Literature DB >> 24149310

Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

Victor M Reis1, Roland Van den Tillaar, Mario C Marques.   

Abstract

The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x < 5% at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity associated with the 4 mmol·L(-1) threshold.The results of the present study show that, in highly trained runners, it is possible to use heart rate as an accurate index of the external work rate during sub maximal running speeds.

Entities:  

Keywords:  Running velocity; internal load; relationships; standard error

Year:  2011        PMID: 24149310      PMCID: PMC3737894     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  19 in total

1.  Validity of the heart rate deflection point as a predictor of lactate threshold during running.

Authors:  J A Vachon; D R Bassett; S Clarke
Journal:  J Appl Physiol (1985)       Date:  1999-07

2.  Estimating relative physical workload using heart rate monitoring: a validation by whole-body indirect calorimetry.

Authors:  Martin Garet; Gil Boudet; Christophe Montaurier; Michel Vermorel; Jean Coudert; Alain Chamoux
Journal:  Eur J Appl Physiol       Date:  2004-12-18       Impact factor: 3.078

3.  Estimation of oxygen uptake during fast running using accelerometry and heart rate.

Authors:  Barry W Fudge; John Wilson; Chris Easton; Laura Irwin; Jonathan Clark; Olivia Haddow; Bengt Kayser; Yannis P Pitsiladis
Journal:  Med Sci Sports Exerc       Date:  2007-01       Impact factor: 5.411

Review 4.  Heart rate measurements as an index of energy expenditure and energy balance in ruminants: a review.

Authors:  A Brosh
Journal:  J Anim Sci       Date:  2007-01-15       Impact factor: 3.159

5.  Longitudinal Study in 3,000 m Male Runners: Relationship between Performance and Selected Physiological Parameters.

Authors:  José A Bragada; Paulo J Santos; José A Maia; Paulo J Colaço; Vítor P Lopes; Tiago M Barbosa
Journal:  J Sports Sci Med       Date:  2010-09-01       Impact factor: 2.988

6.  Inclusion of Exercise Intensities Above the Lactate Threshold in VO2/Running Speed Regression Does not Improve the Precision of Accumulated Oxygen Deficit Estimation in Endurance-Trained Runners.

Authors:  Victor M Reis; António J Silva; António Ascensão; José A Duarte
Journal:  J Sports Sci Med       Date:  2005-12-01       Impact factor: 2.988

7.  Accelerometer output and MET values of common physical activities.

Authors:  Sarah L Kozey; Kate Lyden; Cheryl A Howe; John W Staudenmayer; Patty S Freedson
Journal:  Med Sci Sports Exerc       Date:  2010-09       Impact factor: 5.411

8.  Unreliability of the %VO2 reserve versus %heart rate reserve relationship for aerobic effort relative intensity assessment in chronic heart failure patients on or off beta-blocking therapy.

Authors:  Alessandro Mezzani; Ugo Corrà; Andrea Giordano; Michele Cafagna; Edvige Palazzo Adriano; Pantaleo Giannuzzi
Journal:  Eur J Cardiovasc Prev Rehabil       Date:  2007-02

9.  Non-linear relationships between central cardiovascular variables and VO2 during incremental cycling exercise in endurance-trained individuals.

Authors:  C A Vella; R A Robergs
Journal:  J Sports Med Phys Fitness       Date:  2005-12       Impact factor: 1.637

10.  Acceleration versus heart rate for estimating energy expenditure and speed during locomotion in animals: tests with an easy model species, Homo sapiens.

Authors:  Lewis G Halsey; Emily L C Shepard; Carl J Hulston; Michelle C Venables; Craig R White; Asker E Jeukendrup; Rory P Wilson
Journal:  Zoology (Jena)       Date:  2008-03-28       Impact factor: 2.240

View more
  3 in total

Review 1.  Practical physical activity measurement in youth: a review of contemporary approaches.

Authors:  Jerome N Rachele; Steven M McPhail; Tracy L Washington; Thomas F Cuddihy
Journal:  World J Pediatr       Date:  2012-08-12       Impact factor: 2.764

2.  Estimating Heart Rate, Energy Expenditure, and Physical Performance With a Wrist Photoplethysmographic Device During Running.

Authors:  Jakub Parak; Maria Uuskoski; Jan Machek; Ilkka Korhonen
Journal:  JMIR Mhealth Uhealth       Date:  2017-07-25       Impact factor: 4.773

3.  Physiological responses and exercise preference between the Trikke and the bicycle ergometer.

Authors:  Eddie T C Lam; Kenneth Sparks; Michele A Barton-Verdi; Allison Lowe; Davon Jones; Edmond C Lam
Journal:  J Exerc Sci Fit       Date:  2016-04-23       Impact factor: 3.103

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.