Literature DB >> 24075663

Load system of segmental T-loops for canine retraction.

Zeyang Xia1, Jie Chen, Feifei Jiangc, Shuning Li, Rodrigo F Viecilli, Sean Y Liu.   

Abstract

INTRODUCTION: The orthodontic load system, especially ideal moment-to-force ratios, is the commonly used design parameter of segmental T-loops for canine retraction. However, the load system, including moment-to-force ratios, can be affected by the changes in canine angulations and interbracket distances. We hypothesized that clinical changes in canine position and angulation during canine retraction will significantly affect the load system delivered to the tooth.
METHODS: The load systems of 2 T-loop groups, one for translation and the other for controlled tipping, from 9 bilateral canine retraction patients were made to the targeted values obtained from finite element analyses and validated. Each loop was tested on the corresponding maxillary dental cast obtained in the clinic. The casts were made before and after each treatment interval so that both initial and residual load systems could be obtained. The pretreatment and posttreatment interbracket distances were recorded for calculating interbracket distance changes.
RESULTS: As the interbracket distances decreased, the average retraction-force drop per interbracket distance reduction was 36 cN/mm, a 30% drop per 1 mm of interbracket distance decrease. The average antitipping-moment drops per interbracket distance reductions were 0.02 N-mm per millimeter for controlled tipping and 1.4 N-mm per millimeter for translation, about 0.6% and 17% drops per 1 mm of interbracket decrease, respectively. Consequently, the average moment-to-force ratio increases per 1 mm of interbracket distance reduction were 1.24 mm per millimeter for controlled tipping and 6.34 mm per millimeter for translation. There was a significant residual load, which could continue to move the tooth if the patient missed the next-scheduled appointment.
CONCLUSIONS: Clinical changes in canine position and angulation during canine retraction significantly affect the load system. The initial planned moment-to-force ratio needs to be lower to reach the expected average ideal value. Patients should be required to follow the office visit schedule closely to prevent negative effects because of significant moment-to-force ratios increases with time.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24075663      PMCID: PMC3829684          DOI: 10.1016/j.ajodo.2013.05.007

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  18 in total

1.  Effects of T-loop geometry on its forces and moments.

Authors:  J Chen; D L Markham; T R Katona
Journal:  Angle Orthod       Date:  2000-02       Impact factor: 2.079

2.  Auxiliary springs in continuous arch treatment: Part 1. An analytical study employing the finite-element method.

Authors:  B S Haskell; W A Spencer; M Day
Journal:  Am J Orthod Dentofacial Orthop       Date:  1990-11       Impact factor: 2.650

3.  Optimizing anterior and canine retraction.

Authors:  C J Burstone; H A Koenig
Journal:  Am J Orthod       Date:  1976-07

4.  Does the center of resistance depend on the direction of tooth movement?

Authors:  Brandon N Meyer; Jie Chen; Thomas R Katona
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-03       Impact factor: 2.650

5.  The segmented arch approach to space closure.

Authors:  C J Burstone
Journal:  Am J Orthod       Date:  1982-11

6.  Holographic determination of centers of rotation produced by orthodontic forces.

Authors:  C J Burstone; R J Pryputniewicz
Journal:  Am J Orthod       Date:  1980-04

7.  Comparison of three-dimensional orthodontic load systems of different commercial archwires for space closure.

Authors:  Steven Gajda; Jie Chen
Journal:  Angle Orthod       Date:  2011-08-31       Impact factor: 2.079

8.  Controlled retraction of maxillary incisors.

Authors:  P Gjessing
Journal:  Am J Orthod Dentofacial Orthop       Date:  1992-02       Impact factor: 2.650

9.  Testing force systems and biomechanics--measured tooth movements from differential moment closing loops.

Authors:  Andrew J Kuhlberg; Derek Priebe
Journal:  Angle Orthod       Date:  2003-06       Impact factor: 2.079

10.  Orthodontic mechanotransduction and the role of the P2X7 receptor.

Authors:  Rodrigo F Viecilli; Thomas R Katona; Jie Chen; James K Hartsfield; W Eugene Roberts
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-06       Impact factor: 2.650

View more
  9 in total

1.  Hounsfield unit change in root and alveolar bone during canine retraction.

Authors:  Feifei Jiang; Sean S-Y Liu; Zeyang Xia; Shuning Li; Jie Chen; Katherine S Kula; George Eckert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2015-04       Impact factor: 2.650

2.  Three-dimensional nonlinear prediction of tooth movement from the force system and root morphology.

Authors:  Roberto Savignano; Rodrigo F Viecilli; Udochukwu Oyoyo
Journal:  Angle Orthod       Date:  2020-11-01       Impact factor: 2.079

3.  Mechanical environment for lower canine T-loop retraction compared to en-masse space closure with a power-arm attached to either the canine bracket or the archwire.

Authors:  Feifei Jiang; W Eugene Roberts; Yanzhi Liu; Abbas Shafiee; Jie Chen
Journal:  Angle Orthod       Date:  2020-11-01       Impact factor: 2.079

4.  Mechanical environment change in root, periodontal ligament, and alveolar bone in response to two canine retraction treatment strategies.

Authors:  F Jiang; Z Xia; S Li; G Eckert; J Chen
Journal:  Orthod Craniofac Res       Date:  2015-04       Impact factor: 1.826

5.  Root resorptions associated with canine retraction treatment.

Authors:  Feifei Jiang; Jie Chen; Katherine Kula; Huiying Gu; Yansheng Du; George Eckert
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-09       Impact factor: 2.650

6.  Comparison of movement rate with different initial moment-to-force ratios.

Authors:  Shuning Li; Jie Chen; Katherine S Kula
Journal:  Am J Orthod Dentofacial Orthop       Date:  2019-08       Impact factor: 2.650

7.  Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

Authors:  Ricardo Lima Shintcovsk; Roberto Soares da Silva Júnior; Larry White; Lidia Parsekian Martins; Renato Parsekian Martins
Journal:  Angle Orthod       Date:  2018-05-15       Impact factor: 2.079

8.  Three-dimensional canine displacement patterns in response to translation and controlled tipping retraction strategies.

Authors:  Shuning Li; Zeyang Xia; Sean Shih-Yao Liu; George Eckert; Jie Chen
Journal:  Angle Orthod       Date:  2015-01       Impact factor: 2.079

9.  The T-loop in details.

Authors:  Amanda Frizzo Viecilli; Maria Perpétua Mota Freitas
Journal:  Dental Press J Orthod       Date:  2018-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.