Literature DB >> 1739066

Controlled retraction of maxillary incisors.

P Gjessing1.   

Abstract

The force characteristics inherent in the prefabricated PG retraction spring have been shown to be efficient for controlled movement of canines. In the present investigation, this spring was analyzed with regard to its applicability for controlled retraction of the maxillary incisors. A description of the required system of moments and horizontal and vertical forces, acting at both the active (alpha) and reactive (beta) units, is presented. The three-dimensional force system generated by specific modifications of the spring was registered in a bench testing device mounted with strain gauges, and the resultant data presented in a graphic. It is concluded that the PG retraction spring can be used as a module for controlled retraction of both canines and incisors. The magnitude of horizontal and vertical forces is kept within the anticipated physiologic limits and can be identified by the shape of the activated spring. Variability of the distance between the anterior and the posterior points of force attack has no significant influence on the horizontal and vertical forces produced. Only minor clinical adjustments are needed to modify the retraction spring from canine-to-incisor retraction.

Entities:  

Mesh:

Year:  1992        PMID: 1739066     DOI: 10.1016/0889-5406(92)70003-S

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  8 in total

1.  [The practical aspects of using "superelastic" arch wires in the edgewise technic].

Authors:  L Linge; S Dahm
Journal:  Fortschr Kieferorthop       Date:  1994-12

2.  [Retraction of the upper incisors with pseudoelastic treatment elements. Their computational and biomechanical testing and clinical use].

Authors:  C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1994-02

3.  Load system of segmental T-loops for canine retraction.

Authors:  Zeyang Xia; Jie Chen; Feifei Jiangc; Shuning Li; Rodrigo F Viecilli; Sean Y Liu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-10       Impact factor: 2.650

4.  Effects of first- and second-order gable bends on the orthodontic load systems produced by T-loop archwires.

Authors:  Thomas R Katona; Serkis C Isikbay; Jie Chen
Journal:  Angle Orthod       Date:  2013-08-29       Impact factor: 2.079

5.  Three-dimensional canine displacement patterns in response to translation and controlled tipping retraction strategies.

Authors:  Shuning Li; Zeyang Xia; Sean Shih-Yao Liu; George Eckert; Jie Chen
Journal:  Angle Orthod       Date:  2015-01       Impact factor: 2.079

6.  Quantification of three-dimensional orthodontic force systems of T-loop archwires.

Authors:  Jie Chen; Serkis C Isikbay; Edward J Brizendine
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

7.  Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study.

Authors:  Jae Hyun Park; Yoon-Ah Kook; Yukio Kojima; Sunock Yun; Jong-Moon Chae
Journal:  Korean J Orthod       Date:  2019-05-21       Impact factor: 1.372

8.  Dual-section versus conventional archwire for en-masse retraction of anterior teeth with direct skeletal anchorage: a finite element analysis.

Authors:  Ryo Hamanaka; Daniele Cantarella; Luca Lombardo; Lorena Karanxha; Massimo Del Fabbro; Giuseppe Siciliani; Noriaki Yoshida
Journal:  BMC Oral Health       Date:  2021-02-25       Impact factor: 2.757

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.