Literature DB >> 24111132

Wearable cuff-less PTT-based system for overnight blood pressure monitoring.

Yali Zheng, Bryan P Yan, Yuanting Zhang, C M Yu, Carmen C Y Poon.   

Abstract

A wearable cuff-less pulse transit time (PTT) based monitoring device is developed for ambulatory blood pressure (BP) monitoring. Ten healthy subjects (aged 27 ± 4 years old) underwent 24-hour ambulatory BP monitoring using 1) a standard brachial cuff-based oscillometric device as reference and 2) the proposed cuff-less PTT measuring system. Raw PTT and BP measurements were linearly interpolated and then smoothed by a low-pass filter to remove aliasing effect caused by the low sampling rate and synchronized. Resampled PTT and BP were assessed for correlation using correlation coefficients and Bland-Altman plots. Our study showed that PTT estimated systolic BP most accurately within 4.8 ± 4.3 mmHg on healthy young subjects during sleep time. We conclude from this study that the proposed cuff-less PTT-based BP monitoring system has potential to be a less intrusive alternative to standard oscillometric method for long-term overnight BP monitoring.

Mesh:

Year:  2013        PMID: 24111132     DOI: 10.1109/EMBC.2013.6610945

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

Authors:  Kimberly C Blom; Sasha Farina; Yessica-Haydee Gomez; Norm R C Campbell; Brenda R Hemmelgarn; Lyne Cloutier; Donald W McKay; Martin Dawes; Sheldon W Tobe; Peter Bolli; Mark Gelfer; Donna McLean; Gillian Bartlett; Lawrence Joseph; Robin Featherstone; Ernesto L Schiffrin; Stella S Daskalopoulou
Journal:  Curr Hypertens Rep       Date:  2015-04       Impact factor: 5.369

2.  Cuffless Blood Pressure Estimation Based on Data-Oriented Continuous Health Monitoring System.

Authors:  Kengo Atomi; Haruki Kawanaka; Md Shoaib Bhuiyan; Koji Oguri
Journal:  Comput Math Methods Med       Date:  2017-04-24       Impact factor: 2.238

3.  Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System.

Authors:  Vega Pradana Rachim; Wan-Young Chung
Journal:  Sci Rep       Date:  2019-05-28       Impact factor: 4.379

4.  Non-Invasive Device for Blood Pressure Wave Acquisition by Means of Mechanical Transducer.

Authors:  David Zambrana-Vinaroz; Jose Maria Vicente-Samper; Carlos G Juan; Vicente Esteve-Sala; Jose Maria Sabater-Navarro
Journal:  Sensors (Basel)       Date:  2019-10-05       Impact factor: 3.576

Review 5.  Recent advances in selective photothermal therapy of tumor.

Authors:  Liping Zhao; Xu Zhang; Xiaoxia Wang; Xiuwen Guan; Weifeng Zhang; Jinlong Ma
Journal:  J Nanobiotechnology       Date:  2021-10-24       Impact factor: 10.435

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.