Literature DB >> 24163987

Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder.

Khanittha Lairakdomrong1, Suphot Srimahachota, Pornthep Lertsapcharoen, Jarkarpun Chaipromprasit, Smonporn Boonyaratavej, Patcharin Kaewsukkho.   

Abstract

BACKGROUND: Atrial septal defect (ASD) is a common congenital heart disease in adults. Amplatzer septal occluder is one of the most common devices used for transcatheter closure due to its high success rate and ease to implant. Cocoon atrial septal occluder is a new nitinol-based device, its shape resembles Amplatzer septal occluder but coated with platinum to prevent nickel release. Little is known about clinical outcomes of large ASD closure using Cocoon atrial septal occluder
OBJECTIVE: To review our experience in closure of secundum ASD in adults by Cocoon septal occluder and to compare the clinical outcomes and results of the patients who had ASD closure with a device greater than or equal to 30 mm and less than 30 mm. MATERIAL AND
METHOD: Between November 2005 and October 2008, 63 consecutive patients underwent transesophageal echocardiography (TEE)--guided transcatheter closure of secundum ASD. The patients were divided into two groups (Groups' 1 and 2) according to device diameter that is greater than or equal to 30 mm (n = 31) and less than 30 mm (n = 32), respectively. Clinical outcomes, complications, and transthoracic echocardiography (TTE) before hospital discharge, one to three months, and one-year were analyzed.
RESULTS: Device implantations were successful in 27 patients (87.1%) in group 1 and 31 patients (96.9%) in group 2 (p = 0.196). The maximum size of secundum ASD in group 1 determined by TTE, TEE, and balloon sizing diameter (BSD) were 22.6 +/- 5.0 mm (range 15-32), 28.1 +/- 4.8 mm (range 19-39), and 31 +/- 3.5 mm (range 23-38) respectively. The maximum size of secundum ASD in group 2 determined by TTE, TEE, and BSD were 19.7 +/- 4.4 mm (range 12-31), 20.4 +/- 3.4 mm (range 13-26), and 23.1 +/- 2.9 mm (range 15-30) respectively. The mean device size in groups 1 and 2 were 33.5 +/- 3.1 mm and 24.6 +/- 3.3 mm, respectively. Four patients (12.9%) in group 1 had unsuccessful implantations. All of them were in the first 15 cases of using large device and two of them had device embolization requiring surgical removal. One patient (3.1%) in group 2 had an unsuccessful implantation and had device embolization requiring surgical removal. The patients in both groups gradually improved in clinical symptoms with decreased RVsystolic pressure and decreased RV size with complete ASD closure at one year
CONCLUSION: Transcatheter closure of large secundum ASD by Cocoon septal occluder is feasible with hemodynamic benefit. However complication rates are higher with large ASD closure with device size greater than or equal to 30 mm especially during the early "learning curve" period. With experience, the complication rate declines and the success rate is no different from the group with smaller device size.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24163987

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  5 in total

1.  Initial Experience with the Nit-Occlud ASD-R: Short-Term Results.

Authors:  Mustafa Orhan Bulut; Ilker Kemal Yucel; Mehmet Kucuk; Sevket Balli; Evic Zeynep Basar; Ahmet Celebi
Journal:  Pediatr Cardiol       Date:  2016-06-09       Impact factor: 1.655

2.  Comparison of Transcatheter Atrial Septal Defect Closure in Children, Adolescents and adults: Differences, Challenges and Short-, Mid- and Long-Term Results.

Authors:  Turkay Saritas; Ilker Kemal Yucel; Ibrahim Halil Demir; Fadli Demir; Abdullah Erdem; Ahmet Celebi
Journal:  Korean Circ J       Date:  2016-10-20       Impact factor: 3.243

3.  Cocoon devices for transcatheter closure of atrial septal defect and patent ductus arteriosus in children: Single center experience.

Authors:  Hyam Mahmoud; Alin Nicolescu; Cristina Filip; Gabriela Duica; Georgiana Nicolae; Eliza Elena Cinteza
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.817

4.  Transcatheter closure of secundum atrial septal defect using Cocoon septal occluder: immediate and long-term results.

Authors:  Santosh Kumar Sinha; Mahmodullah M Razi; Najeeb Ullah Sofi; Manoj Kumar Rohit; Umeshwar Pandey; Awadhesh Kumar Sharma; Mohit Sachan; Puneet Aggarwal; Mukesh Jha; Praveen Shukla; Ramesh Thakur; Vinay Krishna; Rakesh Kumar Verma
Journal:  Egypt Heart J       Date:  2022-08-13

5.  Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44-48 mm), a single Chinese cardiac center experience.

Authors:  Qiang Chen; Hua Cao; Gui-Can Zhang; Liang-Wan Chen; Fan Xu; Jia-Xin Zhang
Journal:  J Cardiothorac Surg       Date:  2017-09-02       Impact factor: 1.637

  5 in total