Literature DB >> 24147261

Collecting a comprehensive evidence base to monitor fracture rehabilitation: A case study.

Stuart A Callary1, Dominic Thewlis, Alex V Rowlands, David M Findlay, Lucian B Solomon.   

Abstract

AIM: To determine the feasibility and potential role of combining radiostereometric analysis (RSA), gait analysis and activity monitoring in the follow-up of fracture patients.
METHODS: Two patients with similar 41B3 tibial plateau fractures were treated by open reduction internal fixation augmented with impaction bone grafting and were instructed to partial weight bear to 10 kg for the first six postoperative weeks. Fracture reduction and fixation were assessed by postoperative computer tomographic (CT) scanning. Both patients had tantalum markers inserted intra-operatively to monitor their fracture stability during healing using RSA and differentially loaded RSA (DLRSA) at 6 and 12 wk postoperatively. Gait analyses were performed at 1, 2, 6, and 12 wk postoperatively. Activity monitors were worn for 4 wk between the 2 and 6 wk appointments. In addition to gait analysis, knee function was assessed using the patient reported Lysholm scores, and doctor reported knee range of motion and stability, at 6 and 12 wk postoperatively.
RESULTS: There were no complications. CT demonstrated that both fractures were reduced anatomically. Gait analysis indicated that Patient 1 bore weight to 60% of body weight at 2 wk postoperative and 100% at 6 wk. Patient 2 bore weight at 10% of body weight to 6 wk and had very low joint contact forces to that time. At 12 wk however, there was no difference between the gait patterns in the two patients. Patient 1 increased activities of moderate-vigorous intensity from 20 to 60 min/d between 2 and 6 postoperative weeks, whereas Patient 2 remained more stable at 20-30 min/d. The Lysholm scores were similar for both patients and did not improve between 6 and 12 wk postoperatively. DLRSA examination at 12 wk showed that both patients were comfortable to weight bear to 80 kg and under this weight the fractures displaced less than 0.4 mm. RSA measurements demonstrated over time fracture migrations of less than 2 mm in both cases. However, Patient 2, who followed the postoperative weight bearing instructions most closely, displaced less (0.3 mm vs 1.6 mm).
CONCLUSION: This study demonstrates the potential of using a combination of RSA, gait analysis and activity monitoring to obtain a comprehensive evidence base for postoperative weight bearing schedules during fracture healing.

Entities:  

Keywords:  Activity monitoring; Gait analysis; Lower limb trauma; Radiostereometric analysis; Rehabilitation protocols

Year:  2013        PMID: 24147261      PMCID: PMC3801245          DOI: 10.5312/wjo.v4.i4.259

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  22 in total

1.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

2.  Accuracy and precision of radiostereometric analysis in the measurement of three-dimensional micromotion in a fracture model of the distal radius.

Authors:  Rami Madanat; Tatu J Mäkinen; Niko Moritz; Kimmo T Mattila; Hannu T Aro
Journal:  J Orthop Res       Date:  2005-03       Impact factor: 3.494

3.  Weight-bearing-induced displacement and migration over time of fracture fragments following split depression fractures of the lateral tibial plateau: a case series with radiostereometric analysis.

Authors:  L B Solomon; S A Callary; A W Stevenson; M A McGee; M J Chehade; D W Howie
Journal:  J Bone Joint Surg Br       Date:  2011-06

4.  Partial weight bearing after surgery for fractures of the lower extremity--is it achievable?

Authors:  Attila Vasarhelyi; Tobias Baumert; Christoph Fritsch; Werner Hopfenmüller; Georg Gradl; Thomas Mittlmeier
Journal:  Gait Posture       Date:  2006-01       Impact factor: 2.840

5.  Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliability of plain radiography versus computed tomography.

Authors:  R J Cole; R R Bindra; B A Evanoff; L A Gilula; K Yamaguchi; R H Gelberman
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

6.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

7.  Contact stress aberrations following imprecise reduction of simple tibial plateau fractures.

Authors:  T D Brown; D D Anderson; J V Nepola; R J Singerman; D R Pedersen; R A Brand
Journal:  J Orthop Res       Date:  1988       Impact factor: 3.494

8.  Physical activity in the United States measured by accelerometer.

Authors:  Richard P Troiano; David Berrigan; Kevin W Dodd; Louise C Mâsse; Timothy Tilert; Margaret McDowell
Journal:  Med Sci Sports Exerc       Date:  2008-01       Impact factor: 5.411

9.  Degenerative arthritis after tibial plateau fractures.

Authors:  S E Honkonen
Journal:  J Orthop Trauma       Date:  1995       Impact factor: 2.512

10.  Validation of the GENEA Accelerometer.

Authors:  Dale W Esliger; Ann V Rowlands; Tina L Hurst; Michael Catt; Peter Murray; Roger G Eston
Journal:  Med Sci Sports Exerc       Date:  2011-06       Impact factor: 5.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.