Literature DB >> 24093076

Salvaging the pullout strength of stripped screws in osteoporotic bone.

Pierre H M Pechon1, Simon C Mears, Evan R Langdale, Stephen M Belkoff.   

Abstract

Our goal was to determine whether the pullout strength of stripped screw holes in osteoporotic bone could be increased with readily available materials from the operating room. We inserted 3.5-mm stainless steel nonlocking self-tapping cortical screws bicortically into 5 osteoporotic humeri. Each screw was first stripped by rotating it 1 full turn past maximum torque. In the control group, the screw was pulled out using an MTS machine (858; MTS Inc, Eden Prairie, Minnesota). In the treatment groups, the screw was removed, the hole was augmented with 1 of the 3 materials (stainless steel wire, polysorb suture, or polyethylene terephthalate glycol plastic sheet), and the screws were replaced and then pulled out. The effect of material on pullout strength was checked for significance (P < .05) using a general linearized latent and mixed model (Stata10; StataCorp, College Station, Texas). The mean (95% confidence interval) pullout strength for the unaugmented hole was 138 N (range 88-189), whereas the holes augmented with plastic, suture, or wire had mean pullout strengths of 255 N (range 177-333), 228 N (range 149-308), and 396 N (range 244-548), respectively. Although wire augmentation resulted in pullout strength that was significantly greater than that of the unaugmented screw, it was still below that of the intact construct.

Entities:  

Keywords:  ankle fracture; bone density; humerus fracture; inadvertent stripping; osteoporosis; screw stripping

Year:  2013        PMID: 24093076      PMCID: PMC3789504          DOI: 10.1177/2151458513498393

Source DB:  PubMed          Journal:  Geriatr Orthop Surg Rehabil        ISSN: 2151-4585


  6 in total

Review 1.  Bioabsorbable implants in orthopaedics: new developments and clinical applications.

Authors:  W J Ciccone; C Motz; C Bentley; J P Tasto
Journal:  J Am Acad Orthop Surg       Date:  2001 Sep-Oct       Impact factor: 3.020

2.  Mechanical evaluation of a 4-mm cancellous "rescue" screw in osteoporotic cortical bone: a cadaveric study.

Authors:  Simon J Wall; Sandeep P Soin; Trevor A Knight; Simon C Mears; Stephen M Belkoff
Journal:  J Orthop Trauma       Date:  2010-06       Impact factor: 2.512

3.  Effects of surgical errors on small fragment screw fixation.

Authors:  Cory Collinge; Brian Hartigan; Eugene P Lautenschlager
Journal:  J Orthop Trauma       Date:  2006-07       Impact factor: 2.512

4.  Inadvertent screw stripping during ankle fracture fixation in elderly bone.

Authors:  A Feroz Dinah; Simon C Mears; Trevor A Knight; Sandeep P Soin; John T Campbell; Stephen M Belkoff
Journal:  Geriatr Orthop Surg Rehabil       Date:  2011-05

5.  Does maximum torque mean optimal pullout strength of screws?

Authors:  Sara E Tankard; Simon C Mears; Daniel Marsland; Evan R Langdale; Stephen M Belkoff
Journal:  J Orthop Trauma       Date:  2013-04       Impact factor: 2.512

6.  Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method.

Authors:  Susan M Renner; Tae-Hong Lim; Whoan-Jeang Kim; Leonid Katolik; Howard S An; Gunnar B J Andersson
Journal:  Spine (Phila Pa 1976)       Date:  2004-06-01       Impact factor: 3.468

  6 in total
  3 in total

1.  Can high-friction intraannular material increase screw pullout strength in osteoporotic bone?

Authors:  Daniel Bronsnick; Ryan E Harold; Ari Youderian; Giovanni Solitro; Farid Amirouche; Benjamin Goldberg
Journal:  Clin Orthop Relat Res       Date:  2014-10-02       Impact factor: 4.176

Review 2.  Management of Osteoporotic and Neuropathic Ankle Fractures in the Elderly.

Authors:  P Hoogervorst; Cja Van Bergen; Mpj Van den Bekerom
Journal:  Curr Geriatr Rep       Date:  2017-02-03

3.  Dual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time.

Authors:  Brian B Gilmer; Sarah D Lang
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-09-25
  3 in total