Literature DB >> 24077662

Evaluation of magnetic resonance imaging issues for implantable microfabricated magnetic actuators.

Hyowon Lee, Qing Xu, Frank G Shellock, Marvin Bergsneider, Jack W Judy.   

Abstract

The mechanical robustness of microfabricated torsional magnetic actuators in withstanding the strong static fields (7 T) and time-varying field gradients (17 T/m) produced by an MR system was studied in this investigation. The static and dynamic mechanical characteristics of 30 devices were quantitatively measured before and after exposure to both strong uniform and non-uniform magnetic fields. The results showed no statistically significant change in both the static and dynamic mechanical performance, which mitigate concerns about the mechanical stability of these devices in association with MR systems under the conditions used for this assessment. The MR-induced heating was also measured in a 3-T/128-MHz MR system. The results showed a minimal increase (1.6 °C) in temperature due to the presence of the magnetic microactuator array. Finally, the size of the MR-image artifacts created by the magnetic microdevices were quantified. The signal loss caused by the devices was approximately four times greater than the size of the device.

Entities:  

Mesh:

Year:  2014        PMID: 24077662      PMCID: PMC3969409          DOI: 10.1007/s10544-013-9815-3

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  15 in total

Review 1.  Microrobots for minimally invasive medicine.

Authors:  Bradley J Nelson; Ioannis K Kaliakatsos; Jake J Abbott
Journal:  Annu Rev Biomed Eng       Date:  2010-08-15       Impact factor: 9.590

Review 2.  Artificial bacterial flagella for micromanipulation.

Authors:  Li Zhang; Kathrin E Peyer; Bradley J Nelson
Journal:  Lab Chip       Date:  2010-06-21       Impact factor: 6.799

3.  Detachable coil for cerebral aneurysms: in vitro evaluation of magnetic field interactions, heating, and artifacts at 3T.

Authors:  Frank G Shellock; Matthew Gounis; Ajay Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

4.  Effect of 3T MRI on the function of shunt valves--evaluation of Paedi GAV, Dual Switch and proGAV.

Authors:  D Lindner; C Preul; C Trantakis; H Moeller; J Meixensberger
Journal:  Eur J Radiol       Date:  2005-10       Impact factor: 3.528

5.  A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane.

Authors:  Bazhang Yu; Nathan Long; Yvonne Moussy; Francis Moussy
Journal:  Biosens Bioelectron       Date:  2005-12-05       Impact factor: 10.618

6.  Programmable CSF shunt valve: in vitro assessment of MR imaging safety at 3T.

Authors:  F G Shellock; R Habibi; J Knebel
Journal:  AJNR Am J Neuroradiol       Date:  2006-03       Impact factor: 3.825

7.  Magnetically programmable shunt valve: MRI at 3-Tesla.

Authors:  Frank G Shellock; Stephen F Wilson; Christophe P Mauge
Journal:  Magn Reson Imaging       Date:  2007-01-19       Impact factor: 2.546

8.  Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs).

Authors:  Abdur Rub Abdur Rahman; Gusphyl Justin; Anthony Guiseppi-Elie
Journal:  Biomed Microdevices       Date:  2009-02       Impact factor: 2.838

9.  A Parylene MEMS Electrothermal Valve.

Authors:  Po-Ying Li; Tina K Givrad; Daniel P Holschneider; Jean-Michel I Maarek; Ellis Meng
Journal:  J Microelectromech Syst       Date:  2009-12       Impact factor: 2.417

10.  Thin film nitinol microstent for aneurysm occlusion.

Authors:  Youngjae Chun; Daniel S Levi; K P Mohanchandra; Fernando Vinuela; Fernando Vinuela; Gregory P Carman
Journal:  J Biomech Eng       Date:  2009-05       Impact factor: 2.097

View more
  6 in total

1.  Low-cost rapid prototyping of liquid crystal polymer based magnetic microactuators for glaucoma drainage devices.

Authors:  Simon John
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

2.  Polyimide-based magnetic microactuators for biofouling removal.

Authors:  Jacob Miller; Jeffrey F Rhoads; Jacqueline Linnes
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

3.  Anti-biofouling implantable catheter using thin-film magnetic microactuators.

Authors:  Qi Yang; Hyunsu Park; Tran N H Nguyen; Jeffrey F Rhoads; Albert Lee; R Timothy Bentley; Jack W Judy; Hyowon Lee
Journal:  Sens Actuators B Chem       Date:  2018-07-24       Impact factor: 7.460

4.  Piezoresistor-Embedded Multifunctional Magnetic Microactuators for Implantable Self-Clearing Catheter.

Authors:  Qi Yang; Albert Lee; R Timothy Bentley; Hyowon Lee
Journal:  IEEE Sens J       Date:  2019-02-15       Impact factor: 3.301

5.  Mechanical Evaluation of Unobstructing Magnetic Microactuators for Implantable Ventricular Catheters.

Authors:  Hyowon Lee; Kameran Kolahi; Marvin Bergsneider; Jack W Judy
Journal:  J Microelectromech Syst       Date:  2014-05-16       Impact factor: 2.417

6.  Application of magnetically actuated self-clearing catheter for rapid in situ blood clot clearance in hemorrhagic stroke treatment.

Authors:  Qi Yang; Ángel Enríquez; Dillon Devathasan; Craig A Thompson; Dillan Nayee; Ryan Harris; Douglas Satoski; Barnabas Obeng-Gyasi; Albert Lee; R Timothy Bentley; Hyowon Lee
Journal:  Nat Commun       Date:  2022-01-26       Impact factor: 14.919

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.