Literature DB >> 24172266

Effects of sodium on measuring relative blood volume during hemodialysis differ by techniques.

Susanne Kron1, Reinhard Wenkel, Til Leimbach, Sabine Aign, Joachim Kron.   

Abstract

Recording the relative blood volume is a standard feature of modern dialysis devices, enabling feedback guidance of ultrafiltration and dialysate conductivity. Technically, the process is based on optical or ultrasonic methods. On the grounds of clinical evidence suggesting a malfunction of the optical hemoglobin (Hb)-dependent absorbance method in the presence of sodium changes, we compared the system with the ultrasonic method. Six patients underwent hemodialysis with a step sodium profile (140, 150, 130, and 140 mmol/L, hourly switch), with two dialysis devices featuring the optical and the ultrasonic blood volume detector, respectively. The ultrasonic system recorded a decreasing blood volume throughout the treatment. With the optical method, changes in dialysate sodium led to inverse deviations of the blood volume curve. In another treatment without profile administering, a bolus of hypertonic sodium led to the detection of a rapid 8.7% reduction in blood volume with the optical method, which was not observed with the ultrasonic device. Blood volume monitors using the optical absorbance device are influenced by osmotic changes. An increase in osmolality produces a paradox drop in the measured blood volume and vice versa rendering the monitor inappropriate for use in sodium profiling.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24172266     DOI: 10.1097/MAT.0b013e3182a4b45e

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Concordance of absolute and relative plasma volume changes and stability of Fcells in routine hemodialysis.

Authors:  Daniel Schneditz; Werner Ribitsch; Gernot Schilcher; Matthias Uhlmann; Yossi Chait; Vanessa Stadlbauer
Journal:  Hemodial Int       Date:  2015-08-05       Impact factor: 1.812

2.  Effect of plasma sodium concentration on blood pressure regulators during hemodialysis: a randomized crossover study.

Authors:  Esmée M Ettema; Johanna Kuipers; Martijn van Faassen; Henk Groen; Arie M van Roon; Joop D Lefrandt; Ralf Westerhuis; Ido P Kema; Harry van Goor; Ron T Gansevoort; Carlo A J M Gaillard; Casper F M Franssen
Journal:  BMC Nephrol       Date:  2018-08-22       Impact factor: 2.388

3.  Comparison of four different hematocrit assays and the effect of albumin on their measurements.

Authors:  Amelie Pare; Laura Kippen; Catherine Wagg; Matt Longmore; Soren Boysen
Journal:  Front Vet Sci       Date:  2022-08-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.