CT pulmonary angiography using a reduced volume of high-concentration iodinated contrast medium and multiphasic injection to achieve dose reduction.

E W Goble1, J A Abdulkarim2.   

Abstract

AIM: To evaluate whether a reduced volume of a higher-concentration iodinated contrast medium delivered with a multiphasic injection could be used in computed tomography pulmonary angiography (CTPA) to achieve a reduction in dose without adversely affecting image quality.
MATERIALS AND METHODS: The CTPA images were retrospectively evaluated of 69 patients who received 100 ml of 300 mg iodine/ml ioversol, injected at constant rate of 5 ml/s and 70 patients who received 75 ml of 350 mg iodine/ml ioversol contrast medium delivered using a multiphasic injection protocol (starting at 5 ml/s and reducing exponentially). The degree of opacification in the proximal pulmonary arteries was measured in Hounsfield units.
RESULTS: The groups did not differ in terms of age, sex distribution, or weight. The mean iodine dose was lower in the 75 ml of 350 mg iodine/ml group (26.25 versus 29.5 g, p < 0.0001). Mean opacification did not differ significantly between the 75 ml of 350 mg iodine/ml and 100 ml of 300 mg iodine/ml groups in the main pulmonary artery (365 versus 331, p = 0.055) although it was significantly higher in the 75 ml group in the right (352 versus 315, p = 0.024) and left pulmonary arteries (347 versus 312, p = 0.028). Opacification correlated positively with age and negatively with weight (p < 0.001) and when these effects had been accounted for, the differences in opacification were not statistically significant in the main (p = 0.23), right (p = 0.11), or left pulmonary arteries (p = 0.13). The number of suboptimally opacified studies (opacification of less than 250 HU in main pulmonary artery) did not differ between the groups (12 versus 13, p = 0.83).
CONCLUSION: A reduction in iodine dose can be achieved without adversely affecting pulmonary arterial enhancement in CTPA by administering a smaller volume of high-concentration contrast medium using a multiphasic injection protocol.
Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24070908     DOI: 10.1016/j.crad.2013.07.023

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  7 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.

Authors:  Guang Ming Lu; Song Luo; Felix G Meinel; Andrew D McQuiston; Chang Sheng Zhou; Xiang Kong; Yan E Zhao; Ling Zheng; U Joseph Schoepf; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2014-08-07       Impact factor: 5.315

3.  High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population.

Authors:  Bastian O Sabel; Kristijan Buric; Nora Karara; Kolja M Thierfelder; Julien Dinkel; Wieland H Sommer; Felix G Meinel
Journal:  PLoS One       Date:  2016-02-12       Impact factor: 3.240

4.  Computed tomography pulmonary angiography using a 20% reduction in contrast medium dose delivered in a multiphasic injection.

Authors:  Mitchell Chen; Gaith Mattar; Jamal A Abdulkarim
Journal:  World J Radiol       Date:  2017-03-28

5.  An audit of the adequacy of contrast enhancement in CT pulmonary angiograms in a South African tertiary academic hospital setting.

Authors:  Derik J Basson; Halvani Moodley
Journal:  SA J Radiol       Date:  2022-03-24

6.  Looking beyond the thrombus: essentials of pulmonary artery imaging on CT.

Authors:  Mohammed M Khadir; Apeksha Chaturvedi; Mike S Nguyen; John C Wandtke; Susan Hobbs; Abhishek Chaturvedi
Journal:  Insights Imaging       Date:  2014-07-08

7.  Visibility and image quality of peripheral pulmonary arteries in pulmonary embolism patients using free-breathing combined with a high-threshold bolus-triggering technique in CT pulmonary angiography.

Authors:  Daliang Liu; Xiansheng Cai; Xiaoshuang Che; Yong Ma; Yucun Fu; Lin Li
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.