Literature DB >> 24186321

Non-destructive evaluation of polymer coating structures on pharmaceutical pellets using full-field optical coherence tomography.

Chen Li1, J Axel Zeitler, Yue Dong, Yao-Chun Shen.   

Abstract

Full-field optical coherence tomography (FF-OCT) using a conventional light-emitting diode and a complementary metal-oxide semiconductor camera has been developed for characterising coatings on small pellet samples. A set of en-face images covering an area of 700 × 700 μm(2) was taken over a depth range of 166 μm. The three-dimensional structural information, such as the coating thickness and uniformity, was subsequently obtained by analysis of the recorded en-face images. Drug-loaded pharmaceutical sustained-release pellets with two coating layers and of a sub-millimetre diameter were studied to demonstrate the usefulness of the developed system. We have shown that both coatings can be clearly resolved and the thickness was determined to be 40 and 50 μm for the outer and inner coating layers, respectively. It was also found that the outer coating layer is relatively uniform, whereas the inner coating layer has many particle-like features. X-ray computed microtomography measurements carried out on the same pellet sample confirmed all these findings. The presented FF-OCT approach is inexpensive and has better spatial resolution compared with other non-destructive analysis techniques such as terahertz pulsed imaging, and is thus considered advantageous for the quantitative analysis of thin coatings on small pellet samples.
© 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

Entities:  

Keywords:  coating; excipients; image analysis; imaging methods; light-scattering; optical coherency tomography (OCT); pellet

Mesh:

Substances:

Year:  2013        PMID: 24186321     DOI: 10.1002/jps.23764

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  5 in total

1.  Low-cost hand-held probe for depth-resolved low-coherence interferometry.

Authors:  Paritosh Pande; Ryan L Shelton; Guillermo L Monroy; Ryan M Nolan; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2016-12-19       Impact factor: 3.732

2.  In situ process monitoring in selective laser sintering using optical coherence tomography.

Authors:  Michael R Gardner; Adam Lewis; Jongwan Park; Austin B McElroy; Arnold D Estrada; Scott Fish; Joseph J Beaman; Thomas E Milner
Journal:  Opt Eng       Date:  2018-03-01

3.  Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging.

Authors:  Paritosh Pande; Guillermo L Monroy; Ryan M Nolan; Ryan L Shelton; Stephen A Boppart
Journal:  J Sens       Date:  2016       Impact factor: 2.137

4.  Assessment of Mini-Tablets Coating Uniformity as a Function of Fluid Bed Coater Inlet Conditions.

Authors:  Magdalena Turk; Rok Šibanc; Rok Dreu; Maja Frankiewicz; Małgorzata Sznitowska
Journal:  Pharmaceutics       Date:  2021-05-18       Impact factor: 6.321

5.  Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation.

Authors:  Hungyen Lin; Yue Dong; Yaochun Shen; J Axel Zeitler
Journal:  J Pharm Sci       Date:  2015-06-17       Impact factor: 3.534