Literature DB >> 24191879

Prediction of postural sway velocity by foot posture index, foot size and plantar pressure values in unilateral stance.

Salih Angın1, Nursen Ilçin, Sevgi Sevi Yeşilyaprak, I Engin Simşek.   

Abstract

OBJECTIVES: This study aims to assess whether the plantar pressure, the foot posture index (FPI) and foot size can predict the postural sway velocity in terms of postural stability in unilateral stance. PATIENTS AND METHODS: A total of 236 feet of 118 participants (62 males, 56 females; mean age 22.1±3.1 years; range 18 to 36 years) were enrolled. The feet were classified as prone, normal and supine based on the FPI. Postural sway velocity during unilateral stance with eye open (US-EO) and eye closed (US-EC) condition was measured using the Balance Master. Plantar pressure for each foot was measured from 10 different areas using EMED-M pedobarography. The force-time-area (FTA) integral was calculated based on the plantar pressure values, while standardized foot size (SFS) was calculated dividing foot width by foot length. The one-way ANOVA was used to determine differences in postural sway velocity between the groups. Multiple linear regression analysis was used to evaluate the predictability of the postural sway velocity.
RESULTS: The postural sway velocities in US-EO condition were similar among three groups (p>0.05). In the US-EC condition, the highest postural sway velocity in the prone feet and lowest postural sway velocity in the supine feet were measured (p<0.05). There was a significant relationship between the postural sway velocity which was measured in the US-EC condition and SFS (β= 0.141, p<0.05), FTA integral under the hindfoot (β= -0.127, p<0.05) and FPI values (β= 0.246, p<0.05).
CONCLUSION: The predictive value of FTA integral and SFS parameters for postural sway velocity is lower in unilateral stance. The postural sway velocity is rather associated with FPI and increases by pronation of the foot.

Entities:  

Mesh:

Year:  2013        PMID: 24191879     DOI: 10.5606/ehc.2013.32

Source DB:  PubMed          Journal:  Eklem Hastalik Cerrahisi


  7 in total

1.  The Effect of Military Load Carriage on Postural Sway, Forward Trunk Lean, and Pelvic Girdle Motion.

Authors:  Eileen M Strube; Andrea Sumner; Roger Kollock; Kenneth E Games; Marie A Lackamp; Masahiro Mizutani; Joellen M Sefton
Journal:  Int J Exerc Sci       Date:  2017-01-01

2.  Feet deformities and their close association with postural stability deficits in children aged 10-15 years.

Authors:  Beata Szczepanowska-Wolowiec; Paulina Sztandera; Ireneusz Kotela; Marek Zak
Journal:  BMC Musculoskelet Disord       Date:  2019-11-13       Impact factor: 2.362

3.  Association between Foot Posture Asymmetry and Static Stability in Patients with Knee Osteoarthritis: A Case-Control Study.

Authors:  Zehua Chen; Zhen Shen; Xiangling Ye; Jiatao Wu; Huai Wu; Xuemeng Xu
Journal:  Biomed Res Int       Date:  2020-06-05       Impact factor: 3.411

4.  Prevalence of floating toe and its relationship with static postural stability in children: The Yamanashi adjunct study of the Japan Environment and Children's Study (JECS-Y).

Authors:  Taro Fujimaki; Masanori Wako; Kensuke Koyama; Naoto Furuya; Ryoji Shinohara; Sanae Otawa; Anna Kobayashi; Sayaka Horiuchi; Megumi Kushima; Zentaro Yamagata; Hirotaka Haro
Journal:  PLoS One       Date:  2021-03-24       Impact factor: 3.240

5.  Elite Tennis Players Experiencing High-Arched Supination and Cuboids Dropped Foot Syndromes in Daily Normal Gait.

Authors:  Tong-Hsien Chow; Chin-Chia Hsu
Journal:  Int J Environ Res Public Health       Date:  2022-07-22       Impact factor: 4.614

Review 6.  Techniques and Methods for Testing the Postural Function in Healthy and Pathological Subjects.

Authors:  Thierry Paillard; Frédéric Noé
Journal:  Biomed Res Int       Date:  2015-11-12       Impact factor: 3.411

7.  Controlling Posture and Vergence Eye Movements in Quiet Stance: Effects of Thin Plantar Inserts.

Authors:  A Foisy; C Gaertner; E Matheron; Z Kapoula
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.