Literature DB >> 24138185

A turn-on fluorescent sensor for sensitive and selective detection of sodium dodecyl sulfate based on the eosin Y/polyethyleneimine system.

Ting Wen1, Nian Bing Li, Hong Qun Luo.   

Abstract

A novel sensing system has been designed for the detection of sodium dodecyl sulfate (SDS) based on the recovered fluorescence signal of eosin Y and polyethyleneimine (PEI) complex. The eosin Y reacted with PEI to form a complex by virtue of hydrophobic interaction as well as the electrostatic interaction, which resulted in a strong fluorescence quenching of the eosin Y. Subsequently, with the addition of SDS to the eosin Y/PEI system, a strong surface interaction and electrostatic interactions between PEI and SDS resulted in the formation of the PEI/SDS complex and the dissociation of the eosin Y/PEI complex, which led to the significant fluorescence recovery. Herein, we have demonstrated that this facile methodology can offer a rapid, reliable, and selective detection of SDS with a detection limit as low as 0.02 μg mL(-1) and a linear range from 0.4 to 6 μg mL(-1). Furthermore, the method has been successfully applied to the detection of SDS in real samples with satisfied recovery and accuracy. Overall, these results demonstrate that this method has great promise for environmental applications.

Entities:  

Year:  2013        PMID: 24138185     DOI: 10.1021/ac402241m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Whole-cell electric sensor for determination of sodium dodecyl sulfate.

Authors:  Natalya S Velichko; Olga I Guliy; Matvei V Kanevsky; Maria A Kupryashina; Yulia P Fedonenko
Journal:  World J Microbiol Biotechnol       Date:  2022-05-26       Impact factor: 4.253

2.  A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots.

Authors:  Si-Si Liang; Xu Deng; Yao-Yao Fan; Jun Li; Man Wang; Zhi-Qi Zhang
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

3.  Quantitative determination and toxicity evaluation of 2,4-dichlorophenol using poly(eosin Y)/hydroxylated multi-walled carbon nanotubes modified electrode.

Authors:  Xiaolin Zhu; Kexin Zhang; Chengzhi Wang; Jiunian Guan; Xing Yuan; Baikun Li
Journal:  Sci Rep       Date:  2016-12-12       Impact factor: 4.379

4.  A resonance Rayleigh scattering sensor for sensitive differentiation of telomere DNA length and monitoring special motifs (G-quadruplex and i-motif) based on the Ag nanoclusters and NAND logic gate responding to chemical input signals.

Authors:  Shuai Wang; Fei Qu; Wenli Han; Jinmao You
Journal:  J Nanobiotechnology       Date:  2018-10-09       Impact factor: 10.435

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.