Literature DB >> 24065872

Predicting Adult Pulmonary Ventilation Volume and Wearing Compliance by On-Board Accelerometry During Personal Level Exposure Assessments.

C E Rodes1, S N Chillrud, W L Haskell, S S Intille, F Albinali, M Rosenberger.   

Abstract

BACKGROUND: Metabolic functions typically increase with human activity, but optimal methods to characterize activity levels for real-time predictions of ventilation volume (l/min) during exposure assessments have not been available. Could tiny, triaxial accelerometers be incorporated into personal level monitors to define periods of acceptable wearing compliance, and allow the exposures (μg/m3) to be extended to potential doses in μg/min/kg of body weight?
OBJECTIVES: In a pilot effort, we tested: 1) whether appropriately-processed accelerometer data could be utilized to predict compliance and in linear regressions to predict ventilation volumes in real time as an on-board component of personal level exposure sensor systems, and 2) whether locating the exposure monitors on the chest in the breathing zone, provided comparable accelerometric data to other locations more typically utilized (waist, thigh, wrist, etc.).
METHODS: Prototype exposure monitors from RTI International and Columbia University were worn on the chest by a pilot cohort of adults while conducting an array of scripted activities (all <10 METS), spanning common recumbent, sedentary, and ambulatory activity categories. Referee Wocket accelerometers that were placed at various body locations allowed comparison with the chest-located exposure sensor accelerometers. An Oxycon Mobile mask was used to measure oral-nasal ventilation volumes in-situ. For the subset of participants with complete data (n= 22), linear regressions were constructed (processed accelerometric variable versus ventilation rate) for each participant and exposure monitor type, and Pearson correlations computed to compare across scenarios.
RESULTS: Triaxial accelerometer data were demonstrated to be adequately sensitive indicators for predicting exposure monitor wearing compliance. Strong linear correlations (R values from 0.77 to 0.99) were observed for all participants for both exposure sensor accelerometer variables against ventilation volume for recumbent, sedentary, and ambulatory activities with MET values ~<6. The RTI monitors mean R value of 0.91 was slightly higher than the Columbia monitors mean of 0.86 due to utilizing a 20 Hz data rate instead of a slower 1 Hz rate. A nominal mean regression slope was computed for the RTI system across participants and showed a modest RSD of +/-36.6%. Comparison of the correlation values of the exposure monitors with the Wocket accelerometers at various body locations showed statistically identical regressions for all sensors at alternate hip, ankle, upper arm, thigh, and pocket locations, but not for the Wocket accelerometer located at the dominant-side wrist location (R=0.57; p=0.016).
CONCLUSIONS: Even with a modest number of adult volunteers, the consistency and linearity of regression slopes for all subjects were very good with excellent within-person Pearson correlations for the accelerometer versus ventilation volume data. Computing accelerometric standard deviations allowed good sensitivity for compliance assessments even for sedentary activities. These pilot findings supported the hypothesis that a common linear regression is likely to be usable for a wider range of adults to predict ventilation volumes from accelerometry data over a range of low to moderate energy level activities. The predicted volumes would then allow real-time estimates of potential dose, enabling more robust panel studies. The poorer correlation in predicting ventilation rate for an accelerometer located on the wrist suggested that this location should not be considered for predictions of ventilation volume.

Entities:  

Keywords:  Ventilation volume; adults; personal exposure; potential dose; triaxial accelerometry; wearing compliance

Year:  2012        PMID: 24065872      PMCID: PMC3779692          DOI: 10.1016/j.atmosenv.2012.03.057

Source DB:  PubMed          Journal:  Atmos Environ (1994)        ISSN: 1352-2310            Impact factor:   4.798


  22 in total

Review 1.  Objective measurement of physical activity in youth: current issues, future directions.

Authors:  S G Trost
Journal:  Exerc Sport Sci Rev       Date:  2001       Impact factor: 6.230

Review 2.  Measurement issues in the assessment of physical activity in children.

Authors:  G J Welk; C B Corbin; D Dale
Journal:  Res Q Exerc Sport       Date:  2000-06       Impact factor: 2.500

3.  Validation and calibration of physical activity monitors in children.

Authors:  Maurice R Puyau; Anne L Adolph; Firoz A Vohra; Nancy F Butte
Journal:  Obes Res       Date:  2002-03

4.  Effect of body size on breathing pattern and fine-particle deposition in children.

Authors:  William D Bennett; Kirby L Zeman
Journal:  J Appl Physiol (1985)       Date:  2004-04-23

Review 5.  Clinimetric review of motion sensors in children and adolescents.

