Literature DB >> 24136065

Dual-energy computed tomography compared with ultrasound in the diagnosis of gout.

Michael Gruber1, Gerd Bodner, Eva Rath, Gabriela Supp, Michael Weber, Claudia Schueller-Weidekamm.   

Abstract

OBJECTIVES: The aim of our study was to compare dual-energy CT (DECT) with US for the diagnosis of gouty arthritis and to correlate the imaging findings with results from synovial fluid aspiration whenever possible.
METHODS: We recruited 21 patients (17 male and 4 female) who presented with a clinical suspicion of acute or chronic gout in 37 joints. DECT scans of the hands, wrists, feet, ankles, knees and elbows were performed. For post-processing, a colour-coding gout software protocol was used. US examinations of the same joints were performed. In addition, joint fluid aspiration was performed in a total of 14 joints.
RESULTS: DECT images were positive for urate crystal deposits in 25 of 37 joints. US findings were positive in 24 of 37 examined joints. In 12 of 14 joints the synovial fluid aspiration was positive. CT and US findings correlated in 32 of 37 joints (86.5%; κ = 0.698, P < 0.001). CT and synovial fluid results correlated in 12 of 14 joints (85.7%; κ = 0.417, P = 0.119). US and cytology findings correlated in 14 of 14 joints (100%; κ = 1, P < 0.001).
CONCLUSION: DECT and US have comparable sensitivity for the detection of gouty arthritis in a clinical setting. However, DECT results should be interpreted carefully, as there could be some false-negative findings.

Entities:  

Keywords:  dual-energy CT; gout; gouty arthritis; synovial fluid; ultrasound

Mesh:

Year:  2013        PMID: 24136065     DOI: 10.1093/rheumatology/ket341

Source DB:  PubMed          Journal:  Rheumatology (Oxford)        ISSN: 1462-0324            Impact factor:   7.580


  20 in total

Review 1.  Imaging as an Outcome Measure in Gout Studies: Report from the OMERACT Gout Working Group.

Authors:  Rebecca Grainger; Nicola Dalbeth; Helen Keen; Laura Durcan; N Lawrence Edwards; Fernando Perez-Ruiz; Cesar Diaz-Torne; Jasvinder A Singh; Dinesh Khanna; Lee S Simon; William J Taylor
Journal:  J Rheumatol       Date:  2015-02-01       Impact factor: 4.666

Review 2.  Imaging in gout: A review of the recent developments.

Authors:  Priya Varghese Chowalloor; Teck K Siew; Helen Isobel Keen
Journal:  Ther Adv Musculoskelet Dis       Date:  2014-08       Impact factor: 5.346

Review 3.  An old disease with new insights: Update on diagnosis and treatment of gout.

Authors:  Berivan Bitik; M Akif Öztürk
Journal:  Eur J Rheumatol       Date:  2014-06-01

4.  Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout.

Authors:  Alexander Huppertz; Kay-Geert A Hermann; Torsten Diekhoff; Moritz Wagner; Bernd Hamm; Wolfgang A Schmidt
Journal:  Rheumatol Int       Date:  2014-03-12       Impact factor: 2.631

Review 5.  Current status of ultrasound and dual-energy computed tomography in the evaluation of gout.

Authors:  Hillary W Garner; Daniel E Wessell
Journal:  Rheumatol Int       Date:  2018-05-02       Impact factor: 2.631

6.  First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference.

Authors:  Torsten Diekhoff; Katharina Ziegeler; Eugen Feist; Tobias Kiefer; Jürgen Mews; Bernd Hamm; Kay-Geert A Hermann
Journal:  Skeletal Radiol       Date:  2015-07-05       Impact factor: 2.199

Review 7.  Hyperuricaemia with deposition: latest evidence and therapeutic approach.

Authors:  Fernando Perez-Ruiz; Estibaliz Marimon; Sandra P Chinchilla
Journal:  Ther Adv Musculoskelet Dis       Date:  2015-12       Impact factor: 5.346

8.  Ultrasound scans and dual energy CT identify tendons as preferred anatomical location of MSU crystal depositions in gouty joints.

Authors:  Yuan Yuan; Chang Liu; Xi Xiang; Tong-Ling Yuan; Li Qiu; Yi Liu; Yu-Bin Luo; Y Zhao; Martin Herrmann
Journal:  Rheumatol Int       Date:  2018-02-13       Impact factor: 2.631

Review 9.  The application of dual-energy computed tomography in the diagnosis of musculoskeletal disorders: a review of current concepts and applications.

Authors:  Marina Carotti; Fausto Salaffi; Giacomo Beci; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-03-04       Impact factor: 3.469

10.  Reliability of a new scoring system for intraarticular mineralization of the knee: Boston University Calcium Knee Score (BUCKS).

Authors:  A Guermazi; M Jarraya; J A Lynch; D T Felson; M Clancy; M Nevitt; C E Lewis; J Torner; T Neogi
Journal:  Osteoarthritis Cartilage       Date:  2020-03-12       Impact factor: 6.576

View more