Literature DB >> 24140954

Cone beam CT imaging with limited angle of projections and prior knowledge for volumetric verification of non-coplanar beam radiation therapy: a proof of concept study.

Bowen Meng1, Lei Xing, Bin Han, Albert Koong, Daniel Chang, Jason Cheng, Ruijiang Li.   

Abstract

Non-coplanar beams are important for treatment of both cranial and noncranial tumors. Treatment verification of such beams with couch rotation/kicks, however, is challenging, particularly for the application of cone beam CT (CBCT). In this situation, only limited and unconventional imaging angles are feasible to avoid collision between the gantry, couch, patient, and on-board imaging system. The purpose of this work is to develop a CBCT verification strategy for patients undergoing non-coplanar radiation therapy. We propose an image reconstruction scheme that integrates a prior image constrained compressed sensing (PICCS) technique with image registration. Planning CT or CBCT acquired at the neutral position is rotated and translated according to the nominal couch rotation/translation to serve as the initial prior image. Here, the nominal couch movement is chosen to have a rotational error of 5° and translational error of 8 mm from the ground truth in one or more axes or directions. The proposed reconstruction scheme alternates between two major steps. First, an image is reconstructed using the PICCS technique implemented with total-variation minimization and simultaneous algebraic reconstruction. Second, the rotational/translational setup errors are corrected and the prior image is updated by applying rigid image registration between the reconstructed image and the previous prior image. The PICCS algorithm and rigid image registration are alternated iteratively until the registration results fall below a predetermined threshold. The proposed reconstruction algorithm is evaluated with an anthropomorphic digital phantom and physical head phantom. The proposed algorithm provides useful volumetric images for patient setup using projections with an angular range as small as 60°. It reduced the translational setup errors from 8 mm to generally <1 mm and the rotational setup errors from 5° to <1°. Compared with the PICCS algorithm alone, the integration of rigid registration significantly improved the reconstructed image quality, with a reduction of mostly 2-3 folds (up to 100) in root mean square image error. The proposed algorithm provides a remedy for solving the problem of non-coplanar CBCT reconstruction from limited angle of projections by combining the PICCS technique and rigid image registration in an iterative framework. In this proof of concept study, non-coplanar beams with couch rotations of 45° can be effectively verified with the CBCT technique.

Entities:  

Mesh:

Year:  2013        PMID: 24140954     DOI: 10.1088/0031-9155/58/21/7777

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Toward on-the-fly trajectory optimization for C-arm CBCT under strong kinematic constraints.

Authors:  Sepideh Hatamikia; Ander Biguri; Gernot Kronreif; Michael Figl; Tom Russ; Joachim Kettenbach; Martin Buschmann; Wolfgang Birkfellner
Journal:  PLoS One       Date:  2021-02-09       Impact factor: 3.240

2.  The Clinical Outcomes, Prognostic Factors and Nomogram Models for Primary Lung Cancer Patients Treated With Stereotactic Body Radiation Therapy.

Authors:  Li-Mei Luo; Ying Wang; Pei-Xian Lin; Chuang-Huang Su; Bao-Tian Huang
Journal:  Front Oncol       Date:  2022-03-01       Impact factor: 6.244

3.  Optimization for customized trajectories in cone beam computed tomography.

Authors:  Sepideh Hatamikia; Ander Biguri; Gernot Kronreif; Joachim Kettenbach; Tom Russ; Hugo Furtado; Lalith Kumar Shiyam Sundar; Martin Buschmann; Ewald Unger; Michael Figl; Dietmar Georg; Wolfgang Birkfellner
Journal:  Med Phys       Date:  2020-08-29       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.