Percutaneous axillary vein approach in pediatric pacing: comparison with subclavian vein approach.

Massimo Stefano Silvetti1, Silvia Placidi, Rosalinda Palmieri, Daniela Righi, Lucilla Ravà, Fabrizio Drago.   

Abstract

AIMS: The subclavian vein approach has been used for 20 years in our center for pacemaker (PM) implantation in children, but it carries risks of hemothorax/pneumothorax and lead fracture, which could be reduced by axillary vein approach. METHODS AND
RESULTS: This is a prospective study enrolling the first 48 consecutive pediatric patients (age: 12.3 ± 4.6 years) who underwent PM/implantable cardioverter-defibrillator leads implantation through axillary vein (guided by contrast venography) between 2009 and 2012 (group I). A comparison was made with the outcomes of the subclavian vein approach (group II) in 41 patients, age 12.3 ± 4.8 years, consecutively enrolled between 2006 and 2011. The two groups showed no significant differences for the variables examined except for follow-up, longer in group II, and for alternative ventricular pacing sites, more frequent in group I. Axillary vein diameter was 7.9 ± 1.7 mm and showed positive correlation with height (r = 0.77). The axillary vein approach was effective in 93.7% of patients. The unsuccessful procedures occurred in patients with significantly lower age and smaller venous diameters. The subclavian vein approach was effective in 100% of patients. Sixty-two leads were implanted in group I, 54 in group II. There were neither intraoperative complications in both the groups, nor significant differences for early and late complications.
CONCLUSIONS: The axillary vein approach for PM implantation in children is effective and safe for physicians skilled with subclavian vein approach. Younger patients with smaller vein diameters are at low risk for unsuccessful procedure. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  cardiac pacing; children; congenital heart defect; pacing complication; transvenous pacing

Mesh:

Year:  2013        PMID: 24164685     DOI: 10.1111/pace.12283

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.

Authors:  Federico Migliore; Mariachiara Siciliano; Manuel De Lazzari; Sonia Ferretto; Chiara Dalla Valle; Alessandro Zorzi; Domenico Corrado; Sabino Iliceto; Emanuele Bertaglia
Journal:  J Interv Card Electrophysiol       Date:  2015-05-09       Impact factor: 1.900

2.  Tailoring of arteriovenous graft-to-vein anastomosis angle to attenuate pathological flow fields.

Authors:  Dillon Williams; Eric C Leuthardt; Guy M Genin; Mohamed Zayed
Journal:  Sci Rep       Date:  2021-06-09       Impact factor: 4.996

3.  Optimized Axillary Vein Technique versus Subclavian Vein Technique in Cardiovascular Implantable Electronic Device Implantation: A Randomized Controlled Study.

Authors:  Peng Liu; Yi-Feng Zhou; Peng Yang; Yan-Sha Gao; Gui-Ru Zhao; Shi-Yan Ren; Xian-Lun Li
Journal:  Chin Med J (Engl)       Date:  2016-11-20       Impact factor: 2.628