Literature DB >> 24158470

Attenuation of systolic blood pressure and pulse transit time hysteresis during exercise and recovery in cardiovascular patients.

Qing Liu, Bryan P Yan, Cheuk-Man Yu, Yuan-Ting Zhang, Carmen C Y Poon.   

Abstract

Pulse transit time (PTT) is a cardiovascular parameter of emerging interest due to its potential to estimate blood pressure (BP) continuously and without a cuff. Both linear and nonlinear equations have been used in the estimation of BP based on PTT. This study, however, demonstrates that there is a hysteresis phenomenon between BP and PTT during and after dynamic exercise. A total of 46 subjects including 16 healthy subjects, 13 subjects with one or more cardiovascular risk factors, and 17 patients with cardiovascular disease underwent graded exercise stress test. PTT was measured from electrocardiogram and photoplethysmogram of the left index finger of the subject, i.e., a pathway that includes predominately aorta, brachial, and radial arteries. The results of this study showed that, for the same systolic BP (SBP), PTT measured during exercise was significantly larger than PTT measured during recovery for all subject groups. This hysteresis was further quantified as both normalized area bounded by the SBP-PTT relationship (AreaN) and SBP difference at PTT during peak exercise plus 20 ms (ΔSBP20). Significant attenuation of both AreaN (p <; 0.05) and ΔSBP20 (p <; 0.01) is observed in cardiovascular patients compared with healthy subjects, independent of resting BP. Since the SBP-PTT relationship are determined by the mechanical properties of arterial wall, which is predominately mediated by the sympathetic nervous system through altered vascular smooth muscle (VSM) tone during exercise, results of this study are consistent with the previous findings of autonomic nervous dysfunction in cardiovascular patients. We further conclude that VSM tone has a nonnegligible influence on the BP-PTT relationship and thus should be considered in the PTT-based BP estimation.

Entities:  

Mesh:

Year:  2014        PMID: 24158470     DOI: 10.1109/TBME.2013.2286998

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  15 in total

Review 1.  Cuffless Blood Pressure Monitoring: Academic Insights and Perspectives Analysis.

Authors:  Shiyun Li; Can Zhang; Zhirui Xu; Lihua Liang; Ye Tian; Long Li; Huaping Wu; Sheng Zhong
Journal:  Micromachines (Basel)       Date:  2022-07-30       Impact factor: 3.523

2.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Authors:  Yali Zheng; Carmen C Y Poon; Bryan P Yan; James Y W Lau
Journal:  J Med Syst       Date:  2016-07-22       Impact factor: 4.460

3.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

4.  Toward a Smartphone Application for Estimation of Pulse Transit Time.

Authors:  He Liu; Kamen Ivanov; Yadong Wang; Lei Wang
Journal:  Sensors (Basel)       Date:  2015-10-27       Impact factor: 3.576

5.  An Experimental Study of the Effects of External Physiological Parameters on the Photoplethysmography Signals in the Context of Local Blood Pressure (Hydrostatic Pressure Changes).

Authors:  Hongwei Yuan; Sven Poeggel; Thomas Newe; Elfed Lewis; Charusluk Viphavakit; Gabriel Leen
Journal:  Sensors (Basel)       Date:  2017-03-10       Impact factor: 3.576

6.  Vascular smooth muscle cell contraction and relaxation in the isolated aorta: a critical regulator of large artery compliance.

Authors:  Arthur J A Leloup; Cor E Van Hove; Sofie De Moudt; Guido R Y De Meyer; Gilles W De Keulenaer; Paul Fransen
Journal:  Physiol Rep       Date:  2019-02

Review 7.  Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices.

Authors:  Jaegeol Cho
Journal:  J Healthc Eng       Date:  2019-06-16       Impact factor: 2.682

8.  Data to diagnosis in global health: a 3P approach.

Authors:  Rahul Krishnan Pathinarupothi; P Durga; Ekanath Srihari Rangan
Journal:  BMC Med Inform Decis Mak       Date:  2018-09-04       Impact factor: 2.796

9.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

Review 10.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.