Literature DB >> 20678634

Use of multiple colorimetric indicators for paper-based microfluidic devices.

Wijitar Dungchai1, Orawon Chailapakul, Charles S Henry.   

Abstract

We report here the use of multiple indicators for a single analyte for paper-based microfluidic devices (microPAD) in an effort to improve the ability to visually discriminate between analyte concentrations. In existing microPADs, a single dye system is used for the measurement of a single analyte. In our approach, devices are designed to simultaneously quantify analytes using multiple indicators for each analyte improving the accuracy of the assay. The use of multiple indicators for a single analyte allows for different indicator colors to be generated at different analyte concentration ranges as well as increasing the ability to better visually discriminate colors. The principle of our devices is based on the oxidation of indicators by hydrogen peroxide produced by oxidase enzymes specific for each analyte. Each indicator reacts at different peroxide concentrations and therefore analyte concentrations, giving an extended range of operation. To demonstrate the utility of our approach, the mixture of 4-aminoantipyrine and 3,5-dichloro-2-hydroxy-benzenesulfonic acid, o-dianisidine dihydrochloride, potassium iodide, acid black, and acid yellow were chosen as the indicators for simultaneous semi-quantitative measurement of glucose, lactate, and uric acid on a microPAD. Our approach was successfully applied to quantify glucose (0.5-20 mM), lactate (1-25 mM), and uric acid (0.1-7 mM) in clinically relevant ranges. The determination of glucose, lactate, and uric acid in control serum and urine samples was also performed to demonstrate the applicability of this device for biological sample analysis. Finally results for the multi-indicator and single indicator system were compared using untrained readers to demonstrate the improvements in accuracy achieved with the new system. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20678634     DOI: 10.1016/j.aca.2010.06.019

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  54 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

2.  Perspective on diagnostics for global health.

Authors:  Elain Fu; Paul Yager; Pierre N Floriano; Nicolaos Christodoulides; John T McDevitt
Journal:  IEEE Pulse       Date:  2011-11       Impact factor: 0.924

3.  Enhanced sensitivity of lateral flow tests using a two-dimensional paper network format.

Authors:  Elain Fu; Tinny Liang; Jared Houghtaling; Sujatha Ramachandran; Stephen A Ramsey; Barry Lutz; Paul Yager
Journal:  Anal Chem       Date:  2011-09-21       Impact factor: 6.986

4.  A perspective on paper-based microfluidics: Current status and future trends.

Authors:  Xu Li; David R Ballerini; Wei Shen
Journal:  Biomicrofluidics       Date:  2012-03-02       Impact factor: 2.800

5.  Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection.

Authors:  Elain Fu; Tinny Liang; Paolo Spicar-Mihalic; Jared Houghtaling; Sujatha Ramachandran; Paul Yager
Journal:  Anal Chem       Date:  2012-04-26       Impact factor: 6.986

Review 6.  Paper-based analytical devices for point-of-care infectious disease testing.

Authors:  C Rozand
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-08-25       Impact factor: 3.267

7.  A microfluidic paper-based analytical device for rapid quantification of particulate chromium.

Authors:  Poomrat Rattanarat; Wijitar Dungchai; David M Cate; Weena Siangproh; John Volckens; Orawon Chailapakul; Charles S Henry
Journal:  Anal Chim Acta       Date:  2013-09-12       Impact factor: 6.558

8.  Rapid evaporation-driven chemical pre-concentration and separation on paper.

Authors:  Richard Syms
Journal:  Biomicrofluidics       Date:  2017-08-24       Impact factor: 2.800

9.  Microfluidic paper-based analytical device for aerosol oxidative activity.

Authors:  Yupaporn Sameenoi; Pantila Panymeesamer; Natcha Supalakorn; Kirsten Koehler; Orawon Chailapakul; Charles S Henry; John Volckens
Journal:  Environ Sci Technol       Date:  2012-12-21       Impact factor: 9.028

10.  Construction and electrochemical characterization of microelectrodes for improved sensitivity in paper-based analytical devices.

Authors:  Murilo Santhiago; John B Wydallis; Lauro T Kubota; Charles S Henry
Journal:  Anal Chem       Date:  2013-05-01       Impact factor: 6.986

View more