Literature DB >> 24120167

A microfluidic paper-based analytical device for rapid quantification of particulate chromium.

Poomrat Rattanarat1, Wijitar Dungchai, David M Cate, Weena Siangproh, John Volckens, Orawon Chailapakul, Charles S Henry.   

Abstract

Occupational exposure to Cr is concerning because of its myriad of health effects. Assessing chromium exposure is also cost and resource intensive because the analysis typically uses sophisticated instrumental techniques like inductively coupled plasma-mass spectrometry (ICP-MS). Here, we report a novel, simple, inexpensive microfluidic paper-based analytical device (μPAD) for measuring total Cr in airborne particulate matter. In the μPAD, tetravalent cerium (Ce(IV)) was used in a pretreatment zone to oxidize all soluble Cr to Cr(VI). After elution to the detection zone, Cr(VI) reacts with 1,5-diphenylcarbazide (1,5-DPC) forming 1,5-diphenylcarbazone (DPCO) and Cr(III). The resulting Cr(III) forms a distinct purple colored complex with the DPCO. As proof-of-principle, particulate matter (PM) collected on a sample filter was analyzed with the μPAD to quantify the mass of total Cr. A log-linear working range (0.23-3.75 μg; r(2)=0.998) between Cr and color intensity was obtained with a detection limit of 0.12 μg. For validation, a certified reference containing multiple competing metals was analyzed. Quantitative agreement was obtained between known Cr levels in the sample and the Cr measured using the μPAD.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chromium; Microfluidics; Paper-based analytical device; Particulate matter

Mesh:

Substances:

Year:  2013        PMID: 24120167      PMCID: PMC3842604          DOI: 10.1016/j.aca.2013.09.008

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  30 in total

1.  Abnormal trace metals in man--chromium.

Authors:  H A SCHROEDER; J J BALASSA; I H TIPTON
Journal:  J Chronic Dis       Date:  1962-10

2.  Use of multiple colorimetric indicators for paper-based microfluidic devices.

Authors:  Wijitar Dungchai; Orawon Chailapakul; Charles S Henry
Journal:  Anal Chim Acta       Date:  2010-06-25       Impact factor: 6.558

3.  Understanding wax printing: a simple micropatterning process for paper-based microfluidics.

Authors:  Emanuel Carrilho; Andres W Martinez; George M Whitesides
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

4.  Determination of chromium(VI) by surface plasmon field-enhanced resonance light scattering.

Authors:  Zhiqiang Han; Li Qi; Gangyi Shen; Wei Liu; Yi Chen
Journal:  Anal Chem       Date:  2007-06-22       Impact factor: 6.986

5.  X-ray fluorescence analysis of hexavalent chromium using Kβ satellite peak observed as counterpart of X-ray absorption near-edge structure pre-edge peak.

Authors:  Isao Tsuyumoto; Yoshihiro Maruyama
Journal:  Anal Chem       Date:  2011-09-06       Impact factor: 6.986

6.  Measuring markers of liver function using a micropatterned paper device designed for blood from a fingerstick.

Authors:  Sarah J Vella; Patrick Beattie; Rebecca Cademartiri; Anna Laromaine; Andres W Martinez; Scott T Phillips; Katherine A Mirica; George M Whitesides
Journal:  Anal Chem       Date:  2012-03-02       Impact factor: 6.986

7.  Role of 5-thio-(2-nitrobenzoic acid)-capped gold nanoparticles in the sensing of chromium(vi): remover and sensor.

Authors:  Yi-Jhen Lai; Wei-Lung Tseng
Journal:  Analyst       Date:  2011-05-18       Impact factor: 4.616

8.  Novel, highly selective detection of Cr(III) in aqueous solution based on a gold nanoparticles colorimetric assay and its application for determining Cr(VI).

Authors:  Liang Zhao; Yin Jin; Zhangwei Yan; Yuanyuan Liu; Hongjun Zhu
Journal:  Anal Chim Acta       Date:  2012-04-25       Impact factor: 6.558

9.  Reagentless bidirectional lateral flow bioactive paper sensors for detection of pesticides in beverage and food samples.

Authors:  S M Zakir Hossain; Roger E Luckham; Meghan J McFadden; John D Brennan
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

Review 10.  Recent advances in paper-based sensors.

Authors:  Devi D Liana; Burkhard Raguse; J Justin Gooding; Edith Chow
Journal:  Sensors (Basel)       Date:  2012-08-24       Impact factor: 3.576

View more
  12 in total

1.  Speciation of chromium in water samples using microfluidic paper-based analytical devices with online oxidation of trivalent chromium.

Authors:  Abdellah Muhammed; Ahmed Hussen; Takashi Kaneta
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

2.  Disposable paper-based electrochemical sensor using thiol-terminated poly(2-methacryloyloxyethyl phosphorylcholine) for the label-free detection of C-reactive protein.

Authors:  Chanika Pinyorospathum; Sudkate Chaiyo; Pornpen Sae-Ung; Voravee P Hoven; Panittha Damsongsang; Weena Siangproh; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2019-06-26       Impact factor: 5.833

3.  The Yxy colour space parameters as novel signalling tools for digital imaging sensors in the analytical laboratory.

Authors:  Ashraf A Mohamed; Ahmed A Shalaby; Abdelnaby M Salem
Journal:  RSC Adv       Date:  2018-03-16       Impact factor: 4.036

Review 4.  New Methods for Personal Exposure Monitoring for Airborne Particles.

Authors:  Kirsten A Koehler; Thomas M Peters
Journal:  Curr Environ Health Rep       Date:  2015-12

Review 5.  Enabling robust quantitative readout in an equipment-free model of device development.

Authors:  Elain Fu
Journal:  Analyst       Date:  2014-10-07       Impact factor: 4.616

6.  Highly selective simultaneous determination of Cu(ii), Co(ii), Ni(ii), Hg(ii), and Mn(ii) in water samples using microfluidic paper-based analytical devices.

Authors:  Pornphimon Kamnoet; Wanlapa Aeungmaitrepirom; Ruth F Menger; Charles S Henry
Journal:  Analyst       Date:  2021-02-17       Impact factor: 4.616

Review 7.  Paper-based analytical devices for environmental analysis.

Authors:  Nathan A Meredith; Casey Quinn; David M Cate; Thomas H Reilly; John Volckens; Charles S Henry
Journal:  Analyst       Date:  2016-03-21       Impact factor: 5.227

8.  Influence of Geometry and Surrounding Conditions on Fluid Flow in Paper-Based Devices.

Authors:  Noosheen Walji; Brendan D MacDonald
Journal:  Micromachines (Basel)       Date:  2016-04-25       Impact factor: 2.891

9.  Improving Sustainability of the Griess Reaction by Reagent Stabilization on PDMS Membranes and ZnNPs as Reductor of Nitrates: Application to Different Water Samples.

Authors:  Lusine Hakobyan; Belén Monforte-Gómez; Yolanda Moliner-Martínez; Carmen Molins-Legua; Pilar Campíns-Falcó
Journal:  Polymers (Basel)       Date:  2022-01-24       Impact factor: 4.329

10.  Rapid detection of transition metals in welding fumes using paper-based analytical devices.

Authors:  David M Cate; Pavisara Nanthasurasak; Pornpak Riwkulkajorn; Christian L'Orange; Charles S Henry; John Volckens
Journal:  Ann Occup Hyg       Date:  2014-02-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.