Literature DB >> 24075661

Quantification of patient compliance with Hawley retainers and removable functional appliances during the retention phase.

Timm Cornelius Schott1, Christoph Schlipf, Bettina Glasl, Christian L Schwarzer, Joachim Weber, Björn Ludwig.   

Abstract

INTRODUCTION: The success of retention with removable retainers is highly dependent on efficient patient compliance. The aim of this study was to quantify patient compliance with removable retainers using microelectronic wear-time documentation during the retention phase.
METHODS: One hundred patients, between 13 and 20 years of age, were retained with removable Hawley retainers and functional appliance retainers after successful multibracket treatment at the University Hospital of Tübingen, Germany, and in 4 private practices in Germany. Microsensors were incorporated into the orthodontic retainers by polymerization, and daily wear time was documented in 15-minute intervals during the retention phase for up to 15 months. Patient compliance was quantified with wear-time documentation. Additionally, the influences of age, sex, place of treatment, device type, and health insurance status on compliance were determined and statistically evaluated.
RESULTS: Most study participants complied with the prescribed wear time of 8 hours or more per day. Combined patient data indicated a median wear time of 7.0 hours per day over the evaluation period. Wear-time documentation showed either regular or irregular patterns of compliance. Initial compliance did not usually alter over the retention phase. Compliance was not influenced by device type, but age, sex, place of treatment, and insurance status produced changes in the median wear time of up to 50%.
CONCLUSIONS: Electronic wear-time documentation of patients' compliance is an easily comprehensible measurement that allows orthodontists to examine the patient's contribution to the success of retention and personalize treatment accordingly. Place of treatment and health insurance status are more closely associated with compliance than are basic patient demographics.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24075661     DOI: 10.1016/j.ajodo.2013.04.020

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Smartphone-based application for EMA assessment of awake bruxism: compliance evaluation in a sample of healthy young adults.

Authors:  Anna Colonna; Luca Lombardo; Giuseppe Siciliani; Alessandro Bracci; Luca Guarda-Nardini; Goran Djukic; Daniele Manfredini
Journal:  Clin Oral Investig       Date:  2019-10-24       Impact factor: 3.573

2.  Evaluation of relapse with thermoplastic retainers equipped with microsensors.

Authors:  Sait İshakoğlu; Serpil Çokakoğlu
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

3.  Assessment of Factors Affecting Adolescent Patients' Compliance with Hawley and Vacuum Formed Retainers.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi
Journal:  J Clin Diagn Res       Date:  2016-06-01

4.  How patient-selected colors for removable appliances are reflected in electronically tracked compliance (wear times and wear behavior).

Authors:  Timm C Schott; Dieter Menne
Journal:  Angle Orthod       Date:  2018-03-27       Impact factor: 2.079

Review 5.  Development of a clinical practice guideline for orthodontic retention.

Authors:  Cleo Wouters; Toon A Lamberts; Anne Marie Kuijpers-Jagtman; Anne Marie Renkema
Journal:  Orthod Craniofac Res       Date:  2019-03-18       Impact factor: 1.826

6.  The Use of Microsensors to Assess the Daily Wear Time of Removable Orthodontic Appliances: A Prospective Cohort Study.

Authors:  Marek Nahajowski; Joanna Lis; Michał Sarul
Journal:  Sensors (Basel)       Date:  2022-03-22       Impact factor: 3.576

7.  Orthodontic retention: what's on the horizon?

Authors:  Simon J Littlewood; Oyku Dalci; Calogero Dolce; L Shannon Holliday; Sasan Naraghi
Journal:  Br Dent J       Date:  2021-06-11       Impact factor: 1.626

8.  A feasible method to improve adherence of Hawley retainer in adolescent orthodontic patients: a randomized controlled trial.

Authors:  Feiou Lin; Hao Sun; Zhenyu Ni; Minling Zheng; Linjie Yao
Journal:  Patient Prefer Adherence       Date:  2015-10-28       Impact factor: 2.711

9.  Quantification of wear-time adherence of removable appliances in young orthodontic patients in relation to their BMI: a preliminary study.

Authors:  Timm Cornelius Schott; Björn Ludwig
Journal:  Patient Prefer Adherence       Date:  2014-11-17       Impact factor: 2.711

Review 10.  The effects of fixed and removable orthodontic retainers: a systematic review.

Authors:  Dalya Al-Moghrabi; Nikolaos Pandis; Padhraig S Fleming
Journal:  Prog Orthod       Date:  2016-07-26       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.