Literature DB >> 24149747

Accuracy and reliability of GPS devices for measurement of sports-specific movement patterns related to cricket, tennis, and field-based team sports.

William M Vickery1, Ben J Dascombe, John D Baker, Dean G Higham, Wayne A Spratford, Rob Duffield.   

Abstract

The aim of this study was to determine the accuracy and reliability of 5, 10, and 15 Hz global positioning system (GPS) devices. Two male subjects (mean ± SD; age, 25.5 ± 0.7 years; height, 1.75 ± 0.01 m; body mass, 74 ± 5.7 kg) completed 10 repetitions of drills replicating movements typical of tennis, cricket, and field-based (football) sports. All movements were completed wearing two 5 and 10 Hz MinimaxX and 2 GPS-Sports 15 Hz GPS devices in a specially designed harness. Criterion movement data for distance and speed were provided from a 22-camera VICON system sampling at 100 Hz. Accuracy was determined using 1-way analysis of variance with Tukey's post hoc tests. Interunit reliability was determined using intraclass correlation (ICC), and typical error was estimated as coefficient of variation (CV). Overall, for the majority of distance and speed measures, as measured using the 5, 10, and 15 Hz GPS devices, were not significantly different (p > 0.05) to the VICON data. Additionally, no improvements in the accuracy or reliability of GPS devices were observed with an increase in the sampling rate. However, the CV for the 5 and 15 Hz devices for distance and speed measures ranged between 3 and 33%, with increasing variability evident in higher speed zones. The majority of ICC measures possessed a low level of interunit reliability (r = -0.35 to 0.39). Based on these results, practitioners of these devices should be aware that measurements of distance and speed may be consistently underestimated, regardless of the movements performed.

Entities:  

Mesh:

Year:  2014        PMID: 24149747     DOI: 10.1519/JSC.0000000000000285

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  22 in total

Review 1.  Sprint Running Performance Monitoring: Methodological and Practical Considerations.

Authors:  Thomas Haugen; Martin Buchheit
Journal:  Sports Med       Date:  2016-05       Impact factor: 11.136

2.  The Validity and Reliability of Wearable Microtechnology for Intermittent Team Sports: A Systematic Review.

Authors:  Zachary L Crang; Grant Duthie; Michael H Cole; Jonathon Weakley; Adam Hewitt; Rich D Johnston
Journal:  Sports Med       Date:  2020-12-24       Impact factor: 11.136

3.  Accuracy Assessment of a GPS Device for Maximum Sprint Speed.

Authors:  Kathryn L Alphin; Olivia M Sisson; Brynn L Hudgins; Catherine D Noonan; Jennifer A Bunn
Journal:  Int J Exerc Sci       Date:  2020-02-01

4.  The design of the run Clever randomized trial: running volume, -intensity and running-related injuries.

Authors:  Daniel Ramskov; Rasmus Oestergaard Nielsen; Henrik Sørensen; Erik Parner; Martin Lind; Sten Rasmussen
Journal:  BMC Musculoskelet Disord       Date:  2016-04-23       Impact factor: 2.362

5.  Accuracy of a 10 Hz GPS Unit in Measuring Shuttle Velocity Performed at Different Speeds and Distances (5 - 20 M).

Authors:  Marco Beato; Davide Bartolini; Gianluigi Ghia; Paola Zamparo
Journal:  J Hum Kinet       Date:  2016-12-15       Impact factor: 2.193

6.  Physiological responses and match characteristics in professional tennis players during a one-hour simulated tennis match.

Authors:  Bülent Kilit; Ömer Şenel; Erşan Arslan; Sema Can
Journal:  J Hum Kinet       Date:  2016-07-02       Impact factor: 2.193

7.  Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports.

Authors:  Matthias W Hoppe; Christian Baumgart; Ted Polglaze; Jürgen Freiwald
Journal:  PLoS One       Date:  2018-02-08       Impact factor: 3.240

8.  The Activity Profile of Young Tennis Athletes Playing on Clay and Hard Courts: Preliminary Data.

Authors:  Lucas Adriano Pereira; Victor Freitas; Felipe Arruda Moura; Marcelo Saldanha Aoki; Irineu Loturco; Fábio Yuzo Nakamura
Journal:  J Hum Kinet       Date:  2016-04-13       Impact factor: 2.193

9.  Player Monitoring in Indoor Team Sports: Concurrent Validity of Inertial Measurement Units to Quantify Average and Peak Acceleration Values.

Authors:  Mareike Roell; Kai Roecker; Dominic Gehring; Hubert Mahler; Albert Gollhofer
Journal:  Front Physiol       Date:  2018-02-27       Impact factor: 4.566

10.  Validity and Reliability of 10-Hz Global Positioning System to Assess In-line Movement and Change of Direction.

Authors:  Pantelis T Nikolaidis; Filipe M Clemente; Cornelis M I van der Linden; Thomas Rosemann; Beat Knechtle
Journal:  Front Physiol       Date:  2018-03-15       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.