Literature DB >> 24156253

Intrapartum fetal heart rate monitoring: evaluation of a standardized system of interpretation for prediction of metabolic acidosis at delivery and neonatal neurological morbidity.

Emanuele Soncini1, Simone Paganelli, Cristina Vezzani, Giancarlo Gargano, La Sala Giovanni Battista.   

Abstract

OBJECTIVE: To assess the ability of the intrapartum fetal heart rate interpretation system developed in 2008 by the National Institute of Child Health and Human Development (NICHD) to predict fetal metabolic acidosis at delivery and neonatal neurological morbidity.
METHODS: We analyzed the intrapartum fetal heart rate tracings of 314 singleton fetuses at ≥ 37 weeks using the NICHD three-tier system of interpretation: Category I (normal), Category II (indeterminate) and Category III (abnormal). Category II was further divided into Category IIA, with moderate fetal heart rate variability or accelerations, and Category IIB, with minimal/absent fetal heart rate variability and no accelerations. The presence and duration of the different patterns were compared with several clinical neonatal outcomes and with umbilical artery acid-base balance at birth.
RESULTS: The mean values of pH and base excess decreased proportionally as tracings worsened (p < 0.001). The duration of at least 30 min for Category III tracings was highly predictive of a pH <7.00 and a base excess ≤-12 mmol/L. The same was true for the duration of Category IIB tracings that lasted for at least 50 min.
CONCLUSIONS: Our study demonstrates that the interpretation of fetal heart rate tracings based on a strictly standardized system is closely associated with umbilical artery acid-base status at delivery.

Entities:  

Keywords:  Acidosis; brain; cardiotocography; fetal diseases; hypoxia-ischemia; labor; obstetric

Mesh:

Year:  2013        PMID: 24156253     DOI: 10.3109/14767058.2013.858690

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  2 in total

1.  Parasympathetic tone variations according to umbilical cord pH at birth: a computerized fetal heart rate variability analysis.

Authors:  Laura Butruille; Julien De Jonckheere; Mathilde Flocteil; Charles Garabedian; Véronique Houfflin-Debarge; Laurent Storme; Philippe Deruelle; Régis Logier
Journal:  J Clin Monit Comput       Date:  2016-11-15       Impact factor: 2.502

2.  Model for Early Prediction of Preeclampsia: A Nested Case Controlled Study in Indian Women.

Authors:  Sonali Yadav; Sukhanshi Khandpur; Yogendra Singh Yadav; Madhu Mati Goel; Urmila Singh; Shankar Madhav Natu; Mahendra Pal S Negi; Lokendra Kumar Sharma; Swasti Tiwari
Journal:  J Obstet Gynaecol India       Date:  2021-06-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.