The effect of excision of the radial head and metallic radial head replacement on the tension in the interosseous membrane.

B A Lanting1, L M Ferreira, J A Johnson, G S Athwal, G J W King.   

Abstract

We measured the tension in the interosseous membrane in six cadaveric forearms using an in vitro forearm testing system with the native radial head, after excision of the radial head and after metallic radial head replacement. The tension almost doubled after excision of the radial head during simulated rotation of the forearm (p = 0.007). There was no significant difference in tension in the interosseous membrane between the native and radial head replacement states (p = 0.09). Maximal tension occurred in neutral rotation with both the native and the replaced radial head, but in pronation if the radial head was excised. Under an increasing axial load and with the forearm in a fixed position, the rate of increase in tension in the interosseous membrane was greater when the radial head was excised than for the native radial head or replacement states (p = 0.02). As there was no difference in tension between the native and radial head replacement states, a radial head replacement should provide a normal healing environment for the interosseous membrane after injury or following its reconstruction. Load sharing between the radius and ulna becomes normal after radial head Replacement. As excision of the radial head significantly increased the tension in the interosseous membrane it may potentially lead to its attritional failure over time.

Entities:  

Keywords:  Interosseous membrane; Radial head arthroplasty; Radial head excision; Radial head fracture; Radial head replacement

Mesh:

Substances:

Year:  2013        PMID: 24078536     DOI: 10.1302/0301-620X.95B10.31844

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  6 in total

1.  Disadvantages of having a shortening of the proximal radius.

Authors:  Nick F J Hilgersom; Denise Eygendaal; Michel P J van den Bekerom
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-20       Impact factor: 4.342

Review 2.  Longitudinal instability of the forearm.

Authors:  J Phadnis; A C Watts
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

3.  Operative Management of Unstable Radial Head Fractures in a Young Active Population.

Authors:  Nicholas Kusnezov; Emmanuel Eisenstein; John C Dunn; Austin Fares; Justin Mitchell; Kelly Kilcoyne; Brian R Waterman
Journal:  Hand (N Y)       Date:  2017-06-27

4.  Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF.

Authors:  Marc Schnetzke; Sara Aytac; Moritz Deuss; Stefan Studier-Fischer; Benedict Swartman; Matthias Muenzberg; Paul-Alfred Gruetzner; Thorsten Guehring
Journal:  Int Orthop       Date:  2014-08-02       Impact factor: 3.075

5.  Neglected Type I Monteggia Fracture Dislocation in Adult.

Authors:  Archit Agarwal; Inder Pawar
Journal:  J Clin Diagn Res       Date:  2017-08-01

6.  Forearm Interosseous Membrane Maintains the Stability of Proximal Radioulnar Joint.

Authors:  Ning Zhang; Jia-Hu Fang
Journal:  Orthop Surg       Date:  2020-12-21       Impact factor: 2.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.