Literature DB >> 24071675

Low quality evidence on the stability of orthodontic mini-implants.

Reint Meursinge Reynders1.   

Abstract

DATA SOURCES: Medline, Embase, LILACS, Cochrane Library, Google Scholar, Web of Science, African Journals Online, Digital Dissertations. STUDY SELECTION: Randomised controlled trials (RCTs), prospective controlled clinical trials(CCTs) and prospective cohort studies were included. Studies on implants with a diameter greater than 2 mm were excluded. DATA EXTRACTION AND SYNTHESIS: Data were extracted independently by two authors. Bias in RCTs was assessed using the Cochrane risk of bias tool, with non-randomised studies being assessed using the Newcastle-Ottawa Scale. Failures of mini-screw implants were expressed as event rates with 95% confidence intervals. Risk factors were assessed using random effects model and sub-group and meta-regression analyses were also conducted.
RESULTS: Fifty-two studies; five RCTs, eight CCTs, twenty-seven prospective cohort studies and twelve studies with unclear designs that were assessed to be prospective cohort studies were included. A funnel plot suggested there may be publication bias. Analysis of 4987 miniscrew implants used in 2281 patients indicated an overall failure rate of 13.5% (95% confidence interval, 11.5%-15.8%). Failures were not associated with patient sex or age and mini-screw implant insertion side, whereas they were significantly associated with jaw of insertion. Some trends were identified through exploratory analysis but no definite conclusions could be drawn.
CONCLUSIONS: Orthodontic miniscrew implants have a modest small mean failure rate, indicating their usefulness in clinical practice. Although many factors seem to affect their failure rates, the majority of them still need additional evidence to support any possible associations.

Entities:  

Mesh:

Year:  2013        PMID: 24071675     DOI: 10.1038/sj.ebd.6400950

Source DB:  PubMed          Journal:  Evid Based Dent        ISSN: 1462-0049


  5 in total

1.  Skeletal anchorage for everybody? a questionnaire study on frequency of use and clinical indications in daily practice.

Authors:  N C Bock; S Ruf
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

2.  Failure rates for stainless steel versus titanium alloy infrazygomatic crest bone screws: A single-center, randomized double-blind clinical trial.

Authors:  Chris H Chang; Joshua S Lin; W Eugene Roberts
Journal:  Angle Orthod       Date:  2018-10-29       Impact factor: 2.079

3.  Moderate quality evidence that surgical anchorage more effective than conventional anchorage during orthodontic treatment.

Authors:  Reint Meursinge Reynders; Jan de Lange
Journal:  Evid Based Dent       Date:  2014-12

4.  Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review.

Authors:  Reint Meursinge Reynders; Luisa Ladu; Laura Ronchi; Nicola Di Girolamo; Jan de Lange; Nia Roberts; Annette Plüddemann
Journal:  Syst Rev       Date:  2015-04-02

Review 5.  Barriers and facilitators to the implementation of orthodontic mini implants in clinical practice: a systematic review.

Authors:  Reint Meursinge Reynders; Laura Ronchi; Luisa Ladu; Nicola Di Girolamo; Jan de Lange; Nia Roberts; Sharon Mickan
Journal:  Syst Rev       Date:  2016-09-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.