Literature DB >> 24183196

Effect of warmed irrigation solution on core body temperature during hip arthroscopy for femoroacetabular impingement.

Dante Parodi1, Juanjosé Valderrama2, Carlos Tobar2, Javier Besomi2, Jaime López2, Joaquín Lara2, Juan Pablo Ilic2.   

Abstract

PURPOSE: To determine the effect of warming arthroscopic irrigation solution on core body temperature during hip arthroscopic surgery in patients with femoroacetabular impingement.
METHODS: An analytical, prospective, observational study was performed in a cohort of 166 consecutive patients. All patients underwent hip arthroscopy for treatment of femoroacetabular impingement. Two groups were studied: patients operated on with arthroscopic irrigation solution warmed up to 32°C ± 2°C (89.6°F ± 3.6°F) and a control group comprising patients operated on with irrigation solution used at room temperature. Relevant information was collected regarding the patients (age, sex, body mass index, and blood pressure) and the procedure (volume and temperature of saline solution, pressure of fluid pump, surgery time, and room temperature). Corresponding statistical analysis was performed with STATA 11.0 (StataCorp, College Station, TX), by use of descriptive statistics, parametric and nonparametric tests, and a generalized estimating equation model for repeated measurements.
RESULTS: Both groups were comparable in terms of age, sex, systolic and diastolic blood pressure, body mass index, volume of irrigation solution used, and room temperature. The mean age of the cohort was 33 years (range, 14 to 60 years); mean body mass index, 23.7 kg/m(2) (range, 17.2 to 34 kg/m(2)); mean volume of irrigation solution, 26 L (range, 12 to 39 L); mean systolic blood pressure, 97 mm Hg; mean diastolic blood pressure, 51 mm Hg; and mean surgical time, 110 minutes. A decrease in core body temperature by 0.5°C (0.9°F) or greater occurred during the course of surgery in 66% of patients in the control group versus 28% in the warmed-solution group (P < .001). At least 1 core body temperature measurement of less than 36°C (96.8°F) was recorded in 48% of patients in the control group versus 14% in the warmed-solution group (P < .001). The trend toward a decrease in core body temperature was 4 times greater in the control group than in the warmed-solution group (P < .001).
CONCLUSIONS: Use of arthroscopic irrigation solution warmed up to 32°C (89.6°F) reduces the risk of a decrease in core body temperature during hip arthroscopy in patients with femoroacetabular impingement. LEVEL OF EVIDENCE: Level II, analytical, prospective, comparative study in a cohort of consecutive patients.
Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24183196     DOI: 10.1016/j.arthro.2013.08.035

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  6 in total

1.  Basic Hip Arthroscopy: Supine Patient Positioning and Dynamic Fluoroscopic Evaluation.

Authors:  Sandeep Mannava; Elizabeth A Howse; Austin V Stone; Allston J Stubbs
Journal:  Arthrosc Tech       Date:  2015-08-24

Review 2.  Hip arthroscopy complications regarding surgery and early postoperative care: retrospective study and review of literature.

Authors:  R Seijas; O Ares; A Sallent; X Cuscó; P Álvarez-Díaz; R Tejedor; R Cugat
Journal:  Musculoskelet Surg       Date:  2016-12-07

3.  Procedure length is independently associated with overnight hospital stay and 30-day readmission following anterior cruciate ligament reconstruction.

Authors:  Venkat Boddapati; Michael C Fu; Benedict U Nwachukwu; Christopher L Camp; Andrea M Spiker; Riley J Williams; Anil S Ranawat
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-07-24       Impact factor: 4.342

Review 4.  The influence of the irrigating solution on articular cartilage in arthroscopic surgery: A systematic review.

Authors:  Vandit Sardana; Joanna Burzynski; Giles R Scuderi
Journal:  J Orthop       Date:  2019-02-28

5.  Heated wire humidification circuit attenuates the decrease of core temperature during general anesthesia in patients undergoing arthroscopic hip surgery.

Authors:  Sooyong Park; Seok-Hwa Yoon; Ann Misun Youn; Seung Hyun Song; Ja Gyung Hwang
Journal:  Korean J Anesthesiol       Date:  2017-06-14

6.  Metabolic and Hemodynamic Results and Early Complications in Simultaneous Bilateral versus Unilateral Hip Arthroscopy.

Authors:  Bernardo Aguilera-Bohórquez; Mauricio Pachón; Miguel Sánchez; Orlando Ramos-Cardozo; Erika Cantor
Journal:  Clin Orthop Surg       Date:  2019-11-12