beam computed tomography.

Authors:  Valentina Giacometti; Raymond B King; Christina E Agnew; Denise M Irvine; Suneil Jain; Alan R Hounsell; Conor K McGarry
Journal:  Br J Radiol       Date:  2019-02-26       Impact factor: 3.039

4.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

5.  Improved error detection using a divided treatment plan in volume modulated arc therapy.

Authors:  Kazuo Tarutani; Masao Tanooka; Hiroshi Doi; Masayuki Fujiwara; Masaki Miyashita; Kazufumi Kagawa; Norihiko Kamikonya; Koichiro Yamakado
Journal:  Rep Pract Oncol Radiother       Date:  2019-01-21

6.  Experimental verification of a 3D in vivo dose monitoring system based on EPID.

Authors:  Xiaoyong Wang; Lixin Chen; Conghua Xie; Dajiang Wang; Gaili Chen; Zhengming Fu; Hui Liu
Journal:  Oncotarget       Date:  2017-11-30

7.  Feasibility of portal dosimetry for flattening filter-free radiotherapy.

Authors:  Robert W Chuter; Philip A Rixham; Steve J Weston; Vivian P Cosgrove
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice.

Authors:  Maria D Falco; Stefano Giancaterino; Andrea De Nicola; Nico Adorante; Ramon Gimenez De Lorenzo; Monica Di Tommaso; Annamaria Vinciguerra; Marianna Trignani; Francesca Perrotti; Albina Allajbej; Andrea Fidanzio; Francesca Greco; Mattia Grusio; Domenico Genovesi; Angelo Piermattei
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

9.  Electronic Portal Imaging Device-Based Three-Dimensional Volumetric Dosimetry for Intensity-modulated Radiotherapy Pretreatment Quality Assurance.

Authors:  Manikandan Arjunan; Sureka Chandra Sekaran; Biplab Sarkar; Saran Kumar Manavalan
Journal:  J Med Phys       Date:  2019 Jul-Sep

10.  An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm.

Authors:  Hashemi S M; Bahreyni M H; Mohammadi M; Nasseri S; Bayani S; Gholamhosseinian H; Salek R; Shahedi F; Momennezhad M
Journal:  J Biomed Phys Eng       Date:  2019-10-01
View more