Literature DB >> 24117454

Flow dynamics of different adult ECMO systems: a clinical evaluation.

Karla Lehle1, Alois Philipp, Thomas Müller, Frank Schettler, Thomas Bein, Christof Schmid, Matthias Lubnow.   

Abstract

Membrane oxygenator (MO) failure is a known hazard during venovenous extracorporeal membrane oxygenation (v-v ECMO) therapy. Knowledge about technical and performance details of different ECMO systems (Maquet, Rastatt, Germany; Medos, Stolberg, Germany; Sorin, Modena, Italy) licensed for adults with acute lung failure might improve their handling. This retrospective study comprises 186 adult patients (Regensburg ECMO Registry) treated with v-v ECMO. Flow dynamic data were used to analyze the performance of different blood pumps, cannula types, and MOs to maintain an adequate blood flow (1-5 L/min). Usage of the Medos ECMO system in critically ill patients required a higher pump speed and generated a higher pressure drop across the MO (dpMO), however, without an increase in free plasma hemoglobin. The dpMO depended on the type of MO and increased with blood flow as expected. Type-specific normal values are reported. A distinct increase in dpMO above normal values within 1 day required an immediate MO exchange. This was an infrequent technical complication (3%). Finally, pressure-flow performance of single dual-lumen cannulas (27 Fr) was comparable with small single-lumen cannulas (15 Fr), without an increased risk of technical-induced hemolysis. Despite different performances, all current commercially available adult v-v ECMO systems produce adequate blood flow without an increased risk in technical-induced hemolysis. Familiarity with the specific properties of individual systems allows early detection of technical complications. Additionally, the choice of an adequate cannula requires a closer consideration of the individual patient situation.
Copyright © 2013 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Extracorporeal membrane oxygenation; Flow dynamics; Inflow cannula diameter; Oxygenator exchange; Pressure difference; Technical complications; Technical-induced hemolysis

Mesh:

Year:  2013        PMID: 24117454     DOI: 10.1111/aor.12180

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  9 in total

1.  Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: analysis of 317 cases with four different ECMO systems.

Authors:  Karla Lehle; Alois Philipp; Karl-Anton Hiller; Florian Zeman; Dirk Buchwald; Christof Schmid; Christian Dornia; Dirk Lunz; Thomas Müller; Matthias Lubnow
Journal:  Intensive Care Med       Date:  2014-10-17       Impact factor: 17.440

2.  Technical complications during veno-venous extracorporeal membrane oxygenation and their relevance predicting a system-exchange--retrospective analysis of 265 cases.

Authors:  Matthias Lubnow; Alois Philipp; Maik Foltan; Tone Bull Enger; Dirk Lunz; Thomas Bein; Assad Haneya; Christof Schmid; Günter Riegger; Thomas Müller; Karla Lehle
Journal:  PLoS One       Date:  2014-12-02       Impact factor: 3.240

3.  Risk Factors for Acute Kidney Injury and In-Hospital Mortality in Patients Receiving Extracorporeal Membrane Oxygenation.

Authors:  Sung Woo Lee; Mi-Yeon Yu; Hajeong Lee; Shin Young Ahn; Sejoong Kim; Ho Jun Chin; Ki Young Na
Journal:  PLoS One       Date:  2015-10-15       Impact factor: 3.240

Review 4.  Adult venovenous extracorporeal membrane oxygenation for severe respiratory failure: Current status and future perspectives.

Authors:  Ayan Sen; Hannelisa E Callisen; Cory M Alwardt; Joel S Larson; Amelia A Lowell; Stacy L Libricz; Pritee Tarwade; Bhavesh M Patel; Harish Ramakrishna
Journal:  Ann Card Anaesth       Date:  2016 Jan-Mar

5.  Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice.

Authors:  Alois Philipp; Filip De Somer; Maik Foltan; Andre Bredthauer; Lars Krenkel; Florian Zeman; Karla Lehle
Journal:  PLoS One       Date:  2018-06-01       Impact factor: 3.240

6.  Factors associated with hemolysis during extracorporeal membrane oxygenation (ECMO)-Comparison of VA- versus VV ECMO.

Authors:  Hannah Appelt; Alois Philipp; Thomas Mueller; Maik Foltan; Matthias Lubnow; Dirk Lunz; Florian Zeman; Karla Lehle
Journal:  PLoS One       Date:  2020-01-27       Impact factor: 3.240

7.  The effect of flow and pressure on the intraoxygenator flow path of different contemporary oxygenators: an in vitro trial.

Authors:  Rik Hj Hendrix; Alexander Ks Yeung; Yuri M Ganushchak; Patrick W Weerwind
Journal:  Perfusion       Date:  2020-02-14       Impact factor: 1.972

Review 8.  Current Understanding of Leukocyte Phenotypic and Functional Modulation During Extracorporeal Membrane Oxygenation: A Narrative Review.

Authors:  Katrina K Ki; Jonathan E Millar; Daman Langguth; Margaret R Passmore; Charles I McDonald; Kiran Shekar; Manu Shankar-Hari; Hwa Jin Cho; Jacky Y Suen; John F Fraser
Journal:  Front Immunol       Date:  2021-01-08       Impact factor: 7.561

9.  Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO - Prevalence and Risk Factors.

Authors:  Karla Lehle; Alois Philipp; Florian Zeman; Dirk Lunz; Matthias Lubnow; Hans-Peter Wendel; Laszlo Göbölös; Christof Schmid; Thomas Müller
Journal:  PLoS One       Date:  2015-11-25       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.