OBJECTIVE: To assess critical heat spread of cautery instruments used in robot-assisted laparoscopic (RAL) surgery. MATERIALS AND METHODS: Thermal spread along bovine musculofascial tissues was examined by infrared camera, histology and enzyme assay. Currently used monopolar, bipolar and ultrasonic laparoscopic instruments were investigated at various power settings and application times. The efficacy of using an additional Maryland clamp as a heat sink was evaluated. A temperature of 45 °C was considered the threshold temperature for possible nerve damage. RESULTS: Monopolar instruments exhibited a mean (sem) critical thermal spread of 3.5 (2.3) mm when applied at 60 W for 1 s. After 2 s, the spread was >20 mm. For adjustable bipolar instruments the mean (sem) critical thermal spread was 2.2 (0.6) mm at 60 W and 1 s, and 3.6 (1.3) mm at 2 s. The PK and LigaSure forceps had mean (sem) critical thermal spreads of 3.9 (0.8) and 2.8 (0.6) mm respectively, whereas the ultrasonic instrument reached 2.9 (0.8) mm. Application of an additional Maryland clamp as a heat sink, significantly reduced the thermal spread. Histomorphometric analyses and enzyme assay supported these findings. CONCLUSIONS: All coagulation devices used in RAL surgery have distinct thermal spreads depending on power setting and application time. Cautery may be of concern due to lateral temperature spread, causing potential damage to sensitive structures including nerves. Our results provide surgeons with a resource for educated decision-making when using coagulation devices during robotic procedures.
OBJECTIVE: To assess critical heat spread of cautery instruments used in robot-assisted laparoscopic (RAL) surgery. MATERIALS AND METHODS: Thermal spread along bovine musculofascial tissues was examined by infrared camera, histology and enzyme assay. Currently used monopolar, bipolar and ultrasonic laparoscopic instruments were investigated at various power settings and application times. The efficacy of using an additional Maryland clamp as a heat sink was evaluated. A temperature of 45 °C was considered the threshold temperature for possible nerve damage. RESULTS: Monopolar instruments exhibited a mean (sem) critical thermal spread of 3.5 (2.3) mm when applied at 60 W for 1 s. After 2 s, the spread was >20 mm. For adjustable bipolar instruments the mean (sem) critical thermal spread was 2.2 (0.6) mm at 60 W and 1 s, and 3.6 (1.3) mm at 2 s. The PK and LigaSure forceps had mean (sem) critical thermal spreads of 3.9 (0.8) and 2.8 (0.6) mm respectively, whereas the ultrasonic instrument reached 2.9 (0.8) mm. Application of an additional Maryland clamp as a heat sink, significantly reduced the thermal spread. Histomorphometric analyses and enzyme assay supported these findings. CONCLUSIONS: All coagulation devices used in RAL surgery have distinct thermal spreads depending on power setting and application time. Cautery may be of concern due to lateral temperature spread, causing potential damage to sensitive structures including nerves. Our results provide surgeons with a resource for educated decision-making when using coagulation devices during robotic procedures.
Authors: Sam Van Slycke; Jean-Pierre Gillardin; Klaas Van Den Heede; Joan Minguet; Hubert Vermeersch; Nele Brusselaers Journal: Langenbecks Arch Surg Date: 2016-05-25 Impact factor: 3.445
Authors: Heiko Aselmann; Jan-Niclas Kersebaum; Alexander Bernsmeier; Jan Henrik Beckmann; Thorben Möller; Jan Hendrik Egberts; Clemens Schafmayer; Christoph Röcken; Thomas Becker Journal: Int J Colorectal Dis Date: 2018-07-04 Impact factor: 2.571
Authors: Philip C Müller; Daniel C Steinemann; Lukas Chinczewski; Gencay Hatiboglu; Felix Nickel; Kaspar Z'graggen; Beat P Müller-Stich Journal: Surg Endosc Date: 2018-05-01 Impact factor: 4.584
Authors: Judith Olde Heuvel; Berlinda J de Wit-van der Veen; Henk G van der Poel; Pim J van Leeuwen; Elise M Bekers; Maarten R Grootendorst; Kunal N Vyas; Cornelis H Slump; Marcel P M Stokkel Journal: J Nucl Med Date: 2021-04-30 Impact factor: 11.082