Literature DB >> 24124968

A new test strip technology platform for self-monitoring of blood glucose.

Robert Bernstein1, Joan Lee Parkes, Amy Goldy, Daniel Brown, Bern Harrison, Amy Chu, Brian K Pflug, David A Simmons, Scott Pardo, Timothy S Bailey.   

Abstract

In the management of diabetes, accuracy of devices used for self-monitoring of blood glucose (SMBG) is critical because SMBG results can affect patient diabetes-related health outcomes. A new blood glucose monitoring system (BGMS) platform has been developed that is based on the new CONTOUR® NEXT (CN) test strip. This BGMS platform uses a proprietary electron mediator and algorithm to minimize errors at different steps in the testing process, thus minimizing outliers and significantly improving accuracy from prior-generation blood glucose meter systems. As demonstrated by questionnaire results from clinical studies with the new BGMS platform, accuracy and ease of use are important considerations for people with diabetes and their health care professionals when selecting an SMBG device. This article provides an overview of laboratory studies and clinical trials in the hands of lay users involving the performance of the portfolio of blood glucose meters that uses the new test strip. Each BGMS in the platform, which includes the CONTOUR XT (CONTOUR NEXT EZ in the United States), CONTOUR NEXT LINK, CONTOUR NEXT USB, and CN systems, demonstrated advanced accuracy both in the laboratory and in the hands of subjects (people with diabetes) and trained health care professionals. All systems met and exceeded International Organization for Standardization accuracy criteria (both ISO 15197:2003 and ISO 15197:2013). Each system in the new BGMS platform delivers advanced accuracy, which is essential to people who utilize SMBG for improved management.
© 2013 Diabetes Technology Society.

Entities:  

Mesh:

Year:  2013        PMID: 24124968      PMCID: PMC3876385          DOI: 10.1177/193229681300700531

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  15 in total

1.  A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose.

Authors:  J L Parkes; S L Slatin; S Pardo; B H Ginsberg
Journal:  Diabetes Care       Date:  2000-08       Impact factor: 19.112

Review 2.  Standards of medical care in diabetes--2012.

Authors: 
Journal:  Diabetes Care       Date:  2012-01       Impact factor: 19.112

3.  Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes registry.

Authors:  A J Karter; L M Ackerson; J A Darbinian; R B D'Agostino; A Ferrara; J Liu; J V Selby
Journal:  Am J Med       Date:  2001-07       Impact factor: 4.965

4.  Performance of a new blood glucose monitoring system in the hands of intended users.

Authors:  Timothy S Bailey; Jane F Wallace; Joan Lee Parkes; Scott Pardo; Ji Yu; Holly C Schachner; David A Simmons; Amy Chu
Journal:  Diabetes Technol Ther       Date:  2012-06-29       Impact factor: 6.118

5.  Glucose meter inaccuracy and the impact on the care of patients.

Authors:  Richard Hellman
Journal:  Diabetes Metab Res Rev       Date:  2012-03       Impact factor: 4.876

6.  ROSES: role of self-monitoring of blood glucose and intensive education in patients with Type 2 diabetes not receiving insulin. A pilot randomized clinical trial.

Authors:  M Franciosi; G Lucisano; F Pellegrini; A Cantarello; A Consoli; L Cucco; R Ghidelli; G Sartore; L Sciangula; A Nicolucci
Journal:  Diabet Med       Date:  2011-07       Impact factor: 4.359

7.  Self-monitoring of blood glucose. American Diabetes Association.

Authors: 
Journal:  Diabetes Care       Date:  1994-01       Impact factor: 19.112

8.  Consensus report: the current role of self-monitoring of blood glucose in non-insulin-treated type 2 diabetes.

Authors:  David C Klonoff; Lawrence Blonde; George Cembrowski; Antonio Roberto Chacra; Guillaume Charpentier; Stephen Colagiuri; George Dailey; Robert A Gabbay; Lutz Heinemann; David Kerr; Antonio Nicolucci; William Polonsky; Oliver Schnell; Robert Vigersky; Jean-François Yale
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

9.  The food and drug administration is now preparing to establish tighter performance requirements for blood glucose monitors.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

10.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

View more
  9 in total

1.  System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method.

Authors:  Manuela Link; Christina Schmid; Stefan Pleus; Annette Baumstark; Delia Rittmeyer; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2015-04-14

2.  Analysis of "Capillary and Venous Blood Glucose Accuracy in Blood Glucose Meters Versus Reference Standards: The Impact of Study Design on Accuracy Evaluations".

Authors:  Gary H Thorpe
Journal:  J Diabetes Sci Technol       Date:  2018-09-15

3.  Performance of a Blood Glucose Monitoring System in a Point-of-Care Setting.

Authors:  Cornelia Ottiger; Nicole Gygli; Andreas R Huber; Beatriz Fernandez-Tresguerres; Scott Pardo; Thorsten Petruschke
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

4.  Impact of Xylose on Glucose-Dehydrogenase-Based Blood Glucose Meters for Patient Self-Testing.

Authors:  Andreas Pfützner; Filiz Demircik; Daniela Sachsenheimer; Jan Spatz; Anke H Pfützner; Sanja Ramljak
Journal:  J Diabetes Sci Technol       Date:  2016-11-15

5.  Accuracy and User Performance of a New Blood Glucose Monitoring System.

Authors:  Leslie Klaff; Pragathi Shelat; Diana Zondorak; Amy Wayland-Smith; Phil Vernes; James M Richardson
Journal:  J Diabetes Sci Technol       Date:  2020-11-26

6.  A Multicenter Performance Evaluation of a Blood Glucose Monitoring System in 21 Leading Hospitals in Spain.

Authors:  José Luis Bedini; Jane F Wallace; Thorsten Petruschke; Scott Pardo
Journal:  J Diabetes Sci Technol       Date:  2015-08-07

7.  Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program.

Authors:  Anna K Füzéry; George S Cembrowski
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

8.  The Norwegian dietary guidelines and colorectal cancer survival (CRC-NORDIET) study: a food-based multicentre randomized controlled trial.

Authors:  Hege Berg Henriksen; Hanna Ræder; Siv Kjølsrud Bøhn; Ingvild Paur; Ane Sørlie Kværner; Siv Åshild Billington; Morten Tandberg Eriksen; Gro Wiedsvang; Iris Erlund; Arne Færden; Marit Bragelien Veierød; Manuela Zucknick; Sigbjørn Smeland; Rune Blomhoff
Journal:  BMC Cancer       Date:  2017-01-30       Impact factor: 4.430

9.  Effect of Cognitive Behavioral Therapy for Insomnia on Insomnia Symptoms for Individuals With Type 2 Diabetes: Protocol for a Pilot Randomized Controlled Trial.

Authors:  Mohammed M Alshehri; Aqeel M Alenazi; Jeffrey C Hoover; Shaima A Alothman; Milind A Phadnis; Christie A Befort; John M Miles; Jason L Rucker; Patricia M Kluding; Catherine F Siengsukon
Journal:  JMIR Res Protoc       Date:  2019-12-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.