High-sensitivity troponin as a predictor of cardiac events and mortality in the stable dialysis population.

Hicham Cheikh Hassan1, Kenneth Howlin, Andrew Jefferys, Stephen T Spicer, Ananthakrishnapuram N Aravindan, Govindarajan Suryanarayanan, Bruce M Hall, Bruce D Cleland, Jeffrey K Wong, Michael G Suranyi, Angela Makris.   

Abstract

BACKGROUND: High-sensitivity cardiac troponin T (hs-cTnT) is a biomarker used in diagnosing myocardial injury. The clinical utility and the variation of this biomarker over time remain unclear in hemodialysis (HD) and peritoneal dialysis (PD) patients. We sought to determine whether hs-cTnT concentrations were predictive of myocardial infarction (MI) and death and to examine hs-cTnT variability over a 1-year period.
METHODS: A total of 393 nonacute HD and PD patients (70% HD and 30% PD) were followed in a prospective observational study for new MI and death.
RESULTS: Median hs-cTnT was 57 ng/L (interquartile range, 36-101 ng/L) with no observed difference between HD and PD patients (P = 0.11). Incremental increases in mortality (P = 0.024) and MI (P = 0.001) were observed with increasing hs-cTnT quartiles. MI incidence increased significantly across quartiles in both HD and PD patients (P = 0.012 and P = 0.025, respectively), whereas mortality increased only in HD patients (P = 0.015). For every increase of 25 ng/L in hs-cTnT, the unadjusted hazard ratio (HR) was 1.10 for mortality in the whole group (95% CI, 1.04-1.16, P = 0.001) and 1.16 for MI (95% CI, 1.08-1.23, P < 0.001). Adjusted HR for mortality was 1.07 (95% CI, 1.01-1.15, P = 0.04) and 1.14 for MI (95% CI, 1.06-1.22, P < 0.001). Changes in hs-cTnT from baseline concentrations after 1 year were minimal (55 ng/L vs 53 ng/L, P = 0.22) even in patients who had an MI (P = 0.53).
CONCLUSIONS: hs-cTnT appears to have a useful role in predicting MI and death in the dialysis population. Over a 1-year period concentrations remained stable even in patients who sustained a new cardiac event.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24185551     DOI: 10.1373/clinchem.2013.207142

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  13 in total

1.  B-Type Natriuretic Peptide and Cardiac Troponin I Are Associated With Adverse Outcomes in Stable Kidney Transplant Recipients.

Authors:  Petr Jarolim; Brian L Claggett; Michael J Conrad; Myra A Carpenter; Anastasia Ivanova; Andrew G Bostom; John W Kusek; Lawrence G Hunsicker; Paul F Jacques; Lisa Gravens-Mueller; Peter Finn; Scott D Solomon; Daniel E Weiner; Andrew S Levey; Marc A Pfeffer
Journal:  Transplantation       Date:  2017-01       Impact factor: 4.939

2.  Dry weight assessment by combined ultrasound and bioimpedance monitoring in low cardiovascular risk hemodialysis patients: a randomized controlled trial.

Authors:  Dimitrie Siriopol; Mihai Onofriescu; Luminita Voroneanu; Mugurel Apetrii; Ionut Nistor; Simona Hogas; Mehmet Kanbay; Radu Sascau; Dragos Scripcariu; Adrian Covic
Journal:  Int Urol Nephrol       Date:  2016-12-07       Impact factor: 2.370

3.  Prognostic value of high-sensitive cardiac troponin I in asymptomatic chronic hemodialysis patients.

Authors:  Barbara Maresca; Andrea Manzione; Alessandra Moioli; Gerardo Salerno; Patrizia Cardelli; Giorgio Punzo; Simona Barberi; Paolo Menè
Journal:  J Nephrol       Date:  2019-04-24       Impact factor: 3.902

Review 4.  Revascularization Strategies in Patients with Chronic Kidney Disease and Acute Coronary Syndromes.

Authors:  Evan C Klein; Ridhima Kapoor; David Lewandowski; Peter J Mason
Journal:  Curr Cardiol Rep       Date:  2019-08-30       Impact factor: 2.931

5.  Plasma biomarkers outperform echocardiographic measurements for cardiovascular risk prediction in kidney transplant recipients: results of the HOME ALONE study.

Authors:  Insa E Emrich; Anja L Scheuer; Kyrill S Rogacev; Felix Mahfoud; Stefan Wagenpfeil; Danilo Fliser; Stephan H Schirmer; Michael Böhm; Gunnar H Heine
Journal:  Clin Kidney J       Date:  2021-10-28

6.  High-sensitive troponin T increase after hemodialysis is associated with left ventricular global longitudinal strain and ultrafiltration rate.

Authors:  Serkan Ünlü; Asife Şahinarslan; Burak Sezenöz; Orhan Mecit Uludağ; Gökhan Gökalp; Özden Seçkin; Selim Turgay Arınsoy; Özlem Gülbahar; Nuri Bülent Boyacı
Journal:  Cardiol J       Date:  2018-10-19       Impact factor: 2.737

7.  High-sensitivity troponins in dialysis patients: variation and prognostic value.

Authors:  Sunna Snaedal; Peter Bárány; Sigrún H Lund; Abdul R Qureshi; Olof Heimbürger; Peter Stenvinkel; Christian Löwbeer; Karolina Szummer
Journal:  Clin Kidney J       Date:  2020-12-12

8.  High-Sensitivity Cardiac Troponin Concentrations in Patients with Chest Discomfort: Is It the Heart or the Kidneys As Well?

Authors:  Eline P M Cardinaels; Sibel Altintas; Mathijs O Versteylen; Ivo A Joosen; Laurens-Jan C Jellema; Joachim E Wildberger; Marco Das; Harry J Crijns; Otto Bekers; Marja P van Dieijen-Visser; Bastiaan L Kietselaer; Alma M A Mingels
Journal:  PLoS One       Date:  2016-04-20       Impact factor: 3.240

9.  High-Sensitivity Troponin T and C-Reactive Protein Have Different Prognostic Values in Hemo- and Peritoneal Dialysis Populations: A Cohort Study.

Authors:  Titi Chen; Hicham C Hassan; Pierre Qian; Monica Vu; Angela Makris
Journal:  J Am Heart Assoc       Date:  2018-02-24       Impact factor: 5.501

10.  Peritoneal dialysis in Sichuan province of China - report from the Chinese National Renal Data System.

Authors:  Changwei Wu; Xiuling Chen; Amanda Ying Wang; Jin Chen; Hui Gao; Guisen Li; Li Wang; Daqing Hong
Journal:  Ren Fail       Date:  2018-11       Impact factor: 2.606

View more