Authors:  Sanne I de Vries; Ingrid Bakker; Marijke Hopman-Rock; Remy A Hirasing; Willem van Mechelen
Journal:  J Clin Epidemiol       Date:  2006-07       Impact factor: 6.437

6.  Validity and reliability of three commercially available breath-by-breath respiratory systems.

Authors:  James Carter; Asker E Jeukendrup
Journal:  Eur J Appl Physiol       Date:  2002-02-05       Impact factor: 3.078

7.  Importance of the personal endotoxin cloud in school-age children with asthma.

Authors:  Nathan Rabinovitch; Andrew H Liu; Lening Zhang; Charles E Rodes; Karin Foarde; Steven J Dutton; James R Murphy; Erwin W Gelfand
Journal:  J Allergy Clin Immunol       Date:  2005-10-10       Impact factor: 10.793

8.  Validation of a new brief physical activity survey among men and women aged 60-69 years.

Authors:  Ruth E Taylor-Piliae; Linda C Norton; William L Haskell; Mohammed H Mahbouda; Joan M Fair; Carlos Iribarren; Mark A Hlatky; Alan S Go; Stephen P Fortmann
Journal:  Am J Epidemiol       Date:  2006-07-13       Impact factor: 4.897

Review 9.  Personalized exposure assessment: promising approaches for human environmental health research.

Authors:  Brenda K Weis; David Balshaw; John R Barr; David Brown; Mark Ellisman; Paul Lioy; Gilbert Omenn; John D Potter; Martyn T Smith; Lydia Sohn; William A Suk; Susan Sumner; James Swenberg; David R Walt; Simon Watkins; Claudia Thompson; Samuel H Wilson
Journal:  Environ Health Perspect       Date:  2005-07       Impact factor: 9.031

10.  Activities Contributing to Total Energy Expenditure in the United States: Results from the NHAPS Study.

Authors:  Linda Dong; Gladys Block; Shelly Mandel
Journal:  Int J Behav Nutr Phys Act       Date:  2004-02-12       Impact factor: 6.457

View more
  16 in total

1.  Characterizing peak exposure of secondhand smoke using a real-time PM2.5 monitor.

Authors:  Ting Zhang; Steven N Chillrud; Qiang Yang; Masha Pitiranggon; James Ross; Frederica Perera; Junfeng Ji; Avrum Spira; Patrick N Breysse; Charles E Rodes; Rachel Miller; Beizhan Yan
Journal:  Indoor Air       Date:  2019-12-11       Impact factor: 5.770

2.  Laboratory Validation of Hexoskin Biometric Shirt at Rest, Submaximal Exercise, and Maximal Exercise While Riding a Stationary Bicycle.

Authors:  Cara M Smith; Steven N Chillrud; Darby W Jack; Patrick Kinney; Qiang Yang; Aimee M Layton
Journal:  J Occup Environ Med       Date:  2019-04       Impact factor: 2.162

3.  Simple to complex modeling of breathing volume using a motion sensor.

Authors:  Dinesh John; John Staudenmayer; Patty Freedson
Journal:  Sci Total Environ       Date:  2013-03-27       Impact factor: 7.963

4.  Individual exposure of graduate students to PM2.5 and black carbon in Shanghai, China.

Authors:  Xiaoning Lei; Guangli Xiu; Bo Li; Kun Zhang; Mengfei Zhao
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-11       Impact factor: 4.223

5.  Assessment of exposure to air pollution in children: Determining whether wearing a personal monitor affects physical activity.

Authors:  Stephanie Lovinsky-Desir; Jennifer Lawrence; Kyung Hwa Jung; Andrew G Rundle; Lori A Hoepner; Beizhan Yan; Federica Perera; Matthew S Perzanowski; Rachel L Miller; Steve N Chillrud
Journal:  Environ Res       Date:  2018-06-15       Impact factor: 6.498

6.  Urinary mutagenicity and other biomarkers of occupational smoke exposure of wildland firefighters and oxidative stress.

Authors:  Anna M Adetona; W. Kyle Martin; Sarah H Warren; Nancy M Hanley; Olorunfemi Adetona; Junfeng Jim Zhang; Christopher Simpson; Mike Paulsen; Stephen Rathbun; Jia-Sheng Wang; David M DeMarini; Luke P Naeher
Journal:  Inhal Toxicol       Date:  2019-04-15       Impact factor: 2.724

7.  Design and clinical feasibility of personal wearable monitor for measurement of activity and environmental exposure.

Authors:  Richard Ribón Fletcher; Nicolas M Oreskovic; Alyssa I Robinson
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

8.  Differences in Fine Particle Exposure and Estimated Pulmonary Ventilation Rate with Respect to Work Tasks of Wildland Firefighters at Prescribed Burns: A Repeated Measures Study.

Authors:  Anna M Adetona; Olorunfemi Adetona; Ryan T Chartier; Michael H Paulsen; Christopher D Simpson; Stephen L Rathbun; Luke P Naeher
Journal:  Ann Work Expo Health       Date:  2022-10-11       Impact factor: 2.779

Review 9.  New Methods for Personal Exposure Monitoring for Airborne Particles.

Authors:  Kirsten A Koehler; Thomas M Peters
Journal:  Curr Environ Health Rep       Date:  2015-12

10.  A dry powder combination of pyrazinoic acid and its n-propyl ester for aerosol administration to animals.

Authors:  P G Durham; E F Young; M S Braunstein; J T Welch; A J Hickey
Journal:  Int J Pharm       Date:  2016-04-26       Impact factor: 6.510

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.