Literature DB >> 24113058

Combined recipe for clinical target volume and planning target volume margins.

Joep Stroom1, Kenneth Gilhuijs2, Sandra Vieira3, Wei Chen4, Javier Salguero4, Elizabeth Moser3, Jan-Jakob Sonke4.   

Abstract

PURPOSE: To develop a combined recipe for clinical target volume (CTV) and planning target volume (PTV) margins. METHODS AND MATERIALS: A widely accepted PTV margin recipe is M(geo) = aΣ(geo) + bσ(geo), with Σ(geo) and σ(geo) standard deviations (SDs) representing systematic and random geometric uncertainties, respectively. On the basis of histopathology data of breast and lung tumors, we suggest describing the distribution of microscopic islets around the gross tumor volume (GTV) by a half-Gaussian with SD Σ(micro), yielding as possible CTV margin recipe: M(micro) = ƒ(N(i)) × Σ(micro), with N(i) the average number of microscopic islets per patient. To determine ƒ(N(i)), a computer model was developed that simulated radiation therapy of a spherical GTV with isotropic distribution of microscopic disease in a large group of virtual patients. The minimal margin that yielded D(min) <95% in maximally 10% of patients was calculated for various Σ(micro) and N(i). Because Σ(micro) is independent of Σ(geo), we propose they should be added quadratically, yielding for a combined GTV-to-PTV margin recipe: M(GTV-PTV) = √{[aΣ(geo)](2) + [ƒ(N(i))Σ(micro)](2)} + bσ(geo). This was validated by the computer model through numerous simultaneous simulations of microscopic and geometric uncertainties.
RESULTS: The margin factor ƒ(N(i)) in a relevant range of Σ(micro) and N(i) can be given by: ƒ(N(i)) = 1.4 + 0.8log(N(i)). Filling in the other factors found in our simulations (a = 2.1 and b = 0.8) yields for the combined recipe: M(GTV-PTV) = √({2.1Σ(geo)}(2) + {[1.4 + 0.8log(N(i))] × Σ(micro)}(2)) + 0.8σ(geo). The average margin difference between the simultaneous simulations and the above recipe was 0.2 ± 0.8 mm (1 SD). Calculating M(geo) and M(micro) separately and adding them linearly overestimated PTVs by on average 5 mm. Margin recipes based on tumor control probability (TCP) instead of D(min) criteria yielded similar results.
CONCLUSIONS: A general recipe for GTV-to-PTV margins is proposed, which shows that CTV and PTV margins should be added in quadrature instead of linearly.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24113058     DOI: 10.1016/j.ijrobp.2013.08.028

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  7 in total

Review 1.  Radiation oncology in the era of precision medicine.

Authors:  Michael Baumann; Mechthild Krause; Jens Overgaard; Jürgen Debus; Søren M Bentzen; Juliane Daartz; Christian Richter; Daniel Zips; Thomas Bortfeld
Journal:  Nat Rev Cancer       Date:  2016-03-18       Impact factor: 60.716

2.  An image-guided study of setup reproducibility of postmastectomy breast cancer patients treated with inverse-planned intensity modulated radiation therapy.

Authors:  Christine H Feng; Emily Gerry; Steven J Chmura; Yasmin Hasan; Hania A Al-Hallaq
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-10-22       Impact factor: 7.038

3.  Clinical Target Volume: The Third Front.

Authors:  Leonard Kim; Cuihuan Wang; Atif Khan; Mark Pierce
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-04       Impact factor: 7.038

4.  On the determination of planning target margins due to motion for mice lung tumours using a four-dimensional MOBY phantom.

Authors:  Ana Vaniqui; Brent van der Heyden; Isabel P Almeida; Lotte Ejr Schyns; Stefan J van Hoof; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-07-20       Impact factor: 3.039

5.  Evaluation of OAR dose sparing and plan robustness of beam-specific PTV in lung cancer IMRT treatment.

Authors:  Yu Chang; Feng Xiao; Hong Quan; Zhiyong Yang
Journal:  Radiat Oncol       Date:  2020-10-17       Impact factor: 3.481

6.  Ramifications of Setup Margin Use During Frameless Stereotactic Radiosurgery/Therapy With Gamma Knife Icon Cone-Beam Computed Tomography (CBCT): A Dosimetric Study.

Authors:  William N Duggar; Bart Morris; Rui He; Claus Chunli Yang
Journal:  Cureus       Date:  2022-02-07

7.  New target volume delineation and PTV strategies to further personalise radiotherapy.

Authors:  David Bernstein; Alexandra Taylor; Simeon Nill; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2021-02-25       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.