Literature DB >> 24110980

Validation of a wrist monitor for accurate estimation of RR intervals during sleep.

Ph Renevey, J Sola, P Theurillat, M Bertschi, J Krauss, D Andries, C Sartori.   

Abstract

While the incidence of sleep disorders is continuously increasing in western societies, there is a clear demand for technologies to asses sleep-related parameters in ambulatory scenarios. The present study introduces a novel concept of accurate sensor to measure RR intervals via the analysis of photo-plethysmographic signals recorded at the wrist. In a cohort of 26 subjects undergoing full night polysomnography, the wrist device provided RR interval estimates in agreement with RR intervals as measured from standard electrocardiographic time series. The study showed an overall agreement between both approaches of 0.05 ± 18 ms. The novel wrist sensor opens the door towards a new generation of comfortable and easy-to-use sleep monitors.

Entities:  

Mesh:

Year:  2013        PMID: 24110980     DOI: 10.1109/EMBC.2013.6610793

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor.

Authors:  Jarkko Harju; Antti Vehkaoja; Ville Lindroos; Pekka Kumpulainen; Sasu Liuhanen; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2016-10-17       Impact factor: 2.502

2.  Actigraphy to Measure Physical Activity in the Intensive Care Unit: A Systematic Review.

Authors:  Kristin E Schwab; An Q To; Jennifer Chang; Bonnie Ronish; Dale M Needham; Jennifer L Martin; Biren B Kamdar
Journal:  J Intensive Care Med       Date:  2019-07-22       Impact factor: 2.889

3.  Comparison between Electrocardiographic and Earlobe Pulse Photoplethysmographic Detection for Evaluating Heart Rate Variability in Healthy Subjects in Short- and Long-Term Recordings.

Authors:  Basilio Vescio; Maria Salsone; Antonio Gambardella; Aldo Quattrone
Journal:  Sensors (Basel)       Date:  2018-03-13       Impact factor: 3.576

4.  A Real-Time PPG Peak Detection Method for Accurate Determination of Heart Rate during Sinus Rhythm and Cardiac Arrhythmia.

Authors:  Dong Han; Syed Khairul Bashar; Jesús Lázaro; Fahimeh Mohagheghian; Andrew Peitzsch; Nishat Nishita; Eric Ding; Emily L Dickson; Danielle DiMezza; Jessica Scott; Cody Whitcomb; Timothy P Fitzgibbons; David D McManus; Ki H Chon
Journal:  Biosensors (Basel)       Date:  2022-01-29

5.  Wearable sensors for prediction of intraamniotic infection in women with preterm premature rupture of membranes: a prospective proof of principle study.

Authors:  Romana Brun; Julia Girsberger; Martina Rothenbühler; Catrin Argyle; Juliane Hutmacher; Christian Haslinger; Brigitte Leeners
Journal:  Arch Gynecol Obstet       Date:  2022-09-13       Impact factor: 2.493

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.