Literature DB >> 24077338

Energy- and time-resolved detection of prompt gamma-rays for proton range verification.

Joost M Verburg1, Kent Riley, Thomas Bortfeld, Joao Seco.   

Abstract

In this work, we present experimental results of a novel prompt gamma-ray detector for proton beam range verification. The detection system features an actively shielded cerium-doped lanthanum(III) bromide scintillator, coupled to a digital data acquisition system. The acquisition was synchronized to the cyclotron radio frequency to separate the prompt gamma-ray signals from the later-arriving neutron-induced background. We designed the detector to provide a high energy resolution and an effective reduction of background events, enabling discrete proton-induced prompt gamma lines to be resolved. Measuring discrete prompt gamma lines has several benefits for range verification. As the discrete energies correspond to specific nuclear transitions, the magnitudes of the different gamma lines have unique correlations with the proton energy and can be directly related to nuclear reaction cross sections. The quantification of discrete gamma lines also enables elemental analysis of tissue in the beam path, providing a better prediction of prompt gamma-ray yields. We present the results of experiments in which a water phantom was irradiated with proton pencil-beams in a clinical proton therapy gantry. A slit collimator was used to collimate the prompt gamma-rays, and measurements were performed at 27 positions along the path of proton beams with ranges of 9, 16 and 23 g cm(-2) in water. The magnitudes of discrete gamma lines at 4.44, 5.2 and 6.13 MeV were quantified. The prompt gamma lines were found to be clearly resolved in dimensions of energy and time, and had a reproducible correlation with the proton depth-dose curve. We conclude that the measurement of discrete prompt gamma-rays for in vivo range verification of clinical proton beams is feasible, and plan to further study methods and detector designs for clinical use.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24077338     DOI: 10.1088/0031-9155/58/20/L37

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Intensity modulated proton therapy.

Authors:  H M Kooy; C Grassberger
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

Review 2.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

3.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

4.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

5.  3D prompt gamma imaging for proton beam range verification.

Authors:  E Draeger; D Mackin; S Peterson; H Chen; S Avery; S Beddar; J C Polf
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

6.  Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient.

Authors:  Jerimy C Polf; Dennis Mackin; Eunsin Lee; Stephen Avery; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

7.  Secondary Particle Interactions in a Compton Camera Designed for in vivo Range Verification of Proton Therapy.

Authors:  Rajesh Panthi; Paul Maggi; Stephen Peterson; Dennis Mackin; Jerimy Polf; Sam Beddar
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-10-12

8.  Inter-patient variations of radiation-induced normal-tissue changes in Gd-EOB-DTPA-enhanced hepatic MRI scans during fractionated proton therapy.

Authors:  Christian Richter; Ovidiu C Andronesi; Ronald J H Borra; Felix Voigt; Steffen Löck; Dan G Duda; Alexander R Guimaraes; Theodore S Hong; Thomas R Bortfeld; Joao Seco
Journal:  Clin Transl Radiat Oncol       Date:  2019-04-26

Review 9.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

Review 10.  Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy.

Authors:  Fernando Hueso-González; Fine Fiedler; Christian Golnik; Thomas Kormoll; Guntram Pausch; Johannes Petzoldt; Katja E Römer; Wolfgang Enghardt
Journal:  Front Oncol       Date:  2016-04-12       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.