Literature DB >> 24169077

Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study.

Ian T Meredith1, Stephen G Worthley, Robert J Whitbourn, Paul Antonis, Joseph K Montarello, Andrew E Newcomb, Siohban Lockwood, Nicole Haratani, Dominic J Allocco, Keith D Dawkins.   

Abstract

AIMS: To assess outcomes with a new fully repositionable and retrievable valve for transcatheter aortic valve replacement (TAVR). METHODS AND
RESULTS: The Lotus Aortic Valve System is designed to facilitate precise positioning and minimise paravalvular regurgitation. REPRISE I enrolled symptomatic, high-surgical-risk patients with severe aortic stenosis. The primary endpoint (clinical procedural success) included successful implantation without major adverse cardiovascular or cerebrovascular events (MACCE). In all patients (N=11) the first Lotus Valve was successfully deployed. Partial resheathing to facilitate accurate placement was attempted and successfully performed in four patients; none required full retrieval. The primary endpoint was achieved in 9/11 with no in-hospital MACCE in 10/11. There was one major stroke; in another patient, discharge mean aortic gradient was 22 mmHg (above the primary endpoint threshold of 20 mmHg), but improved to 15 mmHg at 30 days. The cohort's mean aortic gradient decreased from 53.9±20.9 mmHg at baseline to 15.4±4.6 mmHg (p<0.001) at one year; valve area increased from 0.7±0.2 cm2 to 1.5±0.2 cm2 (p<0.001). Discharge paravalvular aortic regurgitation, adjudicated by an independent core laboratory, was mild (n=2), trivial (n=1), or absent (n=8). Four patients required a permanent pacemaker post-procedure. There were no deaths, myocardial infarctions or new strokes through one year.
CONCLUSIONS: Initial results support proof-of-concept with the Lotus Valve for TAVR.

Entities:  

Mesh:

Year:  2014        PMID: 24169077     DOI: 10.4244/EIJV9I11A216

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  22 in total

1.  Transcatheter Advances in the Treatment of Adult and Congenital Valvular Heart Disease.

Authors:  Jayendrakumar S Patel; Samir R Kapadia; Lourdes Prieto; E Murat Tuzcu; Amar Krishnaswamy
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-11

Review 2.  Pacemaker implantation after transcatheter aortic valve: why is this still happening?

Authors:  Stefan Toggweiler; Richard Kobza
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

3.  Mechanically expanding transcatheter aortic valves: pros and cons of a unique device technology.

Authors:  Kenan Yalta; Muhammet Gurdogan; Cafer Zorkun; Yekta Gurlertop
Journal:  Cardiovasc Diagn Ther       Date:  2018-08

4.  The Lotus dilemma-respond to paravalvular leakage, but not answering pacemaker implantations?

Authors:  Costanza Pellegrini; Christian Hengstenberg; Oliver Husser
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

5.  Transcatheter aortic valve implantation with the repositionable and fully retrievable Lotus Valve SystemTM.

Authors:  Rodrigo Bagur; Tawfiq Choudhury; Mamas A Mamas
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 6.  The Lotus Valve System: an In-depth Review of the Technology.

Authors:  Matthew E Seigerman; Ashwin Nathan; Saif Anwaruddin
Journal:  Curr Cardiol Rep       Date:  2019-11-25       Impact factor: 2.931

Review 7.  Advances in transcatheter valve therapies.

Authors:  Daniel H Steinberg; Mario Castillo-Sang; Eric R Powers
Journal:  J Cardiovasc Transl Res       Date:  2014-04-10       Impact factor: 4.132

Review 8.  Transcatheter Aortic Valve Replacement: Outcomes, Indications, Complications, and Innovations.

Authors:  Michael N Young; Ignacio Inglessis
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-09-22

9.  Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis.

Authors:  Susheel Kodali; Vinod H Thourani; Jonathon White; S Chris Malaisrie; Scott Lim; Kevin L Greason; Mathew Williams; Mayra Guerrero; Andrew C Eisenhauer; Samir Kapadia; Dean J Kereiakes; Howard C Herrmann; Vasilis Babaliaros; Wilson Y Szeto; Rebecca T Hahn; Philippe Pibarot; Neil J Weissman; Jonathon Leipsic; Philipp Blanke; Brian K Whisenant; Rakesh M Suri; Raj R Makkar; Girma M Ayele; Lars G Svensson; John G Webb; Michael J Mack; Craig R Smith; Martin B Leon
Journal:  Eur Heart J       Date:  2016-03-31       Impact factor: 29.983

Review 10.  Advances in Transcatheter Aortic Valve Replacement.

Authors:  Neal S Kleiman; Michael J Reardon
Journal:  Methodist Debakey Cardiovasc J       Date:  2016 Jan-Mar
View more