Literature DB >> 24198463

Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests.

Mika Pa Laitinen1, Jari Salmela, Leona Gilbert, Risto Kaivola, Topi Tikkala, Christian Oker-Blom, Jukka Pekola, Matti Vuento.   

Abstract

A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antibodies directed against hCG. The first anti-hCG antibody was labeled with superparamagnetic particles whereas the second was immobilized as a narrow detection zone on a porous membrane. The human urine sample was mixed with superparamagnetic particles coated with the first anti-hCG antibody, and the mixture was allowed to migrate past the detection zone containing the second anti-hCG antibody. Capillary forces facilitated migration of the immune complexes along the porous membrane. The amount of superparamagnetic particle-labelled monoclonal anti-hCG bound to the detection zone was directly proportional to the amount of hCG present in the sample as detected by measuring magnetization in the detector coil. The method had a practical detection limit of 20 U/l (54 nM) of hCG per 5 μl of human urine and a linear range of three decades from 20 U/l to 10 000 U/l. In addition, the analysis was completed within less than 10 minutes. Thus, the test format should be suitable for fast detection and monitoring of a large variety of clinically important parameters and analytes.

Entities:  

Keywords:  affinity; biosensor; hCG; immunochromatography; magnetization; superparamagnetic

Year:  2009        PMID: 24198463      PMCID: PMC3781749          DOI: 10.2147/nsa.s4738

Source DB:  PubMed          Journal:  Nanotechnol Sci Appl        ISSN: 1177-8903


  14 in total

1.  Latex-based thin-layer immunoaffinity chromatography for quantitation of protein analytes.

Authors:  S Birnbaum; C Udén; C G Magnusson; S Nilsson
Journal:  Anal Biochem       Date:  1992-10       Impact factor: 3.365

2.  One-step chromatographic immunoassay for qualitative determination of choriogonadotropin in urine.

Authors:  G Osikowicz; M Beggs; P Brookhart; D Caplan; S Ching; P Eck; J Gordon; R Richerson; S Sampedro; D Stimpson
Journal:  Clin Chem       Date:  1990-09       Impact factor: 8.327

3.  Diagnosis and management of patients with suspected acute myocardial infarction.

Authors:  Bertil Lindahl
Journal:  Scand J Clin Lab Invest Suppl       Date:  2005

4.  Affinity immunosensor for milk progesterone: identification of critical parameters.

Authors:  M P Laitinen; M Vuento
Journal:  Biosens Bioelectron       Date:  1996       Impact factor: 10.618

5.  Thin-layer affinity chromatography in analysis of protein-ligand affinity.

Authors:  M P Laitinen; K M Sojakka; M Vuento
Journal:  Anal Biochem       Date:  1996-12-15       Impact factor: 3.365

6.  Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.

Authors:  H Towbin; T Staehelin; J Gordon
Journal:  Proc Natl Acad Sci U S A       Date:  1979-09       Impact factor: 11.205

7.  Immunosensor for extra-lab measurements based on liposome amplification and capillary migration.

Authors:  R A Durst; S T Siebert; S G Reeves
Journal:  Biosens Bioelectron       Date:  1993       Impact factor: 10.618

8.  Development of a combined setup for simultaneous detection of total and glycated haemoglobin content in blood samples.

Authors:  Jan Pribyl; Petr Skládal
Journal:  Biosens Bioelectron       Date:  2005-10-21       Impact factor: 10.618

9.  B-type natriuretic peptide at presentation and prognosis in patients with ST-segment elevation myocardial infarction: an ENTIRE-TIMI-23 substudy.

Authors:  Jessica L Mega; David A Morrow; James A De Lemos; Marc S Sabatine; Sabina A Murphy; Nader Rifai; C Michael Gibson; Elliott M Antman; Eugene Braunwald
Journal:  J Am Coll Cardiol       Date:  2004-07-21       Impact factor: 24.094

10.  One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma.

Authors:  S C Lou; C Patel; S Ching; J Gordon
Journal:  Clin Chem       Date:  1993-04       Impact factor: 8.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.