Literature DB >> 24071809

Mapping corneal thickness using dual-scheimpflug imaging at different stages of keratoconus.

Selim Demir1, Hüseyin Ortak, Volkan Yeter, Sait Alim, Osman Sayn, Ufuk Taş, Barş Sönmez.   

Abstract

PURPOSE: To map the thickness of the entire cornea using dual-Scheimpflug imaging and to evaluate the changes in the corneal thickness over the entire cornea at different stages of keratoconus.
METHODS: Corneal pachymetry was performed using the Galilei dual-Scheimpflug analyzer. The thinnest (TCT), central (CCT), paracentral (PaCT), and peripheral corneal thicknesses (PeCT) were also analyzed. The study examined 150 eyes of 150 patients who had myopia or myopic astigmatism and 107 eyes of 75 patients with keratoconus. Of these 107 eyes, 48 were evaluated at stage I keratoconus, 32 at stage II, 12 at stage III, and 15 at stage IV keratoconus. The level of severity of the keratoconus was based on the Amsler-Krumeich classification.
RESULTS: There were significant decreases in the thickness values of the entire corneas at all the different stages of progression defined in the Amsler-Krumeich classification. Analysis of the receiver operating characteristic curve showed that the TCT provided a better parameter than did the CCT, PaCT, and PeCT for distinguishing between keratoconus at its different stages and myopic eyes. Although the TCT and CCT parameters provided an effective distinction of eyes with stage II, III, and IV keratoconus from normal eyes, they were not effective for discriminating eyes with stage I keratoconus from eyes with myopia. But, PaCT and PeCT parameters enabled the effective discrimination between eyes with stage IV keratoconus and those with myopia only.
CONCLUSIONS: The data obtained by dual-Scheimpflug imaging for the corneal thicknesses of the entire cornea provide useful information for grading the severity of keratoconus.

Entities:  

Mesh:

Year:  2013        PMID: 24071809     DOI: 10.1097/ICO.0b013e3182a7387f

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Evaluation of Intraocular Pressure and Other Biomechanical Parameters to Distinguish between Subclinical Keratoconus and Healthy Corneas.

Authors:  Cristina Peris-Martínez; María Amparo Díez-Ajenjo; María Carmen García-Domene; María Dolores Pinazo-Durán; María José Luque-Cobija; María Ángeles Del Buey-Sayas; Susana Ortí-Navarro
Journal:  J Clin Med       Date:  2021-04-28       Impact factor: 4.241

2.  Evaluation of intereye corneal asymmetry in patients with keratoconus. A scheimpflug imaging study.

Authors:  Lóránt Dienes; Kinga Kránitz; Eva Juhász; Andrea Gyenes; Agnes Takács; Kata Miháltz; Zoltán Z Nagy; Illés Kovács
Journal:  PLoS One       Date:  2014-10-08       Impact factor: 3.240

3.  Evaluation of pachymetric measurements with scheimpflug photography-based system and optical coherence tomography pachymetry at different stages of keratoconus.

Authors:  Betül İlkay Sezgin Akçay; Engin Bilge Ozgürhan; Ercüment Bozkurt; Tuğba Kurt; Yusuf Yıldırım; Mediha Gülen Coşar; Aydın Yıldırım; Jülide Canan Umurhan Akkan; Ahmet Demirok
Journal:  J Ophthalmol       Date:  2014-07-20       Impact factor: 1.909

Review 4.  Pentacam® Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part I.

Authors:  Mahsaw N Motlagh; Majid Moshirfar; Michael S Murri; David F Skanchy; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.